MED365323CS!001ENGD- -  -  N- 262JY001-00 -N- S- S- -27/11/2023- Marine Equipment- - SN- S- - N-  - 598,013B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED365323CS/001- N-Nov 26, 2028598013
 
Form
  Marine Equipment(TO)
MED283023WS/001
Certification N. MED365323CS/001 - (ENG)
Certificate date 27/11/2023
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
262JY001-00
Applicant NANJING JINGYUN SHIP FITTINGS CO., LTD.
Place of requester SHIP ACCESSORY INDUSTRY PARK, JINGQIAO TOWN, LISHUI COUNTY Nanjing  % CHINA
Tel. N.,Fax, Email 18936865198, +86 25 57401338, ---
Directive (EU) 2023/1667
Standards IMO Res. MSC.307(88)-(2010 FTP Code)
Reference Documents Chap. II-2 of SOLAS 74 Convention, as amended, RINA Rules for the certification of Marine Equipment
Request 08/10/2023
Expire date 26/11/2028
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED365323CS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2023/1667.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type 262JY001-00
Applicant NANJING JINGYUN SHIP FITTINGS CO., LTD.
SHIP ACCESSORY INDUSTRY PARK, JINGQIAO TOWN, LISHUI COUNTY Nanjing,CHINA
Testing standards IMO Res. MSC.307(88)-(2010 FTP Code)
Reference standards Chap. II-2 of SOLAS 74 Convention, as amended, RINA Rules for the certification of Marine Equipment
Issued in Genoa on
This Certificate is valid until
November 27, 2023
November 26, 2028
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED365323CS/001
Page 1 of 2

Product description

Single leaf hinged door whose maximum clear opening size is 1200 mm (W) and 2200 mm (H). The door leaf having maximum dimensions of 1271 mm (W) and 2271 mm (H) and 89.5 mm thick. The door leaf is composed, starting from the exposed side, of one steel sheet, 1.5 mm thick, a void space and one steel plate, 8 mm thick. Inside leaf are provided four steel transversal stiffeners having dimensions of 80 mm x 8 mm with ranging pitch from 392 mm up to 562 mm and two longitudinal stiffeners having the same dimensions with ranging pitch from 285 mm up to 500 mm. The door frame, welded to the bulkhead, is composed by a steel ā€œLā€ shaped profile having dimensions of 100 mm x 63 mm x 10 mm. The leaf was fitted to the frame by three steel hinges and the closure system was composed with 14 handled linkage locking device that acts on 14 dogs. On the perimeter of door leaf is provided a continuous groove of 45 mm x 20 mm to contain a gasket 45x20 mm produced by Jiangyin Dingyan Seals Co. Ltd., protected, on the exposed side, by 2 fireproof sealing strips having dimensions of 20 x 4 mm each produced by Shanghai Jiar Fu Decoration Material Co.. The leaf may be fitted with a circular window having maximum clear size of 450 mm. The pane composed by a single tempered glass, having thickness of 12 mm provided by Yixing Yushi Special Glass Co., Ltd., is held in place by means of an ā€œLā€ shaped steel frame profile dimensions 30x25 mm, fillet welded to the door steel plate and a stainless steel glass retainer having dimensions 25 x 5 mm bolted by N.20 M6x16 stainless steel bolts. Between the glass and the frame is provided a graphite fire proof strip having dimensions of 20 x 4 mm provided by Shanghai Jiar Fu Co., Ltd.
Field of application
Fire resistant A-0 Class single leaf hinged door. The bulkhead shall be insulated for 200 mm in width, all around the steel bulkhead cut door, with a certified A-60 bulkhead standard insulation.

In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf
- maximum door size tested
- door used with a fire tested frame design
Reference documents
Nanjing Jingyun Ship Fittings CO. LTD drawings reported in the Test as per FEFTC Far East Fire Testing Centre report No. FT22307 issued on 31 January 2023

Tests carried out
Test as per FEFTC Far East Fire Testing Centre report No. FT22307 issued on 31 January 2023 according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED365323CS/001
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella