General Description:
Thermostat RAYSTAT–EX–02 is intended for temperature control of heating cables such as BTV, QTVR,
HTV and XTVR in hazardous areas.
- Enclosures
Body and lids: Laquered coated cast aluminum with stainless steel fittings and nitrile rubber internal lid seal.
Protection: IP65 if installed with Raychem cable glands GL-33 (armoured cable) or GL-34 (non armoured cable)
Lid fixing: Screw thread lid locked in place by a 2mm hexagonal key grub screw
Ambient operating temperature -40°C to +60°C
- Temperature sensing
Fluid filled bulb and capillary
Capillary 3 m long, bulb 197mm x 8 mm
Stainless steel (55316)
Exposure temperature -50 to +215°C
Max Capillary bend radius 15mm
- Switching
Single pole change over ( free voltage contact SPDT) ; Rating 22A @ 480Vac resistive loads
- Setting
Range: -4°C to 163°C ; Repeatability: ± 1,7 K; Differential: 5 K
Accuracy: (switch on): ±4.5°C at 21°C ambient and 50°C sensor temperature
- Connection terminals
Supply: 3 terminals for 1 to 4 mm2 ; Internal earth: single bolt for 1 to 4 mm2 conductors
External earth: single bolt and clamp for 1 to 4mm2 conductors
Reference documents:
- ATEX Certificate: 08 ATEX 6095X - Issue 7
Certification Authority: LCIE Bureau Veritas, Fontanay-aux-Roses (France)
Marking: II 2 G D, Ex db IIC T6 Gb, Ex tb IIIC T80°C Db IP 66
Safety Standard: EN 60079-0 (2012)+A11:2013; EN 60079-1 (2014) ; EN 60079-31 (2014)
- Data Sheet: RAYCHEM-DS-EU1427-TAYSTATEX02-EN
Remarks:
The Information listed in the present certificate are partial information based on the LCIE Certificates.
The component listed in this Certificate are to be used according to the manufacturer instructions:
Special conditions for safe use, according to the above referenced ATEX Certificate, are to be complied with.
The certificate supersedes previous RINA certificate No. ELE065119XG/005. |
|