Materials/Components
Shipboard communication, control and instrumentation cables
| Type | Characteristics |
| RFA-HF 250 V; RFA-SHF2 250 V | Halogen free with low smoke emission, flame retardant, collective tape screened cables |
| RFA-HF(i) 250 V; RFA-SHF2(i) 250 V | Halogen free with low smoke emission, flame retardant, individual and collective tape screened cables |
| RFA-FRHF 250 V; RFA-FRSHF2 250 V | Halogen free with low smoke emission, flame retardant, and fire resistant collective tape screened cables |
| RFA-FRHF(i) and RFA-FRSHF2(i) 250 V | Halogen free with low smoke emission, flame retardant and fire resistant individual and collective tape screened cables |
Construction:
| Type | Conductor | Insulation | Inner covering | Collectively screen | Sheath |
| RFA-HF 250 V; RFA-SHF2 250 V | Stranded plain or tinned annealed copper (IEC 60228 cl.2 or cl.5) | XLPE | Synthetic tape | Alluminium-polyester tape | SHF1 or SHF2 |
| RFA-HF(i) 250 V; RFA-SHF2(i) 250 V | Stranded plain annealed copper (IEC 60228 cl.2 or cl.5) | XLPE | Synthetic tape | Alluminium-polyester tape (also for individual screen) | SHF1 or SHF2 |
| RFA-FRHF 250 V; RFA-FRSHF2 250 V | Stranded plain or tinned annealed copper (IEC 60228 cl.2 or cl.5) | XLPE | Synthetic tape | Alluminium-polyester tape | SHF1 or SHF2 |
| RFA-FRHF(i) 250 V; RFA-FRSHF2(i) 250 V | Stranded plain annealed copper (IEC 60228 cl.2 or cl.5) | XLPE | Synthetic tape | Alluminium-polyester tape (also for individual screen) | SHF1 or SHF2 |
Marking: cable type - n X s mm2 - 250 V - +90°C - IEC 60092-376 - IEC 60332-3-22 - HELMACAB- month-year - lenght marking.
Note:
- Cables with conductor of IEC 60228 Class 5 shall be marked on the sheath with "cl.5"
- Cables with tinned conductor shall be marked on the sheath with "CuSn"
- Cables with SHF2 sheath shall be marked on the sheath with "RFA-SHF2", or "RFA-SHF2(i)", or "RFA-FRSHF2", or "RFA-FRSHF2(i)"
Max. conductor temperature:+90°C.
In accordance to rules IEC 60228 cl.2; IEC 60092-350; IEC 60092-376; IEC 60092-360; IEC 60332-1-2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 601034-1; IEC 61034-2; RINA Rules; RINAMIL Rules; RINA Rules for FSRU; RINAMIL for FREMM; RINA Rules for FPV.
Technical specification:
- HELMACAB SPECIFICATION HBKQ 9 spec.41_119 23.5.2025/dk (RFA-HF 250 V; RFA-SHF2 250 V)
- HELMACAB SPECIFICATION HBKQ 9 spec.40_120 23.5.2025/dk (RFA-HF(i) 250 V; RFA-SHF2(i) 250 V)
- HELMACAB SPECIFICATION HBKQ 9 spec.57_121 23.5.2025/dk (RFA-FRHF 250 V; RFA-FRSHF2 250 V)
- HELMACAB SPECIFICATION HBKQ 9 spec.58_122 23.5.2025/dk (RFA-FRHF(i) 250 and RFA-FRSHF2(i) 250 V)
Note/Remarks:
The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates. Type Approval certifies that a reppresentative sample of the products has been found to meet the applicable design criteria. Any modification of change shall not be valid until approval is granted by RINA as a result of due assessment.
Other Place of Manufacturing:
a) HELMACAB (SHANGHAI) Co., Ltd. Plot 1-2 Minghang Export Processing Zone, Shanghai, 201401 P.R.C.
b) HELMACAB Oy, Lasitehtaankatu 12, FI-10960 Hanko, Finland. |
|