1. Product Description
+ Level / pressure measuring system for cargo, ballast , oil and water tanks comprising:
The PL 3700 can be manufactured with different programmable ranges for level and pressure application, absolute or gauge type. The transducer is fully welded and it is submersible (IP68), housed in stainless steel AISI 316L using a capacitive Ceramic diaphragm.
The PL3700X can be manufactured with different programmable ranges for level and pressure application, absolute or gauge type. The transmitter is fully welded and it is submersible (IP68), housed in stainless steel AISI 316L using a Ceramic diaphragm.
The PL3700XC model is especially dedicated for ballast and draft measurement. A special model exists for Atmospheric Pressure measurement. The transmitter is fully welded and it is submersible (IP68), housed in composite material, using a Ceramic diaphragm.
+ Technical specifications
| PL3700 | PL3700X/XC |
| Level measurements (mbar) | 0-120, 0-500, 0-2000, 0-4000 | 0-250, 0-400, 0-600, 0-1000, 0-2000, 0-5000, 0-25000 |
| Pressure measurements (mbar) | 900-1300, 800-2000, 0-7000, 0-20000, 2-25000 | 0-2000, 0-5000, 0-10000, 0-20000, 0-25000 |
| Power Supply | V=12/30 Vdc
(28Vdc max, if used in hazardous area). | V=12/30 Vdc
(28Vdc max, if used in hazardous area). |
| Output signal | 4 – 20 mA DC, (2 wires) | 4 – 20 mA DC, (2 wires) |
| Operating Temperature Ranges | Transducer :
-40°C to +125°C. (side mounting).
-40°C to +100°C. (immersed mounting with PTFE cable).
Amplifier : -25°C to +70°C. | Transmitter :
-20°C to +60°C. (side mounting)
-20°C to +60°C. (immersed mounting with PTFE cable)
Terminal : -20°C to +60°C |
| Temperature Drift | Between –20 and + 80°C : ± 0.80% FS
-Above +80°C : ± 0.025% FS per degree. | Zero+Full span 0.03% F.S. per degre (-40°C to 85°C)
Meter body Temperature:
±2°C nonlinearity (-20 to 80°C). |
Accuracy
(repeatability, hysteresis and non-linearity) | ± 0.30% F.S. at 20°C
up to ≤ ± 0.50% F.S (radiofrequency disturbance). | ± 0.25% F.S. at 25°C
(Note: +/-0.5% for 250mBar Cell) |
| Mechanical protection | Transducer: IP68 at 10bar
Remote box:
Sea water-resistant polyester housing: IP66.
Stainless steel housing: IP66/67 | Transmitter: IP68 at 10bar
Terminal box:
Sea water-resistant polyester housing: IP66/67.
Stainless steel housing: IP66/67 |
| Safety characteristics | Marking: II 1 G D Ex ia IIC or IIB T6 Ga
Ex ia IIIC T80°C Da
Tamb -20 °C to +70°C
Certificate: LCIE 02 ATEX 6180 X
IECEx LCI 11.0040X | Marking: II 1 G Ex ia IIB T4 Ga
Tamb -20 °C to +60°C
Certificate: LCIE 02 ATEX 6180 X
|
TYPE APPROVAL CERTIFICATE
No. ELE214025WS
Enclosure - Page 2 of 2
PL3700, PL3700X/XC
2. Reference Documents:
+ Application form: Filed by RINA with drawing No. SHEL-23930.
+ Manufacturer general information: Filed by RINA with drawing No. SHEL-23931.
+ Test Reports: Filed by RINA with drawing No. SHEL-23934 and SHEL-23935;
+ No change statement: Filed by RINA with drawing No. SHEL-23933.
+ Routine Test Reports: Signed by Surveyor and filed by RINA with drawing No. SHEL-23936.
+ Narrative report: Filed by RINA with drawing No. SHEL-23937.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-23932.
3. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
4. Renewal/Revision
+ March 26, 2020: initial certification. Certificate No. ELE239419WS.
+ May 7, 2025: renewed without design change. New certificate No. ELE214025WS revokes previous certificate. |
|