Product description
The 400 series are components for control, monitoring and safety systems of internal combustion engines.
| Type | Description | FW |
| DCU 408 | Engine control unit without user interface: 8x DI, 4x AI 4-20mA, 4x AI PT100, 1x pickup, Fixed functional inputs, Fixed- and configurable outputs, Dual J1939 interfaces, Ethernet &Modbus | 2.x |
| DCU 408E | Engine control unit without user interface: 8x DI, 4x AI 4-20mA, 4x AI PT100, 1x pickup, Fixed functional inputs, Fixed- and configurable outputs, Dual J1939 interfaces, Ethernet &Modbus | 3.x |
| DCU 410 | Engine control unit: 8x DI, 4x AI 4-20mA, 4x AI PT100, 1x pickup, Fixed functional inputs, Fixed- and configurable outputs, Dual J1939 interfaces, Ethernet & Modbus | 2.x |
| DCU410E | Engine control unit: 8x DI, 4x AI 4-20mA, 4x AI PT100, 1x pickup, Fixed functional inputs, Fixed- and configurable outputs, Dual J1939 interfaces, Ethernet & Modbus | 3.x |
| RIO 410 | Expansion I/O unit: 4x DI, 9x AI 4-20mA, 8x AI PT100, 2x AI K-type, 1x AI 0-5V, 2x DO, 2x CO | 1.x |
| RP 410 | Remote panel: up to 8 DCU’s, 4x DI, 4x CO, 2x RS232, 1x RJ45 Modbus/Ethernet/TCP, 8.4” touch screen, 1x USB Port, Configurable templates, IP56 (front) | 2.x |
| RP410E | Remote Panel: up to 8 DCU’s, 4x DI, 4x CO, 2x RS232, 1x RJ45 Modbus/Ethernet/TCP, 8.4” touch screen, 1x USB Port, Configurable templates, IP56 (front) | 3.x |
| RP 480i | Remote Panel: up to 8 DCU's, RJ45 Ehternet, 3x USB-A Port, 12.1" touch screen, IP56 (front) | 3.x |
| RPS | Redundant power selector. 2x 24V DC In, 1x 24V DC Out, 2x alarm PRI_OK & SEC_OK, IP4X. | - |
| SDU 404 | Safety unit: 4x DI, 1x pickup, wire break detection, LED indication, Overspeed test function, Power supply monitoring, Local acknowledge/ reset button | 1.x |
| SDU 410 | Safety unit: 8x DI, 2x pickup, wire break detection, LED indication, Overspeed test function, Power supply monitoring, Local acknowledge/ reset button | 1.x |
| SDU 420 | Safety Unit: 12x DI, 3 AI, 1x pickup, wire break detection, LED indication, Overspeed test function, Power supply monitoring, Local acknowledge/reset button | 1.x |
Documents:
Manual: - 1100269 dated June 10, 2015;
Quick installation guide: - 1000653 November 29, 2017; 1100274 November 30, 2017; 1100275 Rev. 4 dated April 2018;
- 1100406 November 30, 2017; 1100419 March 26, 2018; 1100426 March 26, 2018; 1100651 March 26, 2018; P/N 1500668 dated 20 January 2022, P/N 1500159 dated 21 January 2022
Test Reports:
DNV: - 2007-3495 Rev. 4 dated 18/06/2008
NEMKO: - 91130/8 Ver. 2 dated 4/4/2006, E21169.02 dated 2021-09-08, E21093.00 dated 2021-05-21,
SP Technical Research Institute of Sweden: - 4P01832E2 dated 23/04/2014; 4P01832E3 dated 25/04/2014;
- 4P02266-A dated 30/04/2014; 5P02252-E dated 2015-03-25; 5P06927 dated 2015-10-16;
RISE: 9P06118 rev B dated 2019-12-09, 9P04380 dated 2019-10-22, P113225 dated 2022-01-18, P111935 rev B dated 2021-11-25, 2P03725 dated 2020-11-25
Remarks:
- The products fulfill EC-Code: 3a3.
- The equipment fulfill the EMC requirements for installation in power distribution zone.
- System configuration is to be such that: + Engine Safety System is to be independent from other systems; relevant sensors
are to be additional to the ones used for monitoring and control purposes.
+ The engine is to be controlled locally, when a failure on the engine remote control system is occurring.
+ Local monitoring of essential parameters necessary for a safe local control of the engine is to be provided (even in case
of remote monitoring system failure).
- In case of major software modification detailed information and suitable documents are to be submitted to the Society.
- Drawings of each system configuration is to be sent for approval before installation on board.
- This certificate annuls and replaces the previous one N° ELE337018XG. |
|