Product Description
- The HMI iXP3 Series is LCD Touch Panels used for Human Machine Interface
Main features
- TFT-LCD Panel size: iXP3-0800D-MR - 8.4", iXP3-1000D-MR - 10.4", iXP3-1200D-MR - 12.1", iXP3-1500D-MR - 15"
- Max. Resolution: 800 x 600 pixel, 1024 x 768 pixcel
- Color Indication : 24 bit
- Interface : RS232C, RS-422/485, Ethernet, USB and SD Card
- Backlight : LED Type
- Power supply: DC 24V
- Processor : 1.6 GHz, Quad core
- Touch Panel Type : Capacitive Touch
- Ingress Protection : IP66(front)
Reference Documents
- Technical Document: LS ELECTRIC's Specification DOC No: 2024-KD007-630-0003 Version 1.2 (Revision Date: 2024.10.29) and Technical data Ref. No. DOC No: 2024-KD007-630-005.01 Version 1.0 (Revision Date: 2024.02.07), DOC No: 2024-KD007-630-005.02 Version 1.0 (Revision Date: 2024.02.07), DOC No: 2024-KD007-630-005.03 Version 1.0 (Revision Date: 2024.02.07), DOC No: 2024-KD007-630-005.04 Version 1.0 (Revision Date: 2024.02.07)
- User Manual : LS ELECTRIC's manual : XGT Panel HW Manual_iXP3_eng_V1.1 (2024.10)
- Test report: DT&C's Environment Test Report Ref. No. DRCREL2409-0668 dated 05/09/2024, No. DRCREL2409-0669 dated 05/09/2024, No. DRCREL2409-0670 dated 05/09/2024, No. DRCREL2410-0742 dated 05/09/2024, No. DREETC2410-0101 dated 16/10/2024, DREETC2410-0100 dated 16/10/2024
- Visual Inspection & Performance Test: LS ELECTRIC's Human Machine Interface Performance Test Report DOC No: DOC No: 2024-KD007-630-008 attended by RINA Surveyor.
- Asbestos-Free Declaration: LS ELECTRIC's official letter dated 27/03/2024, Zero Tech Win's official letter dated 28/03/2024
- The above documents and reports are archived in LD+ as "PUEL-11800~11803".
Note/Remark
- The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
- Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
- RINA annul audit to the Manufacture’s production site is required in case of products for which testing of each unit or batch is not required to be attended by the surveyor.
- Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.
- Software Type Approval is not included in the scope of this certificate.
- Location : general power distribution zone except bridge and deck zone
|
|