MED288625CSENG- -  -  N- SDFL_A60_LS -N- S- S- -10/06/2025- Marine Equipment- - SN- S- - N-  - 1,075,374B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED288625CS- N-Apr 5, 20301075374
 
Form
  Marine Equipment(TO)
Certification N. MED288625CS - (ENG)
Certificate date 10/06/2025
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
SDFL_A60_LS
Applicant CARETTA SYSTEMS SA
Place of requester THESI PRARI MOUSTAKI  %  19300 Aspropyrgos  % GREECE
Tel. N.,Fax, Email 302105573694, ---, INFO@CARETTA-SYSTEMS.COM
Directive (EU) 2024/1975
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ.1319
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Request 30/05/2025
Expire date 05/04/2030
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED288625CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2024/1975.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type SDFL_A60_LS
Applicant CARETTA SYSTEMS SA
THESI PRARI MOUSTAKI,19300 Aspropyrgos,GREECE
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ.1319
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511
Issued in Genoa on
This Certificate is valid until
June 10, 2025
April 5, 2030
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED288625CS
Page 1 of 3

Product description



Double leaf sliding door whose maximum clear opening size is from minimum of 2383x2707 mm (WxH) up to maximum of 3000x5000 mm (WxH) or 5000x3000 mm (WxH). Each door leaf, having maximum dimensions from minimum of 1260x2719 mm (WxH) up to maximum of 2643x3012 mm (WxH) or 1586x5012 mm (WxH), is made of one single panel of a composite material. The panel is composed of three skins of material type NEPTUNE SHEET or type CARETTA SHEET, having nominal thickness of 2 mm each and density of 1250 kg/m3 and, in between, two layers of mineral wool (certified non-combustible in conformity to the requirements of the IMO FTP Code), 20 mm thick and having density of 160 kg/m3. Vertical stiffeners made of NEPTUNE SHEET or CARETTA SHEET are fitted, between the two skins, every 100 mm. The composite panel edge is contained within a U-shaped steel profile having dimensions of 30x48x30 mm and thickness of 1 mm. The steel sliding guide, type Helm/Niko No. 24, is fixed to the bulkhead by means of brackets 6 mm thick with maximum distance of 500 mm. The door frame, composed of steel profiles having thickness of 4 mm, is fixed to the bulkhead by means of bolts type M8x20 every 200 mm. Each leaf, on the perimeter, is fitted with intumescent strips type KERAFIX FLEXPAN 200 having section of 15x1.5 mm. The door may be equipped with a self-closing hose port.
When the clear opening size of the door is greater than 2383x2707 mm (WxH), the door shall be fitted with two automatic thermal shoot bolts per leaf on the sill and additional locking points between the two leaves. The adoption of additional locks between the two leaves is a function of the intermediate clear heights “h”, as below summarized:
  • door with maximum clear opening dimensions 3000x5000 mm (WxH):
- if 3000 ≤ h < 4000 mm an additional closing point shall be fitted
- if h≥ 4000 mm two additional closing points shall be fitted
  • door with maximum clear opening dimensions 5000x3000 mm (WxH):
- if 2600 < h ≤ 3000 mm an additional closing point shall be fitted



 



ATTACHMENT TO
CERTIFICATE No. MED288625CS
Page 2 of 3

Field of application

Fire resistant A-60 Class double leaf sliding door with the fire hazard on both sides. For doors exceeding 50% in surface area with respect to the tested doors, the installation on board has to be submitted, on a case-by-case basis, also to a full analysis based on Solas Regulation II-2/17 (alternative design).

In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- maximum door size tested
- door used with a fire tested frame design

The surfaces of this division may be fitted with products having low flame spread characteristics, installed as described in the relevant type approval certificates and satisfying the requirements of SOLAS 74 Reg. II-2 as applicable.

Reference documents

- PANMERC ENTERPRISES LTD drawing No. SDF-A60-120 Rev. A dated 3 November 2015 approved on 6 July 2016 with endorsement No. LABS-1213 and PANMERC ENTERPRISES LTD drawing No. SDF-A60-120 Rev. C dated 3 November 2015 approved on 6 July 2016 with endorsement No. LABS-1214 (tested configuration).
- PANMERC ENTERPRISES LTD drawing No. SDF-A60-LS-160 Rev. B dated 5 September 2017 approved on 18 March 2020 with endorsement No. LABS-2013 and PANMERC ENTERPRISES LTD drawing No. SDF-A60-LS-170 Rev. B dated 5 September 2017 approved on 18 March 2020 with endorsement No. LABS-2014 (enlarged configurations).

Tests carried out

- Tests as per RINA Test Laboratory reports No. 2015CS013569/3 and No. 2015CS013569/4 issued on 6 July 2016 according to IMO 2010 FTP Code Part 3.
- Increased dimensions verified with thermal-mechanical Finite Element Analysis as per RINA report No. 2020-004-MITHP Rev. 0 dated March 2020.




ATTACHMENT TO
CERTIFICATE No. MED288625CS
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****