Product Description
The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial refrigeration and general industrial application in explosive zones acc. To 2014/34/EU ATEX directive, explosive zone 1, for surface equipment, category 2.
It includes usage in refrigeration systems with ammonia, hydrocarbons and other applications where presence of flammable gases, vapours and mists are likely to occur.
RT-E pressure switches and thermostats for use in explosive zones incorporate SPDT changeover switch where contact position depends on pressure or temperature value of the system.
Main characteristics of Pressure Switch and Thermostat Type KP and KPI (Single)
Enclosure: IP54 / IP66
Ambient temperature: -20°C - 65°C
Cable entry: 2 x Pg 13.5 Cable diameter: 6 – 14 mm
Contact material: Gold plated AgCdO
Contact load: Must be used with a certified Ex ia barrier satisfying the input parameters
Contact system: Single-pole changeovers switch (SPDT)
Pressure Switches for R717, HCFC, HFC and HC refrigerants:
Type | Regulating Range | Differential Dp | Max. Working Pressure PS | Reset |
RT 112E | 0.1 - 1.1bar | 0.07 – 0.16bar | 7bar | Auto |
RT 113E | 0.0 – 0.3bar | 0.01 – 0.05bar | 0.4bar | Auto |
RT 121E | -1.0 - 0.0bar | 0.09 - 0.40bar | 7bar | Auto |
RT 1AE | -0.8 – 5.0bar | 0.5 – 1.6bar | 22bar | Auto |
RT 116E | 1 – 10bar | 0.3 – 1.3bar | 22bar | Auto |
RT 5E | 4 – 17bar | 1.2 – 4bar | 22bar | Auto |
RT 6AEW | 5 – 25bar | 3bar | 34bar | Auto |
RT 6AEB | 10 – 28bar | 1.5bar | 34bar | Man. (Max.) |
RT 6AES | 10 – 28bar | 1.5bar | 34bar | Man. (Max.) |
RT 117E | 10 – 30bar | 1 – 4bar | 42bar | Auto |
Differential Pressure Switches for R717, HCFC, HFC and HC refrigerants:
Type | Regulating Range | Differential Dp | Operating Range for LP Bellows | Max. Working Pressure PS |
RT 260AE | 0.5 - 4bar | 0.3bar | -1.0 - 18bar | 22bar |
RT 260AE | 0.1 – 1.5bar | 0.1bar | -1.0 - 9bar | 11bar |
Thermostats:
Type | Regulating Range | Differential Dp | Max. Sensor Temperature | Type of Charge | Capillary Tube Length |
RT 9E | -45 - -15°C | 2.2 - 10°C | 1 – 4.5°C | 150°C | State Vapour | 5 |
RT 14E | -5 - 30°C | 2 - 8°C | 2 - 10°C | 150°C | Adsorption | 2 |
RT 14E | -5 - 30°C | 2 - 8°C | 2 - 10°C | 150°C | Adsorption | 5 |
RT 101E | 25 - 90°C | 2.4 - 10°C | 3.5 - 20°C | 300°C | Adsorption | 2 |
RT 101E | 25 - 90°C | 2.4 - 10°C | 3.5 - 20°C | 300°C | Adsorption | 5 |
RT 107E | 70 - 150°C | 6 - 25°C | 1.8 - 8°C | 215°C | Partial | 2 |
RT 107E | 70 - 150°C | 6 - 25°C | 1.8 - 8°C | 215°C | Partial | 5 |
RT 123E | 150 - 250°C | 6.5 - 30°C | 1.8 - 9°C | 300°C | Partial | 2 |
RT 123E | 150 - 250°C | 6.5 - 30°C | 1.8 - 9°C | 300°C | Partial | 5 |
Documents:
Data Sheet of Pressure Switch and Thermostat Type RT-E - AI240686442008en-000601 dated 2025.04
Declaration of Conformity dated 12.06.2025
This certificate replaces the previous certificate ELE086320XG/005