1. Product Description
The MLI Ultra batteries are engineered for versatility, supporting a wide range of applications such as for example marine systems. Battery systems can vary in capacity and configuration. MLI Ultra batteries are designed for flexibility. The variations are permissible provided they comply with the manufacturer's specifications and applicable standards.
The main components of the system are as following:
- Battery Bank: up to 24 batteries, connected in series or parallel as specified in user manuals.
- Display Units: one or more monitors to display system status, measurements, and alarms
- Chargers: configured according to battery requirements and capable of communication with the batteries.
- Emergency Shutdown Devices: wired and powered independently from the battery system it controls.
- Fuses: sized according to applicable standards and capable specifications.
- System Loads: Any devices or circuits connected to the battery system.
Battery module:
| Model: | LF230 |
| Rated capacity [Ah] | 230 |
| Rated voltage [V] | 3,2 |
| Weight [kg] | 4.14 ± 0.124 |
| Cut-off charge voltage [V] | 3.85 |
| Cut-off discharge voltage [V] | 2.5 |
| Rated charge current [A] | 115 |
| Rated discharge current [A] | 115 |
| Max instant discharge current [A] | 230 |
| Operation temperature [°C] | -10 to +65 for charge and -30 to +60 for discharge |
Battery Pack
| Model: | MLI Ultra 24/6000 |
| Rated capacity [Ah] | 230 |
| Rated voltage [V] | 24 |
| Weight [kg] | 46.4 |
| Cut-off charge voltage [V] | 28.5 |
| Cut-off discharge voltage [V] | 22 |
| Rated charge current [A] | 80 |
| Rated discharge current [A] | 200 |
| Max instant charge current [A] | 230 |
| Max instant discharge current [A] | 230 |
| Operation temperature [°C] | 0 to +50 for charge and -20 to +50 for discharge |
TYPE APPROVAL CERTIFICATE
No. ELE018325XN
Enclosure - Page 2 of 2
Battery System
Battery Management System
The MLI Ultra is equipped with a BMS (Battery Management System), which:
- balances the voltages between the cells;
- protects each cel from undercharging and overcharging
- prevents too deep battery discharges
- monitors the temperature of battery cells
- communicates with Mastervolt charge devices over MasterBus or CZone
- sends out warning and alarms (to a compatible displaying device)
2. Reference Documents:
Documentation related to this certificate is listed under plan approval letter PLEL/2025/274/BKU01
3. Additional place of manufacture
516006 Zone 14,
Zhongkai Hi- tech Development Zone,
Huizhou, Guangdong
China
4. Notes/Remarks:
- The product is subject to the compliance with RINA Rules and Standards of 2025 mentioned on the certificates.
- When the aggregate capacity of a battery system exceeds the rating of 20 kWh, the battery system is to be type approved in accordance with relevant rules.
- Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
- The documentation mentioned in Pt C, Ch 2, App 2 of RINA Rules for the Classification of Ships is to be submitted for each particular application. Special attention is to be paid to the requested Risk Assessment.