1. Product Description
The RKMC-2021GDS is a Gas Detection System designed to monitoring the leakage of combustible gas on board. covers the following components:
1.1 Control Panel:
Power supply: AC 220V, 50/60Hz
Structure: Wall mounting type
Main Compositions: Touch screen, Control unit, Communication convert card
IP degree: IP 44
1.2 Sampling Panel for Pump Room:
Measuring gas: Combustible gas (HC)
Measuring range: 0-100% LEL(HC), detail can refer to the certificate of gas detector
Sampling type: Scanning type continuously
Power supply: AC 220V, 50/60Hz (From control panel
IP degree: IP 44
1.3. Sampling Panel for Water Ballast Tank:
Measuring gas: Combustible gas (HC)
Measuring range: 0-100% LEL(HC), detail can refer to the certificate of gas detector
Sampling type: Scanning type continuously
Power supply: AC 220V, 50/60Hz (From control panel)
IP degree: IP 44
1.4: Detectors:
SD-1RI : HC detector head, Certified by MEDB00004SY, II 2G Ex db IIC T6 Gb
SD-1GP: HC detector head, Certified by MED 38435/BO MED, II 2G Ex d IIC T5 Gb
 | ATTACHMENT TO
CERTIFICATE No. MED485723WS
Page 2 of 3 |
2. Application/Limitation
The gas detection system designed to detects and monitors the combustible gas at the hazardous area, pump room, water ballast tank, engine room, accommodation area, cargo motor room and BOG pip duct in ships.
This certificate only covers hardware listed under product description. All changes in software are to be recorded as long as he system is used on board. Documentation of major changers is to be forwarded to us for evaluation before implemented on board.
Salt mist test is not carried out, the equipment is not to be installed in weather exposed areas. Otherwise, relevant individual test report or valid certificates are to be provided when installed on board.
3. Design Assessment
The design assessment is based on SOLAS 74 Reg. II-2/4, IMO Res. MSC.98(73)-(FSS Code) 16, IMO MSC.1/Circ.1370, IMO MSC.1/Circ.1527.
4. Tests Carried Out
Test report according to EN IEC 60079-0:2018 incl. AC:2020, EN 60079-29-1:2016, IEC 60092-504:2016, IEC 60533:2015.. Filed by RINA with drawing No. SHEL-19042.
Inspection report (Date on 2024, Apirl 25) edit by "RKMC-2021GDS " and witnessed by RINA Surveyor. Filed by RINA with drawing SHEL-19175.
5. Reference DocumentsAnalysis and assessment of risk, Filed by RINA with drawing No. SHEL-19040.
European Representative Authorization Letter. Filed by RINA with drawing No.SHEL-19032.
Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-19041.
Technical drawings and manuals approved and filed by RINA listed on Approval letter No.: SHEL/2024/382/ZHITA and SHEL/2024/432/ZHITA.