ELE340626XT!002ENG- -  -  N- MGCG 0.6/1 kV -N- S- S- -14/10/2026- Prodotti Elettrici- - SN- N- - N-  - 369,823BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE340626XT/002- N-Oct 14, 2031369823
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE340626XT/002 - (ENG)
Certificate date 14/10/2026
Type Impianti Elettrici
Product CAVI ELETTRICI

Model or Denomin.
Items
MGCG 0.6/1 kV
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Place of requester MAKINE O.S.B. 6.CADDE, NO.4 DILOVASI  %  41455 KOCAELI  % TURKEY
Tel. N.,Fax, Email +90 262 722 9330, +90 262 722 9443, erdogan.malkoc@untel.com.tr
Standards DIN 89158,IEC 60092-353.
Expire date 14/10/2031
Head Office ISTANBUL
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE340626XT/002
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC CABLES
Type MGCG 0.6/1 kV
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Reference standards DIN 89158,IEC 60092-353.
  

 
 
   .   This Certificate is valid until October 14, 2031
_________________________________
RINA Services S.p.A.
Oytun Uzun
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE340626XT/002
Enclosure - Page 1 of 1
MGCG 0.6/1 kV
Materials/Components

Shipboard power cables, flame retardant, for ships and off-shore units installation.

Rated voltage: 0.6/1 kV

Type: MGCG

Marking: UNTEL DIN 89158 IEC 60092-353 MGCG n x s mm2 0.6/1 kV IEC 60332/3A


Construction:
conductor: stranded copper wire class 2 or 5, tinned on request

insulation: HEPR
bedding: rubber compound
screen: plain copper wires braid, tinned on request
sheath: CR (SE1)

Max. conductor temperature: 85°C.

In accordance to rules DIN 89158; IEC 60228 ; IEC 60092-350; IEC 60092-353; IEC 60092-360; IEC 60332-1-2; IEC 60332-3-22.


Conductor size:

number of cores 1 - cross sectional area from 1.5 to 300 mm2
number of cores 2, 3, 4 - cross sectional area from 1 to 300 mm2
number of cores 5 - cross sectional area from 1 to 240 mm2
number of cores 7 - cross sectional area from 1 to 4 mm2
number of cores 10,12,14,16, 18, 19, 20, 21, 24, 25, 27, 30, 32, 34, 36, 37 - cross sectional
area from 1 to 2.5 mm2

Technical specification: data sheet N. FR 70-061 Rev1 dated 01/07/2011.

ISTANBUL 14.10.2026
**** NOTICE: This is NOT an official certificate ****