The Fire-fighters outfit - lifeline (Type: YAJSS-I), shall be capable of being attached by means of a sister-hook to the harness of the apparatus or to a separate belt in order to prevent the breathing apparatus becoming detached when the lifeline is operated.
Design:
- Lifeline consists of steel wire (6 x 19, core 4.2 mm), of minimum 30 meters in length
- Minimum Nominal Breaking Load of at least 10 KN.
- Withstand a static proof load of at least 3.5 KN for 5 min without failure.
- It is ended by Sister Hook at each side.
Material Specification:
- Wire Rope: 304 Stainless Steel;
- Heart-Shaped Harness: 1Cr18Ni9Ti;
- Sister Hook: 1Cr18Ni9Ti
Reference Documents
The design assessment is based on IMO Res. MSC.98(73)-(FSS Code) 3 with following documents.
- Technical Specification, filed by RINA with No.: SHFP-34557;
- Technical Drawing, approved by RINA with No.: SHFP-34559;
- List of Qualified Suppliers, filed by RINA with No.: SHFP-34690;
- Daily Maintenance Manual for Lifeline, filed by RINA with No.: SHFP-36063;
- Marking, filed by RINA with No.: SHFP-36064.
Tests Carried Out
The required static load test of 3.5 KN for 5 min as per IMO Resolution MSC.98(73) Chapter 3.2.1.3 (FSS Code) was carried out under the supervision of RINA, the test report (Ref No. 2026143) is filed by RINA with No.: SHFP-36061.
Note: Material of fireman safety line (304 stainless steel) is considered as non-combustible as specified in IMO Res. MSC.61(67)-FTP Code, Annex 2, Part 1.
 | ATTACHMENT TO
CERTIFICATE No. MED797425WS
Page 2 of 3 |
Continued:
Field of Application / Limitation
Approved for use as fireproof lifelines for firefighter's outfit, for breathing apparatus approved under item MED/3.7 and item MED/7.1.
Each lifeline is to be supplied with its instructions for use, inspection and on-board maintenance complying with Regulations stated on the front page of this certificate. These instructions are to be kept on board.