Materials/Components
Shipboard power cables, flame retardant, fire resistant, halogen free with low smoke emission, for ships and off-shore units installation.
Rated voltage: 60/250 V
Type: FM2XCH-FFR
Marking: UNTEL IEC 60092-376 FM2XCH-FFR n x s mm2 0.6/1 kV IEC 60332/3A IEC 60331
Construction:
conductor: stranded copper wire class 2 or 5, tinned on request
mica tape on the conductor
insulation: XLPE
laid up: cores laid up in pairs
separating foil
screen: plain copper braid wires, tinned on request
separating foil
sheath: SHF1
Max. conductor temperature: 90°C.
In accordance to rules IEC 60228 ; IEC 60092-350; IEC 60092-376; IEC 60092-360; IEC 60331-21; IEC 60332-1-2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2.
Conductor size:
number of cores x pairs 1,2,4,7,10,14,19,24 - cross sectional area 0.5, 0.75, 1, 1.5 mm2
Technical specification: data sheet N.FR 70-032 Rev 1 dated 01/07/2011.