MED321026CS!002ENG- -  -  N- HSR_A60 -N- S- S- -11/06/2026- Marine Equipment- - SN- S- - N-  - 883,804B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED321026CS/002- N-Jun 10, 2031883804
 
Form
  Marine Equipment(TO)
Certification N. MED321026CS/002 - (ENG)
Certificate date 11/06/2026
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
HSR_A60
Applicant CARETTA INTERIORS AE
Place of requester THESI MAURI ORA, INDUSTRIAL AREA OF ASPROPYRGOS  %  19300 ATHENS  % GREECE
Tel. N.,Fax, Email +30 210 6621506, +30 210 6621507, caretta.interiors@gmail.com
Directive (EU) 2025/1533
Standards IMO Res. MSC.307(88)-(2010 FTP Code) - IMO MSC.1/Circ. 1319
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Request 21/05/2026
Expire date 10/06/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED321026CS/002

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type HSR_A60
Applicant CARETTA INTERIORS AE
THESI MAURI ORA, INDUSTRIAL AREA OF ASPROPYRGOS,19300 ATHENS,GREECE
Testing standards IMO Res. MSC.307(88)-(2010 FTP Code) - IMO MSC.1/Circ. 1319
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Issued in Genoa on
This Certificate is valid until
June 11, 2026
June 10, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED321026CS/002
Page 1 of 2

Product description

Single leaf hinged door whose maximum clear opening dimensions are 1205 mm (W) and 2250 mm (H). The door leaf, having maximum dimensions of 1237 mm in width and 2260 mm in height, is made of a sandwich panel named NEPTUNE BOARD composed of two outer moulded surfaces made of magnesia, magnesium chloride and water glass and an internal panel of mineral wool. The outer skins have thickness of 2 mm each and density of 1250 kg/m3; the mineral wool (certified non-combustible in conformity to the requirements of the IMO FTP Code) has thickness of 46 mm and density of 160 kg/m3. Between the two skins, every 100 mm, vertical stiffeners made of the same material as the two skins are fitted. The composite panel is contained within two steel sheets having thickness of 1.25 mm. The leaf may be fitted with a window having maximum clear light of 685 mm in width and 685 mm in height. The glass, type PYROBEL 25, has nominal thickness of 26.6 mm. The glass retaining frame, made of steel profiles having thickness of 3 mm and 1.25 mm, is fixed to the leaf by means of screws type M5x20 every 185 mm. Between the frame and the glass retaining frame ceramic tapes type KERAFIX FLEXLIT 25x5 mm are fitted, whereas between the glass and the leaf intumescent strips type PALUSOL KERAFIX 30x3.8 are fitted. The glass retaining frame is also provided with a layer of Neptune Board having thickness of 14 mm. The door frame, composed of steel profiles having thickness of 4 mm, is fixed to the bulkhead by means of bolts type M8x25 every 200 mm. The door may be equipped with a self-closing hose port.
Field of application
Fire resistant A-60 Class single leaf hinged door with the fire hazard on both sides in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf;
- maximum door size tested;
- door used with a fire tested frame design.
The surfaces of this division may be fitted with products having low flame spread characteristics, installed as described in the relevant type approval certificates and satisfying the requirements of SOLAS 74 Reg. II-2 as applicable.
Reference documents
PANMERC ENTERPRISES LTD drawing No. HSR-A60-120 Rev. A dated 18 January 2016 approved on 16 February 2016 with endorsement No. LABS-1215.
Tests carried out
Test as per RINA Test Laboratory report No. 2015CS013569/5 issued on 23 March 2016 according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED321026CS/002
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****