ATTACHMENT TO
|
CERTIFICATE No. MED210319CS
|
|
|
|
|
|
|
|
|
|
|
|
|
| Place of unit verification |
|
|
|
| Ancona,, |
|
|
|
Verified components of the equipment (with serial
number) |
|
|
|
M01053-MS [Intended for ME; onboard IMO No. 9059107] |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
ELET-21370 approed on 21 Aug 2019 "P&ID" - 2780_0002_01_00_. PPVT-32395 approved on 29 Sep 2019 "EGCS Technical Manual - Scheme B" - ETM-B Rev 1 M01. PPVT-32087 approved on 26 Jul 2019 "Record Book" - EGC Record Book. PPVT-32082 approved on 26 Jul 2019 "OMM Rev 1" - OMM Rev 1 M0105 PPVT-32081 approved on 26 Jul 2019 "SECP Rev " - SECP Rev 0 M010. - - - - - - - - - - - - - ECG System verified components as per above documentation. - - - - - - - - - - - - - Tests carried out: EGCS Statutory Survey Report, doc. No. 2019/CS/01/2103. RINA job. ID. RS/2019/CS/01/2103
|
Limitation on the acceptance or use of the
product
In scheme B, according to MEPC.259(68), compliance with emission requirements is demonstrated by
continuous exhaust gas monitoring.
EGCS acceptance and use to be within the terms and conditions of PPVT-32081 approved on 26 July 2019 : “SOx Emissions Compliance Plan” .
Monitoring system is subject to periodic surveys by RINA according to MEPC.259(68).
____________________________ |
|
|
General condition of approval
a) This certificate will not be valid if the manufacturer or user makes any modification to the equipment, which has not been notified to, and agreed with RINA |
|
|
|