Product Description
The block pressure transmitter can be used in almost all marine applications. MBS 5150 with integrated pulse snubber is for use in marine applications with severe medium influences like cavitation, liquid hammer, or pressure peaks.
The transmitters can be mounted directly on the MBV 5000 block test valve or the threaded pressure connection can be used.
The flexible pressure transmitter programme covers a 4 – 20 mA output signal, absolute or gauge (relative) versions, measuring ranges from 0 – 4 up to 0 – 400 bar.
Performance characteristics
Accuracy (incl. non-linearity, hysteresis and repeatability): ≤ ± 0.1% FS (typ.) and ≤ ± 0.3% FS (max.)
Non-linearity BFSL (conformity): ≤ ± 0.2% FS
Hysteresis and repeatability: ≤ ± 0.1% FS
Response time: For liquids with viscosity < 100 cSt < 4 ms
For air and gases (MBS 5150) < 35 ms
Overload pressure (static): 6 × FS (max. 1500 bar)
Burst pressure: 6 × FS (max. 2000 bar)
Power-up time: < 50ms
Durability, P: 10 – 90% FS: >10 × 106 cycles
MTTFd - Calculation based on the SN 29500: > 100 Years
Electrical specifications
Nom. output signal (short-circuit protected): 4 – 20 mA
Supply voltage [UB], polarity protected: 9 – 32 V DC
Supply voltage dependency: ≤ ± 0.1 % FS / 10 V
Current limitation (linear output signal up to 1.5 × rated range): 22.4 mA
Load [RL] (load connected to 0 V): RL ≤ (UB- 9 V) / 0.02 A [Ω]
Environmental conditions
Sensor temperature range: -40 – 85 °C
Media temperature range: -40 – 85 °C
Ambient temperature range (depending on electrical connection): -40 – 85 °C
Compensated temperature range: 0 – 80 °C
Transport / storage temperature range: -50 – 85 °C
EMC – Emission: EN 61000-6-3
EMC – Immunity: EN 61000-6-2
Insulation resistance: > 100 MΩ at 500 V
Vibration stability: Sinusoidal 15.9 mm-pp, 5 Hz – 25 Hz / 20 g, 25 Hz – 2 kHz - IEC 60068-2-6
Random 7.5 grms , 5 Hz – 1 kHz - IEC 60068-2-64
Shock resistance: Shock - 500 g / 1 ms - IEC 60068-2-27
Free fall - 1 m - IEC 60068-2-32
Enclosure (IP protection fulfilled together with mating connector): IP65 ( IP54 ATEX Zone 2)
Explosive atmospheres specification
Zone 2 application: II 3G / Ex ec IIA T4 Gc
Documents:
Data Sheet of Pressure Transmitter Type MBS5100 and MBS5150 - AI245286497207en-001102 dated 2025.06
Declaration of Conformity dated 25.05.2026
This certificate replaces the previous certificate ELE031621XP.