E-ACT-MB Motherboard
The Motherboard can hold up to 8 E-ACT_VCU cards, thus controlling up to 8 valves.
Each E-ACT_MB is equipped with following main connections: redundant power supply 24Vdc, redundant Serial communication bus RS485, 230Vac power suplly external users.
E-ACT-VCU digital valve control cards
Each E_ACT_VCU card controls one single valve and its feedback and interconnects with the IAS (integrated automation system) via communication cards or, optionally, directly through a Hardwired interface. All the inputs are optoisolated.
A number of LEDs on the Front Panel and others visible sideways, report the operating status of the card.
Every card can be controlled locally via 3 simple push-buttons.
- Local / Remote push button is used for set in control the E-ACT-VCU. This pushbutton enables Close and Open pushbutton
- Close push button is used for a full close command on E-ACT-VCU (if Local / Remote LED is lit)
- Open push button is used for a full open command on E-ACT-VCU (if Local / Remote LED is lit)
Alarm list: two feedbacks active at the same time; E-ACT failure (excessive repositioning alarms); Calibration failure; Loss of feedback; Closing fly-time; Opening fly-time; Feedback lost; Feedback over 100%; Feedback under 0%; 230Vac missing; 24Vdc Main missing; 24Vdc Backup missing; ESD loop failure; Valve locked;
SMART-MCUR-MB-0 Motherboard has 8 slots and it is possible to connect:
8 SMART-MCUR-I/O-0 cards and 8 SMART-MCUR-COI/O-0
The motherboard is equipped with the following main connections; redundant power supply 24Vdc, 230Vac power supply for external users, redundant Serial communication bus RS485, 16 ESD monitored DI, 2 DO 230Vac for each card (CMD1-CMD8), 8 Feedback terminal block
SMART-MCUR-I/0-0 mother interface is an I/O card for the control of motors, actuators, general inductive and resistive load and is mainly provided with:
Redundant 24Vdc power supply; Auxliary input/output inteface consisting of 3 DI (free contacts) and 4 DO (with ext. 24Vdc)
Serial Communication bus RS485
All the inputs are optoisolated; Output are made with opto-mos relay current limited (150mA per output)
SMART-MCUR-COI/O-0 is a signal transducer card connected to the I/O of the SMART-MCUR-MB-0 motherboard
SMART-MCUR-COI/O-0 takes 230Vac from the motherboard and convert it to N.o. free contact or N.C. / N.o. free contact.
The external inputs 230Vac are isolated and protected by opto-isolators , internal fuse and Varistor for overvoltage protection.
The following I/O' are provided: two Digital Inputs (230Vac); Analog input 4-20 mA; two Digital output N.O. and N.C./N.O.
Reference Documents:
E-ACT-VCU Technical Manual Revision 15 (28/07/2025s)
SMART-MCUR-I/O Technical Manual Revision 2 (28/07/2025)
Test Reports:
TesLab Test Report N. 185115F (12.09.2018)
Performance tests Schedule used in report N. 185115F
General Remarks:
Installation and use to be in accordance with the Manufacturer instruction.
This Certificate annuls and replaces the previous No. ELE152518CS
Offer No. 2025/25176 - Job: RS/2025/CS/01/4478
The documents above mentioned have been archived in the Leonardo Draw Plus portal under the project:
https://leodrawplus.rina.org/projects/69621/detail.
Validity of this certificate is subject to satisfactory outcome of yearly audit as per RINA " Rules for Testing and Certification of Marine Materials and Equipment".
|
|