1. Product Description
The H173F230-1P39S ESS Battery System is designed to be moduIe and can be scaled up to 1000VDC, The smallest entity of the battery is the battery module. The battery module can be connected in series to form a string. The maximum number of module connected in series is seven (7). The voltage of the string depends on the number of module connected in series. Strings are isolated from a common DC bus by a breaker. Strings connected in parallel form battery packs controlled by one or several BMS area units(BAU)depend on the arrangement.
1.1. LFP prismatic Cell
Cell Model | Rated Capacity | Limited Charge Voltage | Nominal Discharge Current | Nominal Discharge Current: | Peak Discharge Current | Discharge Cut-off Voltage |
L173F230 | 230Ah | 3,65V | 230A(1C) | 276A(1.2C) | 460A (2C) | 2.5V |
1.2. Cell Block
The cell block consists of 1P13S cell with Cell Voltage and temperature measure unit(FPC).
Block Model | Rated Capacity | Limited Charge Voltage | Nominal Discharge Current | Nominal Discharge Current: | Peak Discharge Current | Discharge Cut-off Voltage |
H173F230
-1P13S | 230Ah | 47.45V | 230A(1C) | 276A(1.2C) | 460A (2C) | 32.5V |
1.3. Module
The module Consists of three (3)1P13S cell blocks with a result in a 1P39S configuration.
Module Model | Rated Capacity | Limited Charge Voltage | Nominal Discharge Current | Nominal Discharge Current: | Peak Discharge Current | Discharge Cut-off Voltage |
H173F230A
-1P39S | 230Ah | 142.35V | 230A(1C) | 276A(1.2C) | 460A (2C) | 97.5V |
1.4. String
Nominal Voltage Module in Series Energy 1P39S (28.7kWh)
Nominal Voltage | 125V | 250V | 375V | 500V | 625V | 750V | 875V |
Module in Series | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
Energy | 28.7kWh | 57.4kWh | 86.1kWh | 114.8kWh | 143.5kWh | 172.2kWh | 200.9kWh |
TYPE APPROVAL CERTIFICATE
No. ELE664824WS
Enclosure - Page 2 of 3
ESS Battery System H173F230-1P39S
1.5. Battery Packs (Multi strings)
Strings (Engery: kWh) | 125V | 250V | 375V | 500V | 625V | 750V | 875V |
1 | 29 | 57 | 86 | 115 | 144 | 172 | 201 |
2 | 57 | 115 | 172 | 230 | 287 | 344 | 402 |
3 | 86 | 172 | 258 | 344 | 431 | 517 | 603 |
4 | 115 | 230 | 344 | 459 | 574 | 689 | 804 |
5 | 144 | 287 | 431 | 574 | 718 | 861 | 1005 |
6 | 172 | 344 | 517 | 689 | 861 | 1033 | 1205 |
7 | 201 | 402 | 603 | 804 | 1005 | 1502 | 1406 |
8 | 230 | 459 | 689 | 918 | 1148 | 1378 | 1607 |
9 | 258 | 517 | 775 | 1033 | 1292 | 1550 | 1808 |
10 | 287 | 574 | 861 | 1148 | 1435 | 1722 | 2009 |
1.6. Power Distribution unit(PDU)
Model:PDU-GT-1C-SH
PDU including master BMS unit, contactor, relay, fuse etc. electric elements which monitor and protect the battery system safely in operation.
1.7. Battery Slave Control Unit (BMU)
Model: ESBMM-6012-F
BMU is the Battery Slave Control Unite which is installed in each battery module and connected with the cell voltage and temperature measure unit (FPC) on cell block to monitoring the battery cell performance, and carry out the equalization strategy.
1.8. Battery Master Control Unit (BCU)
Model: ESBCM-F133
BCU is the Battery Master Control Unit which is installed in each PDU used for battery string contactor control, insulation monitoring system information collection, SOC/SOH calculation,
1.9. Battery Area Management unit(BAU)
Model: ESMU-1002564G
BAU is the Battery Area Management Unit which is installed room used for data analysis, monitoring and alarm management/storage, battery strings SOC and communicate with external applications (EMS, PCS, etc ) .
TYPE APPROVAL CERTIFICATE
No. ELE664824WS
Enclosure - Page 3 of 3
ESS Battery System H173F230-1P39S
2. Reference Documents:
Documentation:
+ Battery Cell technical specification. Filed by RINA with drawing No.SHEL-24491.
+ Battery Module technical specification. Filed by RINA with drawing No.SHEL-24492.
+ ESS Battery system technical specification. Filed by RINA with drawing No.SHEL-24493.
+ Battery chemistry safety analysis and design. Filed by RINA with drawing No.SHEL-24494.
+ Battery Management system function description. Filed by RINA with drawing No.SHEL-24495
+ Statement of conformity of IEC stantards. Filed by RINA with drawing No.SHEL-24503.
+ FAT reports and Narrative report witnessed by our attending Surveyor. Filed by RINA with drawing No.SHEL-24504.
+ Test program for the ESS battery system. Filed by RINA with drawing No.SHEL-24486.
+ ESS battery system date sheet. Filed by RINA with drawing No.SHEL-24488.
+ Battery system Risk Analysis. Filed by RINA with drawing No.SHEL-24489.
Test Reports:
+ BMS&IP EMC and Environment test reports carried by "Unilab (Shanghai) Testing Technology CO.,LTD" with report number UL153620241223001. Filed by RINA with drawing No.: SHEL-24497.
+ IEC-62620 Battery Cell test-report carried by "Shenzhen Precise Testing Technology CO.,LTD" with report number E-25010835A0. Filed by RINA with drawing No.: SHEL-24498.
+ IEC-62619 Battery Cell test-report carried by "Shenzhen Precise Testing Technology CO.,LTD" with report number E-NJ25010132A0. Filed by RINA with drawing No.: SHEL-24501.
+ IEC 62619-System test-report carried by "Shenzhen Precise Testing Technology CO.,LTD" with report number E-NJ25010039A0. Filed by RINA with drawing No.: SHEL-24499.
+ Propagation Test-report witnessed by Surveyor. Filed by RINA with drawing No.: SHEL-24500.
+ Thermal runaway test, Gas production analysis test and Explosion analysis test signed by attending Surveyor. Filed by RINA with drawing No.: SHEL-24504..
3. Notes/Remarks:
+ The products cited in this certificate also product in the company "China Lithium Battery Technology Co.,Ltd" with Manufacturer address "No.66, BinheNorth Road, High-techzone, Luoyang, Henan, China."
+ Battery rack is a welded steel frame to support and fix the battery modules and PDU, integrated cabling, cooling pipe and off-gas duct, so that to formed a complete battery pack. Standard single battery rack is eight (8) layers, and can be extend as necessary.
+ Power Connection Cabinet(PCC) is integrated the battery packs HV bus-bar connector, breaker, area BMS unit and with indicating lamp.
+ Cooling System (By option) mainly including chiller for refrigeration and Level-1,2,3 Pipeline for cooling water transport; Cooling system is used to control the temperature of cells under high-rate charging and discharging condition, which ensures the safety and longevity of cells;
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
+ The documentation mentioned in Pt C, Ch 2, App 2 of RINA Rules for the Classification of Ships is to be submitted for each particular application. Special attention is to be paid to the requested Risk Assessment. |
|