ELE064026PUENG- -  -  N- HiMECS-AE -N- S- S- -20/08/2026- Prodotti Elettrici- - SN- N- - N-  - 2,377,237BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE064026PU- N-Aug 19, 20312377237
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE064026PU - (ENG)
Certificate date 20/08/2026
Type Impianti di Automazione
Product Engine Control System

Model or Denomin.
Items
HiMECS-AE
Applicant HD HYUNDAI HEAVY INDUSTRIES CO., LTD. - ENGINE & MACHINERY DIVISION
Place of requester 1000 Bangeojinsunhwando-ro, Dong-gu  %  44032 Ulsan  % REPUBLIC OF KOREA
Tel. N.,Fax, Email ---, ---, ---
Standards IACS UR E27 Rev.1 “Cyber resilience of onboard systems and equipment”, Sep 2023 / RINA Rules Part C, Chapter 3, Section 5, 2025
Expire date 19/08/2031
Responsible Office BUSAN
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE064026PU
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Engine Control System
Type HiMECS-AE
Applicant HD HYUNDAI HEAVY INDUSTRIES CO., LTD. - ENGINE & MACHINERY DIVISION
1000 Bangeojinsunhwando-ro, Dong-gu
44032 Ulsan
REPUBLIC OF KOREA
Reference standards IACS UR E27 Rev.1 “Cyber resilience of onboard systems and equipment”,/ RINA Rules (2026) Part C, Chapter 3, Section 5
  

 
 
   .   This Certificate is valid until August 19, 2031
_________________________________
RINA Services S.p.A.
Kyu-Oh Choi
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE064026PU
Enclosure - Page 1 of 1
HiMECS-AE

General information

The HiMSEN engine control system HiMECS-AE is designed for control and monitoring variant type of engine that is classified in DF-GA (Gaseous fuel Admission), DF-LI (Liquid fuel Injection) and Diesel (FA: Fuel Actuator / EFI: Electronic Fuel Injection).


Main Component :

Panel
Components
Manufacturer
Type
Software
Version
LOP
Main Control Unit
AVAT
CPU-4M (PLC)
Systembase / AVAT
01.000.023 / 2.3.4 or upwards
Engine Safety Unit
AVAT
IOC-4M (PLC)
Zerberus / AVAT
3.6.0 / 1.4.0 or upwards
Display Unit
Beijer Electronics
X3 Marine 12 inches (Touch display)
OS3 / HHI
1.1 /1.0.2 or upwards
IOS_M
IO Unit Main
AVAT
IOC-4M (PLC)
Zerberus / AVAT
3.6.0 / 1.4.1 or upwards
IOS_N
IO Unit N
AVAT
IOC-4M (PLC)
Zerberus / AVAT
3.6.0 / 1.4.1 or upwards
ACP
IO Unit ACP
AVAT
IOC-4M (PLC)
Zerberus / AVAT
3.6.0 / 1.4.1 or upwards
Net Segmenter
Phoenix Contact
FL SWITCH 2208 (Industrial Managed Ethernet Switch)
FL_NAT_2000_V3
3.2.1 or upwards
Loosely Supply
Net Manager
Phoenix Contact
FL SWITCH 2208 (Industrial Managed Ethernet Switch)
FL_NAT_2000_V3
3.2.1 or upwards

ICM
(Injection Control Module)
Woodward
LECM
5418-8001
F52 or upwards
CMM
(Combustion Monitoring Module)
AVAT
E2PRECON-B10
HHP
317 or upwards

E2Service
AVAT
Service Software
E2Service / Windows
9.5.3 / 10 or upwards
# Versions are subject to change.

Testing

The testing of security capabilities for the HiMSEN engine control system has been carried out in a Simulation environment
developed by HD Hyundai Heavy Industries Co., Ltd., in compliance with RINA Rules and IACS UR E27.
There is no network communication to untrusted networks, and the test program includes the following security capabilities:


No.
Security capabilities
No.
Security capabilities
1
Human user identification and authentication
16
Timestamps
2
Account management
17
Communication integrity
3
Identifier management
18
Malicious code protection
4
Authenticator management
19
Security functionality verification
5
Wireless access management
(Not Applicable)
20
Deterministic output
6
Strength of password-based authentication
21
Information confidentiality
7
Authenticator feedback
22
Use of cryptography
8
Authorization enforcement
23
Audit log accessibility
9
Wireless use control
(Not Applicable)
24
Denial of service protection
10
Use control for portable and mobile devices
25
Resource management
11
Mobile code
26
System backup
12
Session lock
27
System recovery and reconstitution
13
Auditable events
28
Alternative power source
14
Audit storage capacity
29
Network and security configuration settings
15
Response to audit processing failures
30
Least Functionality

Reference Documents

- HiMECS-AE Asset Inventory Rev. 0, Doc. No. K2J025/HJK/1015 dated February 2026
- HiMECS-AE System Topology Diagram Rev.0. Doc. No. K2J025/HJK/1121 dated February 2026
- HiMECS-AE Security Capability Description Rev.1, Doc. No. K2J025/HJK/1020 dated April 2026
- HiMECS-AE Test Procedure Rev.1, Doc. No. K2J025/HJK/1201 dated April 2026
- HiMECS-AE Secure Development Lifecycle Description Rev.0, Doc. No. K2J025/HJK/1215 dated February 2026
- HiMECS-AE Security Configuration Guidance Rev.0, Doc. No. K2J025/HJK/1104 dated February 2026
- HiMECS-AE Maintenance & Verification plan Rev.0. Doc. No. K2J025/LNH/1031 dated February 2026
- HiMECS-AE Incident Response and Recovery Plan Rev.0, Doc. No. K2J026/CYM/0226 dated February 2026
- HiMECS-AE Change Management Procedure Rev. 0, Doc. No. K2J025/JCH/1215 dated December 2025
- HiMECS-AE Environmental Compliance Rev. 01, Doc. No. K2J0256/JCH/0421 dated May 2026

Test Report

- Cybersecurity Capability Demonstration Test Report Ref. No. K2J025/ZHJ/1201 Rev.1 witnessed by RINA Surveyor dated 24 April 2026
- The above documents and reports are archived in LD + with drawing no. PUEL-14932~14941: Letter ref. no. PUEL/2026/232/HK003 dated 17 April 2026

Note/Remark

- The product is always subject to compliance with RINA Rules and other Standards mentioned on certificate.
- The validity of this Certificate is subject to maintenance of the initial product conditions verified by RINA Services.
- Changes to the initial conditions must be communicated to RINA Services, which reserves the right to carry out further verification activity to confirm the validity of this Certificate.
- The rules, surveys and activities carried out by RINA, reports, certificates and other documents issued by RINA
are in no way intended to replace the duties and responsibilities of other parties such as Governments, designers,
ship builders, manufacturers, repairers, suppliers, contractors or sub-contractors, owners, operators, charterers,
underwriters, sellers or intended buyers of a ship or other product or system surveyed.
- For each installation on board, based on the ship’s configuration, the following documents are to be submitted to this Society in compliance with Chapter 5 of RINA Rules Pt C, Ch 3, Sec 5 “Cyber Resilience of On-board Systems and Equipment.



· CBS asset inventory
· Topology diagrams
· Cyber resilience test report

BUSAN 20 August 2026
**** NOTICE: This is NOT an official certificate ****