ELE063622XPENG- -  -  N- Tank Monitoring and Level Alarm System -N- S- S- -16/12/2022- Prodotti Elettrici- - SN- N- Jaroslaw Kondracki- N-  - 1,044,849Jaroslaw KondrackiBProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE063622XP- N-Dec 15, 20271044849
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE063622XP - (ENG)
Certificate date 16/12/2022
Type Impianti di Automazione
Product Sistema di monitoraggio del carico

Model or Denomin.
Items
Tank Monitoring and Level Alarm System
LEVEL MONITORING SYSTEM, CARGO PRESSURE AND TEMPERATURE MONITORING SYSTEM
Applicant Scanjet Ariston AS
Place of requester Moen 12  %  3948 Porsgrunn  % NORWAY
Tel. N.,Fax, Email ---, ---, ---
Standards RINA Rules for the Classification of Ships. Part C – Machinery, Systems and Fire protection. Ch. 3, Section 6, Table 1.,IACS Unified requirements E10 Rev.8
Expire date 15/12/2027
Head Office GDANSK
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE063622XP
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Cargo monitoring system
Type Tank Monitoring and Level Alarm System
LEVEL MONITORING SYSTEM,CARGO PRESSURE AND TEMPERATURE MONITORING SYSTEM
Applicant Scanjet Ariston AS
Moen 12
3948 Porsgrunn
NORWAY
Reference standards RINA Rules for the Classification of Ships. Part C – Machinery, Systems and Fire protection. Ch. 3, Section 6, Table 1.,IACS Unified requirements E10 Rev.8
  

 
 
   .   This Certificate is valid until December 15, 2027
_________________________________
RINA Services S.p.A.
Jaroslaw Kondracki
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE063622XP
Enclosure - Page 1 of 2
Tank Monitoring and Level Alarm System

Tank Monitoring and Level Alarm System consisting of:

Display Unit - TDU R.2
Control Unit - TCU R.2
Analogue Input Unit - AN-ZBANA R5/6/7
Analogue/Digital Input Unit - AN-ZBHART R1
Digital Input Unit - AN_ZB485 Rev.5
Panel Indicator - TPC140 R1
Deck display - TPC196 R1
Junction box - AJB 500-x
Amplifier - AN-SGCNV (incl. in AJB 500-x)
Radar - SC R5 Rev.1
FMCW radar - SC R8
Pressure/ Temperature sensor - P906-011x
Pressure transmitters - ATM.1ST/N/X, SPT900-series (4-20mA)


Software: - Application software/firmware versions: 2.14.Y.Z
When the type approved software is revised (affecting all future deliveries) RINA is to be informed by
forwarding updated software version documentation.


Application: - Level monitoring
- High / High-high cargo level alarm system
- Cargo pressure monitoring
- Water ingress detection




Specifications / documents:
  • Instruction manual AN-SGCNV, AN-SGCNV-EXT, AN-ZB485
  • Product Type AN-ZBHART
  • Installation operation & Maintenance Instruction Manual SPT 900 Series
  • Instruction Manual SC R5 - Tank Level Radar
  • Instruction manual SCANRAD SCR8
  • System overview - Type approval certificate - dgg. No. : TN150005-DNV_G













TYPE APPROVAL CERTIFICATE
No. ELE063622XP
Enclosure - Page 2 of 2
Tank Monitoring and Level Alarm System
Test Reports:
  • TTS Test report No. WZH031304016KA, dated 208-08-2000
  • EMS test of Radar GDRD 57, 4P06268-E1,E2, E3 dated 2014-10-23, 2014-11-24
  • Environmental test of tank radar SC-PR01, 5P07751, dated 2016-02-04
  • EMC tests of Radar GDRD 57, 6P03508-E1, dated 2016-07-07
  • Measurement Report EMC Test Report, No.: 2004WSU029-E1, dated 27-10-2020
  • DNV Technical Report No.: 2003-3467
  • DNV Technical Report No.: 2004-3278
  • DNV Technical Report No.: 2006-3339
  • Nemko test report - EMC , 23802
  • Eurofins EMC Test Certificate
  • Eurofins EMC Test Report 3410 CR, dated 22-10-2021,
  • Korea Marine Equipment Research Institute - EMC Test report dated 2018-04-18





Applications/ Limiatations:
  • Ex installations to be approved in each case according to the Rules and Ex-Certification/ Special
Condition for Safe Use listed in valid Ex-certificate issued by a notified/recognized Certification Body.
Ex-certification is not covered by this certificate.
  • For each application the following documentation is to be submitted for approval: functional description, system block diagram including power supply arrangement, list of control and monitored points

GDANSK December 16, 2022
**** NOTICE: This is NOT an official certificate ****