B-15 Class bulkhead having maximum dimensions of 2000 (W) mm x 2160 (H) mm and thickness of 37 mm composed of panels having maximum dimensions of 600 mm (W) x 1960 mm (H) certified by RINA with EC Type Examination Certificate No. MED094723CS/011 dated 15 December 2023. The bulkhead may be fitted with the following accessories:
- carbon steel sheet box, 1 mm thick, having dimensions of 300 x 300 mm and height of 100 mm insulated, on the internal side, with two layers of mineral wool with glass fabric type Paroc Fire Slab 220 + N5, 15 mm thick each and having density of 220 kg/m3. The box is fixed, by means of screws (4.8x22 mm and pitch 150 mm), to a steel sheet, 1 mm thick, screwed to the bulkhead joints. The bulkhead insulation is provided, on the box center, of one hole having diameter of 120 mm.
- carbon steel sheet box, 1 mm thick, having dimensions of 305 x 630 mm and height of 110 mm insulated, on the internal side, with two layers of mineral wool with glass fabric type Paroc Fire Slab 220+N5, 15 mm thick each and having density of 220 kg/m3 fixed to steel sheet with pins. On the box perimeter, on the side exposed to fire, four steel square pipes having dimensions of 20x10x1 mm (two horizontal and two vertical) are tack welded together; the vertical pipes are screwed to the C shaped steel profile, 2 mm thick, fitted on the lower part of the bulkhead. The box is fitted, on the internal, with steel āLā shaped steel profiles, 1 mm thick and having dimensions of 40x20 mm, screwed to the square pipes. The box is fixed, by means of screws (4.8x22 mm and pitch 200 mm), to a steel sheet, 1 mm thick, screwed to the bulkhead joints. On the upper side of the box, a further steel sheet, 1 mm thick, is screwed.Field of application Fire resisting B-15 Class bulkhead with accessories; the fire hazard is on the side fitted with the omega shaped steel profiles. The bulkhead is to be installed with the untested side adjacent to the untested side of another B Class bulkhead ensuring that the level of protection indicated in the relevant fire integrity tables included in SOLAS Chapter II-2/Reg. 9.2 Thermal and Structural Boundaries is always fulfilled. Reference documents Santarossa SpA drawing No. 24PC00170 Rev. 1 dated 13 February 2009 approved on 16 February 2009 with endorsement No. LABS-215.Tests carried out Tests as per RINA Test Laboratory report No. 2009CS01668 issued on 16 February 2009 according to Resolution IMO A.754(18). |