Double-leaf door installed in an A-60 steel bulkhead in accordance with the FTP Code 2010.
Bulkhead cut-out dimensions: max. 2366 mm × 2303 mm, max. clear opening dimensions: 2200 mm × 2200 mm, and door leaf dimensions: max. 1117 mm × 2213 mm; thickness 72 mm .
The subframe on three sides consists of a 60 mm × 60 mm × 5 mm L-shaped steel profile, fixed to the smooth side of the bulkhead by means of M8 steel bolts at 150 mm centres. The subframe is in turn bolted to the formed frame, measuring 28 mm × 91 mm × 42 mm × 3 mm, using M8 steel bolts at 150 mm centres. An intumescent strip of Forster 948000, measuring 24.5 mm × 1.5 mm, is installed between the frame and the subframe. The frame incorporates the door stop and the housing for the GMP837 silicone gasket.
Starting from the fire-exposed side, the door leaves are composed of a 1.5 mm steel sheet with folded edges, Extrabond No Fire adhesive, 300 g/m², a Promat Pluratech Marine Plus board, density 860 kg/m³, thickness 19 mm, a Rockwool SeaRox SL440 mineral wool board, density 150 kg/m³, thickness 40 mm, both certified as non combustible, and a 1.5 mm steel sheet with C-shaped profile. The assembly is enclosed by perimeter C-shaped steel profiles measuring 37 mm × 72 mm × 32 mm for the leaf fitted with the hatch. The leaf without the hatch is enclosed on the lock side by an H-shaped profile, riveted in two rows with spacing varying from 340 mm to 410 mm. On the outside of the C-profile, along the top edge, the lock side edge, and for 63 mm on the hinge side edge, a layer of Forster 948000 intumescent material, 24.5 mm × 1.5 mm, is applied.
The meeting stile between the two leaves is formed by a full-height profile attached to both leaves.
The leaves are fitted with concealed door closers.
One of the leaves is fitted with top and bottom flush bolts, maintained in the closed position.
Each leaf is fitted with two concealed hinges, positioned 125 mm from the top and bottom edges.
The left-hand leaf incorporates an hose port measuring 209 mm × 183 mm × 60 mm, consisting of two C-shaped steel profiles enclosing, starting from the fire-exposed side, a layer of Promat Promasil 1000P, density 300 kg/m³, thickness 54 mm, and a layer of Promat Promatect H, density 870 kg/m³, thickness 6 mm both certified as non combustible. The hose port is hinged to the door leaf.Field of application Fire resistant A-60 Class double leaf hinged door with fire hazard on the side opposite to the opening.
In case of doors in compliance to the "Agreement between the EEA EFTA States and the United States of America", the present certificate is valid at the following conditions:
- doors without windows;
- maximum door size tested;
- door used with a fire tested frame design.
Reference documents BLU BUD drawing No. A60DHB2Y Rev.0 dated 18/03/2026 enclosed on Test Report No. 2025CS015640/1 issued on 14 July 2026.Tests carried out Test as per RINA Test Laboratory report No. 2025CS015640/1 issued on 14 July 2026 according to Appendix 1 of IMO 2010 FTPC Part 3. |