The HiMSEN engine control system HiMECS-AE is designed for control and monitoring variant type of engine that is classified in DF-GA (Gaseous fuel Admission), DF-LI (Liquid fuel Injection) and Diesel (FA: Fuel Actuator / EFI: Electronic Fuel Injection).
Main Component :
Panel | Components | Manufacturer | Type | Software | Version |
LOP | Main Control Unit | AVAT | CPU-4M (PLC) | Systembase / AVAT | 01.000.023 / 2.3.4 or upwards |
Engine Safety Unit | AVAT | IOC-4M (PLC) | Zerberus / AVAT | 3.6.0 / 1.4.0 or upwards |
Display Unit | Beijer Electronics | X3 Marine 12 inches (Touch display) | OS3 / HHI | 1.1 /1.0.2 or upwards |
IOS_M | IO Unit Main | AVAT | IOC-4M (PLC) | Zerberus / AVAT | 3.6.0 / 1.4.1 or upwards |
IOS_N | IO Unit N | AVAT | IOC-4M (PLC) | Zerberus / AVAT | 3.6.0 / 1.4.1 or upwards |
ACP | IO Unit ACP | AVAT | IOC-4M (PLC) | Zerberus / AVAT | 3.6.0 / 1.4.1 or upwards |
Net Segmenter | Phoenix Contact | FL SWITCH 2208 (Industrial Managed Ethernet Switch) | FL_NAT_2000_V3 | 3.2.1 or upwards |
Loosely Supply | Net Manager | Phoenix Contact | FL SWITCH 2208 (Industrial Managed Ethernet Switch) | FL_NAT_2000_V3 | 3.2.1 or upwards |
| ICM
(Injection Control Module) | Woodward | LECM | 5418-8001 | F52 or upwards |
CMM
(Combustion Monitoring Module) | AVAT | E2PRECON-B10 | HHP | 317 or upwards |
| E2Service | AVAT | Service Software | E2Service / Windows | 9.5.3 / 10 or upwards |
# Versions are subject to change.
Testing
The testing of security capabilities for the HiMSEN engine control system has been carried out in a Simulation environment
developed by HD Hyundai Heavy Industries Co., Ltd., in compliance with RINA Rules and IACS UR E27.
There is no network communication to untrusted networks, and the test program includes the following security capabilities:
No. | Security capabilities | No. | Security capabilities |
1 | Human user identification and authentication | 16 | Timestamps |
2 | Account management | 17 | Communication integrity |
3 | Identifier management | 18 | Malicious code protection |
4 | Authenticator management | 19 | Security functionality verification |
5 | Wireless access management
(Not Applicable) | 20 | Deterministic output |
6 | Strength of password-based authentication | 21 | Information confidentiality |
7 | Authenticator feedback | 22 | Use of cryptography |
8 | Authorization enforcement | 23 | Audit log accessibility |
9 | Wireless use control
(Not Applicable) | 24 | Denial of service protection |
10 | Use control for portable and mobile devices | 25 | Resource management |
11 | Mobile code | 26 | System backup |
12 | Session lock | 27 | System recovery and reconstitution |
13 | Auditable events | 28 | Alternative power source |
14 | Audit storage capacity | 29 | Network and security configuration settings |
15 | Response to audit processing failures | 30 | Least Functionality |
Reference Documents
- HiMECS-AE Asset Inventory Rev. 0, Doc. No. K2J025/HJK/1015 dated February 2026
- HiMECS-AE System Topology Diagram Rev.0. Doc. No. K2J025/HJK/1121 dated February 2026
- HiMECS-AE Security Capability Description Rev.1, Doc. No. K2J025/HJK/1020 dated April 2026
- HiMECS-AE Test Procedure Rev.1, Doc. No. K2J025/HJK/1201 dated April 2026
- HiMECS-AE Secure Development Lifecycle Description Rev.0, Doc. No. K2J025/HJK/1215 dated February 2026
- HiMECS-AE Security Configuration Guidance Rev.0, Doc. No. K2J025/HJK/1104 dated February 2026
- HiMECS-AE Maintenance & Verification plan Rev.0. Doc. No. K2J025/LNH/1031 dated February 2026
- HiMECS-AE Incident Response and Recovery Plan Rev.0, Doc. No. K2J026/CYM/0226 dated February 2026
- HiMECS-AE Change Management Procedure Rev. 0, Doc. No. K2J025/JCH/1215 dated December 2025
- HiMECS-AE Environmental Compliance Rev. 01, Doc. No. K2J0256/JCH/0421 dated May 2026
Test Report
- Cybersecurity Capability Demonstration Test Report Ref. No. K2J025/ZHJ/1201 Rev.1 witnessed by RINA Surveyor dated 24 April 2026
- The above documents and reports are archived in LD + with drawing no. PUEL-14932~14941: Letter ref. no. PUEL/2026/232/HK003 dated 17 April 2026
Note/Remark
- The product is always subject to compliance with RINA Rules and other Standards mentioned on certificate.
- The validity of this Certificate is subject to maintenance of the initial product conditions verified by RINA Services.
- Changes to the initial conditions must be communicated to RINA Services, which reserves the right to carry out further verification activity to confirm the validity of this Certificate.
- The rules, surveys and activities carried out by RINA, reports, certificates and other documents issued by RINA
are in no way intended to replace the duties and responsibilities of other parties such as Governments, designers,
ship builders, manufacturers, repairers, suppliers, contractors or sub-contractors, owners, operators, charterers,
underwriters, sellers or intended buyers of a ship or other product or system surveyed.
- For each installation on board, based on the ship’s configuration, the following documents are to be submitted to this Society in compliance with Chapter 5 of RINA Rules Pt C, Ch 3, Sec 5 “Cyber Resilience of On-board Systems and Equipment.
· CBS asset inventory
· Topology diagrams
· Cyber resilience test report |
|