Tank Monitoring and Level Alarm System consisting of:
Display Unit - TDU R.2
Control Unit - TCU R.2
Analogue Input Unit - AN-ZBANA R5/6/7
Analogue/Digital Input Unit - AN-ZBHART R1
Digital Input Unit - AN_ZB485 Rev.5
Panel Indicator - TPC140 R1
Deck display - TPC196 R1
Junction box - AJB 500-x
Amplifier - AN-SGCNV (incl. in AJB 500-x)
Radar - SC R5 Rev.1
FMCW radar - SC R8
Pressure/ Temperature sensor - P906-011x
Pressure transmitters - ATM.1ST/N/X, SPT900-series (4-20mA)
Software: - Application software/firmware versions: 2.14.Y.Z
When the type approved software is revised (affecting all future deliveries) RINA is to be informed by
forwarding updated software version documentation.
Application: - Level monitoring
- High / High-high cargo level alarm system
- Cargo pressure monitoring
- Water ingress detection
Specifications / documents:
- Instruction manual AN-SGCNV, AN-SGCNV-EXT, AN-ZB485
- Product Type AN-ZBHART
- Installation operation & Maintenance Instruction Manual SPT 900 Series
- Instruction Manual SC R5 - Tank Level Radar
- Instruction manual SCANRAD SCR8
- System overview - Type approval certificate - dgg. No. : TN150005-DNV_G
TYPE APPROVAL CERTIFICATE
No. ELE063622XP
Enclosure - Page 2 of 2
Tank Monitoring and Level Alarm System
Test Reports:
- TTS Test report No. WZH031304016KA, dated 208-08-2000
- EMS test of Radar GDRD 57, 4P06268-E1,E2, E3 dated 2014-10-23, 2014-11-24
- Environmental test of tank radar SC-PR01, 5P07751, dated 2016-02-04
- EMC tests of Radar GDRD 57, 6P03508-E1, dated 2016-07-07
- Measurement Report EMC Test Report, No.: 2004WSU029-E1, dated 27-10-2020
- DNV Technical Report No.: 2003-3467
- DNV Technical Report No.: 2004-3278
- DNV Technical Report No.: 2006-3339
- Nemko test report - EMC , 23802
- Eurofins EMC Test Certificate
- Eurofins EMC Test Report 3410 CR, dated 22-10-2021,
- Korea Marine Equipment Research Institute - EMC Test report dated 2018-04-18
Applications/ Limiatations:
- Ex installations to be approved in each case according to the Rules and Ex-Certification/ Special
Condition for Safe Use listed in valid Ex-certificate issued by a notified/recognized Certification Body.
Ex-certification is not covered by this certificate.
- For each application the following documentation is to be submitted for approval: functional description, system block diagram including power supply arrangement, list of control and monitored points