Form
  Marine Equipment(TO)
Certification N. MED207926WS/001 - (ENG)
Certificate date 18/04/2026
Type Prevenzione dell'inquinamento marino
Product Sewage systems: (b) for use by ships, other than passenger ships, in all areas and by passenger ships outside MARPOL Annex IV special areas
Item Nº MED/2.6b

Model or Denomin.
Items
WCBx-6C~600C
Applicant WUHAN ZHONGZHOU ENVIRONMENT PROTECTION EQUIPMENT CO., LTD.
Place of requester NO.2001, THE FIRST BUILDING OF HUI GU SHI KONG WUHAN  % CHINA
Tel. N.,Fax, Email +86 27 65609668, +86 27 65609616, zhongzhou_123@163.com
Directive (EU) 2025/1533
Standards IMO Res.MEPC.227(64), not including section 4.2.
Reference Documents Annex IV Regulation 9(1) of Marpol 73/78, as amended, RINA Rules for the certification of Marine Equipment
Expire date 17/04/2031
Responsible Office SHANGHAI
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Qiang Sun S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED207926WS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Marine-Pollution prevention requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/2.6b
Description Sewage systems: (b) for use by ships, other than passenger ships, in all areas and by passenger ships outside MARPOL Annex IV special areas
Type WCBx-6C~600C
Applicant WUHAN ZHONGZHOU ENVIRONMENT PROTECTION EQUIPMENT CO., LTD.
NO.2001, THE FIRST BUILDING OF HUI GU SHI KONG WUHAN,CHINA
Testing standards IMO Res.MEPC.227(64), not including section 4.2.
Reference standards Annex IV Regulation 9(1) of Marpol 73/78, as amended, RINA Rules for the certification of Marine Equipment
Issued in SHANGHAI on
This Certificate is valid until
April 18, 2026
April 17, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Qiang Sun
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED207926WS/001
Page 1 of 5
Reference documents
  • WCBx-C Series Sewage treatment plant manufactured according to the WuHan Zhongzhou Environment Protection Equipment Co., Ltd technical specification and Drawings RINA Approved No. SHMC-10188.
  • Laboratory accreditation certificate(No.CNAS L3061 & No. CNAS L1338).
  • PONY Effluent Test Report No.:GDBYCCMG65175505Z(Sewage treatment plant) carried out by Pony Testing International Group (Shanghai) dated 17/02/2016.
  • Environmental Test Report No.:CHKS2016-0161(CWC Sewage Treatment Plant Control Box) carried out by WuHan Environment and Reliability Test Center for Mechanical and Electrical Products of China Shipbuilding Industrial Corporation dated 8/04/2016.
  • Function Test Report dated 26/01/2016.

Technical characteristics
  • WCBx-C series sewage treatment plant are designed for biological operation based on an aerobic process.
WCBx-C Series
Hydraulic loading
(m3/day)
Organic loading
(kg/day)
Suitable number of persons
WCBx-6C
0.42
0.21
6
WCBx-10C
0.70
0.35
10
WCBx-15C
1.05
0.525
15
WCBx-20C
1.40
0.70
20
WCBx-25C
1.75
0.875
25
WCBx-30C
2.10
1.05
30
WCBx-40C
2.80
1.40
40
WCBx-50C
3.50
1.75
50
WCBx-60C
4.20
2.10
60
WCBx-80C
5.60
2.80
80
WCBx-100C
7.0
3.50
100
WCBx-150C
10.5
5.25
150
WCBx-200C
14
7.0
200
WCBx-300C
21
10.5
300
WCBx-400C
28
14
400
WCBx-500C
35
17.5
500
WCBx-600C
42
21
600










ATTACHMENT TO
CERTIFICATE No. MED207926WS/001
Page 2 of 5


  • Discharge standard within the following limits:
  • Thermotolerant Coliforms (geometric mean) Less than 100 cells/100ml
    5-day Biochemical Oxygen Demand(BOD5) Less than 25Qi/Qe mg/l
    Chemical Oxygen Demand (COD) Less than 125Qi/Qe mg/l
    Total Suspended Solids (TSS) Less than 35Qi/Qe mg/l
    PH value Between 6.0 and 8.5


Fields of application
  • Each sewage treatment plant is to be supplied with it's manual for installation, use and maintenance.
  • The installation on board is to be carried out in accordance with manufacturer's instructions.
  • A copy of this EC type-examination certificate shall be carried on board any ship, equipped with the above discribed sewage treatment plant at all times.
  • Limitations and conditions of operation are imposed as follows: Inclination less than 22.5 degrees and Viabration 2 to 13.2Hz with an amplitude of plus or minus 1mm and 13.2 to 80 Hz with an acceleration of plus or minus 0.7g.

Marking of product
A plate or durable label shall be placed on the sewage treatment plant with at least the following information:
  • Manufacturer's name or logo
  • Model and serial number
  • Hydraulic loading
















ATTACHMENT TO
CERTIFICATE No. MED207926WS/001
Page 3 of 5




Testing results


Test results and details of tests conducted on samples from the sewage treatment plant in accordance with resolution MEPC.227(64), as amended:



Sewage treatment plant, Type: ....................................................................................WCBx-20C
Manufactured by: ...............................................Wuhan Zhongzhou Environment Protection Equipment Co., Ltd.
Organization conducting the test: ...............................................................Pony Testing International Group
Designed hydraulic loading: ......................................1.4..........................................m³/day
Designed organic loading: ....................................0.7............................. kg/day BOD

Number of effluent samples tested: ...................................52....................................
Number of influent samples tested: ......................................52.................................
Total suspended solids influent quality: ............. ................1398.14..............................mg/l
Total nitrogen influent quality.................................93.53.............................mg/l as nitrogen
Total phosphorus influent quality.............................29.23.......................mg/l as phosphorus

BOD5 without nitrification influent quality: ...........................1015.39...............................mg/l
Maximum hydraulic loading: ....................................1.54................................... m³/day
Minimum hydraulic loading: .....................................0.42................................... m³/day
Average hydraulic loading (Qi): ................................1.4................................... m³/day
Effluent flow (Qe):..............................................1.4............................................ m³/day
Dilution compensation factor (Qi/Qe):..........................................0.91..............................
Geometric mean of total suspended solids: .............................5.4..........................mg/l
Geometric mean of the thermotolerant coliform count:...........20........ coliforms/100 ml
Geometric mean of BOD5 without nitrification: .........................4.81........................ mg/l
Geometric mean of COD: ........................21.57........................ mg/l
Geometric mean of total nitrogen .................................1.93............................mg/l* or %*
Geometric mean of total phosphorus..............................0.93..........................mg/l* or %*
Maximum pH: .............................7.82...................
Minimum pH: ................................6.94................
Type of disinfectant used: ........................................./.............................................
If Chlorine - residual Chlorine: No
Maximum:.............................................../...................................... mg/l
Minimum: .........................................../........................................... mg/l
Geometric Mean: ............................../............................................ mg/l










ATTACHMENT TO
CERTIFICATE No. MED207926WS/001
Page 4 of 5


Was the sewage treatment plant tested with:
Fresh water flushing? ................................./............................ Yes/No*
Salt water flushing? .................................../............................. Yes/No*
Fresh and salt water flushing? ......................Yes......................... Yes/No*
Grey water added? .....................Yes.................... Yes – proportion: ....1:2......... /No*

Was the sewage treatment plant tested against the environmental conditions specified in section 5.9 of resolution MEPC.227(64):
Temperature? ..................................Yes......................................... Yes/No*
Humidity?..............................................Yes.................................... Yes/No*
Inclination? ............................................Yes.................................... Yes/No*
Vibration? ................................................Yes.................................. Yes/No*
Reliability of Electrical and Electronic Equipment? ...........Yes......... Yes/No*

Limitations and the conditions of operation are imposed:
Salinity .........................................................................................<35g/L......................................
Temperature .............................................................................as per Part 3,MEPC.107(49)
Humidity ...................................................................................as per Part 3,MEPC.107(49)
Inclination .................................................................................as per Part 3,MEPC.107(49)
Vibration ...................................................................................as per Part 3,MEPC.107(49)

Results of other parameters tested ..................................../..............................




ATTACHMENT TO
CERTIFICATE No. MED207926WS/001
Pages 5 of 5
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Qiang Sun