| Bulkhead having maximum dimensions of 2000 (W) mm x 2160 (H) mm and thickness of 27 mm composed of panels having maximum dimensions of 600 mm (W) x 1960 mm (H). The bulkhead is fitted, in the bottom, with a C shaped steel profile, 2 mm thick and having dimensions of 2000 (W) mm x 200 (H) mm, provided with two holes having diameter of 120 mm and pitch 1000 mm. The panels and the C shaped profile are insulated with one layer of mineral wool with glass fiber cloth type Paroc Fire Slab D180 + N5, 25 mm thick and having density of 180 kg/m3. The panel joints are composed of steel profiles, 0.8 mm thick and having length of 80 mm, with bent edges and screwed (screws 4.8x22 mm and pitch 330 mm) to “omega” shaped steel profiles, 1 mm thick and having length of 88 mm filled with the same mineral wool. The bulkhead is fitted, on the vertical edges and on the upper edge, with C and L shaped steel profiles 1 mm thick, screwed to the steel bulkhead (screws 4.8x22 mm and pitch 330 mm); on the bottom, the bulkhead is screwed to the C shaped steel profile on the joints. Field of application Fire resisting B-0 Class bulkhead with fire hazard on the side fitted with the omega shaped steel profiles.
The bulkhead is to be installed with the untested side adjacent to the untested side of another B Class bulkhead ensuring that the level of protection indicated in the relevant fire integrity tables included in SOLAS Chapter II-2/Reg. 9.2 Thermal and Structural Boundaries is always fulfilled. Reference documents Santarossa SpA drawing No. 24PC00168 Rev. 1 dated 8 January 2009 approved on 15 January 2009 with endorsement No. LABS-207.
Tests carried out Tests as per RINA Test Laboratory report No. 2008CS015842/3 issued on 26 January 2009 according to Resolution IMO A.754(18). |