Transits of metallic pipes having diameter ranging from 15 up to 108 mm through bulkheads and decks.
The transits consist of carbon steel tubular sections welded to the pipes; the pipes and the transits are insulated, when required and on the side shown in the drawings, with mineral wool having density of 100 kg/m3 and/or insulating material named MICROBIFIRE. The mineral wool consists of shaped panels (certified non combustible in conformity to the requirements of the IMO FTP Code) having thickness of 25, 50 and 60 mm and/or mineral wool cylinders (certified non combustible in conformity to the requirements of the IMO FTP Code) having thickness of 30, 40 and 70 mm. The MICROBIFIRE material, whose density is 300 kg/m3 and thickness 15 mm, may be applied in one or two layers. On the side exposed to the fire of the decks the insulating material applied on the pipes is to be fixed, when shown in the drawings, by means of steel wire net.
|
ATTACHMENT TO
CERTIFICATE Nr. MED260923CS/003
Page 2 of 4 |
Field of application
Fire resistant A Class pipe transits through decks and bulkheads having Class as described in the following tables:
Note: the transit PRESSFITTING INOX having diameter of 108 mm may be considered as transit having Class A60, if insulated with mineral wool having thickness of 70 mm and length of 500 mm (exposed side) and 1000 mm (side not exposed); the side not exposed is to be fitted, for a length of 200 mm, with a further layer of mineral wool having thickness of 50 mm.
|
ATTACHMENT TO
CERTIFICATE Nr. MED260923CS/003
Page 3 of 4 |
Reference documents
CHIBRO SpA drawings No. 2.39.189.300 (57 sheets) dated 5 June 2008, No. 2.39.189.320 (39 sheets) dated July 2009 and No. 2.39.189.600 dated 6 April 2009 (61 sheets) No. 2.39.189.660 (74 sheets), No. 2.39.189.699 and No. 2.39.189.698 approved respectively with endorsement No. LABS-155 on 22 July 2008, No. LABS-236 on 17 March 2009, No. LABS- 351 on 17 September 2009, No. LABS-358, No. LABS-359 and No. LABS-360 on 16 October 2009.
CHIBRO Spa drawings enclosed to LAPI Test report N. 1073.4IM0150/09 dated 2 October 2009.
Tests carried out
Tests as per RINA Test Laboratory Reports No. 2008CS012001 dated 22 July 2008, No. 2008CS014752 dated 30 March 2009, No. 2009CS012436 dated 17 September 2009 and No. 2009CS013911 dated 19 October 2009 issued according to IMO Resolution A. 754(18) A.IV.
LAPI Test report N. 1073.4IM0150/09 issued on 2 October 2009 according to IMO Resolution A. 754(18). |