ELE175526XGENG- -  -  N- Proline Promass F, O, X, 300 / 500 -N- S- S- -07/09/2026- Prodotti Elettrici- - SN- N- Giuseppe Russo- N-  - 189,243Giuseppe RussoBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE175526XG- N-Sep 6, 2031189243
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE175526XG - (ENG)
Certificate date 07/09/2026
Type Impianti di Automazione
Product Flow Meters

Model or Denomin.
Items
Proline Promass  F, O, X, 300 / 500
Applicant ENDRESS+HAUSER FLOWTEC AG
Place of requester KAGENSTRASSE, 4  %  4153 Reinach  % SWITZERLAND
Tel. N.,Fax, Email 0041617156111, ---, ---
Standards Rules for the Classification of Ships - Part C - Machinery Systems and Fire Protection,Ch. 3, Sec. 8, Table 1
Expire date 06/09/2031
Head Office Hamburg
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE175526XG
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Flow Meters
Type Proline Promass  F, O, X, 300 / 500
Applicant ENDRESS+HAUSER FLOWTEC AG
KAGENSTRASSE, 4
4153 Reinach
SWITZERLAND
Reference standards Rules for the Classification of Ships - Part C - Machinery Systems and Fire Protection,Ch. 3, Sec. 8, Table 1
  

 
 
   .   This Certificate is valid until September 6, 2031
_________________________________
RINA Services S.p.A.
Giuseppe Russo
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE175526XG
Enclosure - Page 1 of 4
Proline Promass  F, O, X, 300 / 500
Measuring principle
The measuring principle is based on the controlled generation of Coriolis forces. These forces are always present in a system when both translational and rotational movement are superimposed. The amplitude of the Coriolis forces depends on the moving mass Δm, its velocity v in the system and thus on the mass flow. Instead of a constant rotational velocity ω, the sensor use oscillation.
In the sensors two parallel measuring tubes containing flowing fluid oscillate antiphase, acting like a tuning fork.
The Coriolis forces produced at the measuring tubes cause a phase shift in the tube oscillations.
- At zero flow (fluid is standstill) the tubes oscillate in phase.
- Mass flow causes deceleration of the oscillation at the inlet of the tubes and acceleration at the outlet.
The phase difference increases with increasing mass flow. Electrodynamic sensors register the tube oscillations at the inlet and outlet. System balance is ensured by antiphase oscillation of the two measuring tubes. The measuring principle operates independently of temperature, pressure, viscosity, conductivity and flow profile.

Direct measured variable: Mass Flow, Density, Temperature

Calculated measured variables: Volume flow, Corrected volume flow, Reference density

Measuring system consists of a transmitter Proline Promass 300 / 500 and a sensor type F or O or X

Power supply: 24 Vdc, 100-230 Vac, 100-230 Vac / 24 Vdc


Output: 4 to 20mA HART; Pulse/Frequency /Switch, Modbus RS485; Ethernet/IP; Profibus PA/ DP; Profinet; Foundation Fieldbus Measuring accuracy / medium temperature and pressure / materials, mounting: refer to the E+H “Technical Information”
Communication and protocols; refer to the
E+H “Operating Instructions”
Operation: With or without display; Housing: Aluminum or Stainless Steel; Degree of Protection: IP66, IP 67

Firmware versions → Interface / Protocol
01.06.zz →_HART; 01.01.zz → Profibus PA;01.00.zz → Profibus DP; 01.06.zz → Modbus;
01.00.zz → Ethernet /IP; 01.01.zz →Profinet; 01.00.zz → Foundation Fieldbus

PROMASS F type sensor - Measuring range for liquids
DN [mm]
DN [in]
Measuring range full scale values
[kg/h]
[lb/min]
8
3/8
0 to 2000
0 to 73.50
15
1/2
0 to 6500
0 to 238.9
25
1
0 to 18000
0 to 661.5
40
1 1/2
0 to 45000
0 to 1654
50
2
0 to 70000
0 to 2573
80
3
0 to 180000
0 to 6615
100
4
0 to 350000
0 to 12860
150
6
0 to 800000
0 to 29400
250
10
0 to 2200000
0 to 80850

PROMAS F type sensor - Measuring range for gases

DN [mm]
DN [in]
[kg/m3]
8
3/8
60
15
1/2
80
25
1
90
40
1 1/2
90
50
2
90
80
3
110
100
4
130
150
6
200
250
10
200


TYPE APPROVAL CERTIFICATE
No. ELE175526XG
Enclosure - Page 2 of 4
Proline Promass F, O, X, 300 / 500

Promass O type sensor - Measuring range for liquids
DN [mm]
DN [in]
Measuring range full scale values
[kg/h]
[lb/min]
80
3
0 to 180 000
0 to 6615
100
4
0 to 350 000
0 to 12860
150
6
0 to 800 000
0 to 29400
250
10
0 to 2200 000
0 to 80850

Promass O type sensor - Measuring range for gases
DN [mm]
DN [in]
[kg/m3]
80
3
110
100
4
130
150
6
200
250
10
200

Promass X type sensor - Measuring range for liquids
DN [mm]
DN [in]
Measuring range full scale values
[kg/h]
[lb/min]
300
12
0 to 4100 000
0 to 4520
350
14
0 to 4100 000
0 to 4520
400
16
0 to 4100 000
0 to 4520

Promass X type sensor - Measuring range for gases
DN [mm]
DN [in]
[kg/m3]
300
12
200
350
14
200
400
16
200

Variants according to order code:
PROLINE PROMASS F300
Order Code 8F3B aa – bb c dd e f g h i jj kkk l
aa
Nominal Diameter
08; 15; 25; 40; 50; 80; 1H; 1F; 2F
bb
Approval; Transmitter + Sensor
Any two letter and/or number combination
c
Power Supply
D; E; I
dd
Output; Input 1
BA; BB; CA; CB; GA; HA; LA; MA; NA; RA; SA; TA
e
Output; input 2
A; B; C; D; E; F; G; H; I; J
f
Output; input 3
A; B; C; D; E; F; G; H; I; J
g
Display Operation
A; F; G; M; O
h
Housing
A; B; L
i
Electrical connection
A; B; C; D; L; M; N; P; R; S; T; U; V; 3; 4; 5
jj
Meas. Tube Mat., Wetted Parts Surface
HA; LA; SA; SB; SC; SD, SE; SF; TH
kkk
Process Connection
Any triple letter and/or number combination
l
Calibration Flow
A; B; C; D; K; L; M; 8; 9

Variants according to order code:
PROLINE PROMASS F500
Order Code 8F5B aa – bb c dd e f g h i j k l m nn ooo p
aa
Nominal Diameter
08; 15; 25; 40; 50; 80; 1H; 1F; 2F
bb
Approval; Transmitter + Sensor
Any two letter and/or number combination
c
Power Supply
D; E; I; X
dd
Output; Input 1
BA; BB; CA; CB; GA; HA; LA; MA; NA; RA; SA; TA; XX
e
Output; Input 2
A; B; C; D; E; F; G; H; I; J; X
f
Output; Input 3
A; B; C; D; E; F; G; H; I; J; X
g
Output; Input 4
A; B; C; D; E; G; H; I; J; X
h
Display; Operation
F; G; X
i
Integrated ISEM Electronic
A; B
j
Transmitter Housing
A; L; X
k
Sensor junction Housing
A; B; C; L
l
Cable Sensor Connection
A; B; E; F; 1; 2; 3
m
Electrical connection
A; B; C; D; L; M; N; P; R; S; T; U; V; 3; 4; 5
nn
Meas. Tube Mat., Wetted Parts Surface
HA; LA; SA; SB; SC; SD; SE; SF; TH
ooo
Process Connection
Any triple letter and/or number combination
p
Calibration Flow
A; B; C; D; K; L; M; 8; 9
TYPE APPROVAL CERTIFICATE
No. ELE175526XG
Enclosure - Page 3 of 4
Proline Promass F, O, X, 300 / 500
Variants according to order code:
PROLINE PROMASS O300
Order Code 8O3B aa – bb c dd e f g h i jj kkk l
aa
Nominal Diameter
80; 1H; 1F; 2F
bb
Approval; Transmitter + Sensor
Any two letter and/or number combination
c
Power Supply
D; E; I
dd
Output; Input 1
BA; BB; CA; CB; GA; HA; LA; MA; NA; RA; SA; TA;
e
Output; Input 2
A; B; C; D; E; F; G; H; I; J
f
Output; Input 3
A; B; C; D; E; F; G; H; I; J
g
Display; Operation
A; F; G; M; O
h
Housing
A; L
i
Electrical connection
A; B; C; D; L; M; N; P; R; S; T; U; V; 3; 4; 5
jj
Meas. Tube Mat. , Wetted Parts Surface
FA
kkk
Process Connection
Any triple letter and/or number combination
l
Calibration Flow
A; B; C; D; K; L; M; 8; 9

Variants according to order code:
PROLINE PROMASS O500
Order Code 8O5B aa – bb c dd e f g h i k l m nn ooo p
aa
Nominal Diameter
80; 1H; 1F; 2F
bb
Approval; Transmitter + Sensor
Any two letter and/or number combination
c
Power Supply
D; E; I; X
dd
Output; Input 1
BA; BB; CA; CB; GA; HA; LA; MA; NA; RA; SA; TA; XX
e
Output; Input 2
A; B; C; D; E; F; G; H; I; J; X
f
Output; Input 3
A; B; C; D; E; F; G; H; I; J; X
g
Output; Input 4
A; B; C; D; E; G; H; I; J; X
h
Display; Operation
F; G; X
i
Integrated ISEM Electronic
A; B
j
Transmitter Housing
A; L; X
k
Sensor junction Housing
A; B; C; L
l
Cable Sensor Connection
A; B; E; F; 1; 2; 3
m
Electrical connection
A; B; C; D; L; M; N; P; R; S; T; U; V; 3; 4; 5
nn
Meas. Tube Mat., Wetted Parts Surface
FA
ooo
Process Connection
Any triple letter and/or number combination
p
Calibration Flow
A; B; C; D; K; L; M; 8; 9

Variants according to order code:
PROLINE PROMASS X300
Order Code 8X3B aa – bb c dd e f g h i jj kkk l
aa
Nominal Diameter
3R; 3F; 3E
bb
Approval; Transmitter + Sensor
Any two letter and/or number combination
c
Power Supply
D; E; I
dd
Output; Input 1
BA; BB; CA; CB; GA; HA; LA; MA; NA; RA; SA; TA;
e
Output; Input 2
A; B; C; D; E; F; G; H; I; J
ff
Output; Input 3
A; B; C; D; E; F; G; H; I; J
g
Display; Operation
A; F; G; M; O
h
Housing
A; L
i
Electrical connection
A; B; C; D; L; M; N; P; R; S; T; U; V; 3; 4; 5
jj
Meas. Tube Mat., Wetted Parts Surface
SA
kkk
Process Connection
Any triple letter and/or number combination
l
Calibration Flow
A; B; C; D; 8; 9









TYPE APPROVAL CERTIFICATE
No. ELE175526XG
Enclosure - Page 4 of 4
Proline Promass F, O, X, 300 / 500

Variants according to order code:
PROLINE PROMASS X500
Order code 8X5B aa - bb c dd e f g h i j k l m nn ooo p
aa
Nominal Diameter
3R; 3F; 3E
bb
Approval; Transmitter + Sensor
Any two letter and/or number combination
c
Power Supply
D; E; I; X
dd
Output; Input 1
BA; BB; CA; CB; GA; HA; LA; MA; NA; RA; SA; TA; XX
e
Output; Input 2
A; B; C; D; E; F; G; H; I; J; X
f
Output; Input 3
A; B; C; D; E; F; G; H; I; J; X
g
Output; Input 4
A; B; C; D; E; G; H; I; J; X
h
Display; Operation
F; G; X
i
Integrated ISEM Electronic
A; B
j
Trasmitter Housing
A; L; X
k
Sensor Junction Housing
L
l
Cable, Sensor Connection
A; B; E; F; 1; 2; 3
m
Electrical Connection
A; B; C; D; L; M; N; P; R; S; T; U; V; 3; 4; 5
nn
Meas. Tube Mat., Wetted Parts Surface
SA
ooo
Process Connection
Any triple letter and/or number combination
p
Calibration Flow
A; B; C; D; 8; 9

Proline Promass technical information:
TI01221D/06/EN/09.21 F300
TI01222D/06/EN/08.21 F500
TI01275D/06/EN/07.21 O300
TI01285D/06/EN/07.21 O500
TI01279D/06/EN/06.19 X300
TI01289D/06/EN/06.19 X500

Proline Promass operating instruction:
BA01850DEN_0118 F300 PROFIBUS-DP
BA01860DEN_0118 O300 PROFIBUS-DP
BA01864DEN_0118 X300 PROFIBUS-DP
BA01873DEN_0118 F500 PROFIBUS-DP
BA01876DEN_0118 O500 PROFIBUS-DP
BA01880DEN_0118 X500 PROFIBUS-DP
BA01507DEN_0218 F300 PROFIBUS-PA
BA01510DEN_0218 O300 PROFIBUS-PA
BA01514DEN_0218 X300 PROFIBUS-PA
BA01551DEN_0218 F500 PROFIBUS-PA
BA01554DEN_0218 O500 PROFIBUS-PA
BA01558DEN_0218 X500 PROFIBUS-PA
BA01728DEN_0117 F300 EtherNet/IP
BA01731DEN_0117 O300 EtherNet/IP
BA01735DEN_0117 X300 EtherNet/IP
BA01750DEN_0117 F500 EtherNet/IP
BA01753DEN_0117 O500 EtherNet/IP
BA01757DEN_0117 X500 EtherNet/IP
BA01739DEN_0421 F300 PROFINET
BA01742DEN_0421 O300 PROFINET
BA01746DEN_0319 X300 PROFINET
BA01761DEN_0421 F500 PROFINET
BA01764DEN_0421 O500 PROFINET
BA01768DEN_0319 X500 PROFINET
BA01518DEN_0116 F300 Foundation Fieldbus
BA01521DEN_0116 O300 Foundation Fieldbus
BA01525DEN_0116 X300 Foundation Fieldbus
BA01562DEN_0116 F500 Foundation Fieldbus
BA01565DEN_0116 O500 Foundation Fieldbus
BA01569DEN_0116 X500 Foundation Fieldbus
BA01496DEN_0521 F300 Modbus RS485
BA01499DEN_0521 O300 Modbus RS485
BA01503DEN_0419 X300 Modbus 485
BA01540DEN_0521 F500 Modbus RS485
BA01543DEN_0521 O500 Modbus RS485
BA01547DEN_0419 X500 Modbus 485
BA01485DEN_0421 F300 HART
BA01488DEN_0421 O300 HART
BA01492DEN_0319 X300 HART
BA01529DEN_0421 F500 HART
BA01532DEN_0421 O500 HART
BA01536DEN_0319 X500 HART
Test Reports, Technical Specification and supporting documents are archived in RINA FILE 2021CS01353

General remark:


For installation in Hazardous Area, the suitable Ex ATEX Certification to be made available.

Approval limitation


This Type Approval Certificate does not cover wetted parts;
Specific application shall be separately examined according to the applicable requirements, depending on temperature, pressure and used medium.

Additional place of manufacturing

Endress + Hauser Flowtec (China) Co. Ltd


Suzhou
China

Hamburg September 7, 2026
**** NOTICE: This is NOT an official certificate ****