Description:
OPTISWITCH 5300 C type VF534 vibrating level switches with tuning fork for point level detection of liquids.
Technical Data:
Process Temperature: -25°C - 450°C*
Process Pressure: -1 Bar - 160 Bar
Power Supply: 24 - 240V AC or 24V DC
Output Signal: Relay type, transistor type or 2-wire-type (8 / 16mA)
Environmental Category C, F, EMC1
*: For lower temperatures, see manufacturer´s specification
Type Designation:
VF534 . a b c dd e f g h i X j k
Legend:
a: Approval Directive / Scope
A, C, F, I, R, G, B, M
b: Approval
M, O, and other 1-digit alphanumeric codes for combination with several Ex-approvals*
c: Version
H, K, R
dd: Process Fitting
Thread, Flange
f: Second line of defense / Process Temperature
A, X
g: Electronics
I, L, R, S, T, Z
h: Housing
A, K, V
i: Cable entry
M, K, L, O, D, 6, N, I, P, 8, C, R, S, B, I, F, G, H, W and other equivalent entries/connections
j: Certificates
M, X
*: Ex-approvals are to be requested seperately (see manufacturer´s web-configurator)
See the technical documentation for detailed info on the designators.
TYPE APPROVAL CERTIFICATE
No. ELE143526XG
Enclosure - Page 2 of 3
Level Switch OPTISWITCH 5300 C
Reference documents:
Operation Instructions
- 48074-EN.pdf
- 48075-EN.pdf
- 48076-EN.pdf
- 48077-EN.pdf
- 48078-EN.pdf
- 48079-EN.pdf
Safety Manuals
- 51194-EN_Safety Manual R_SIL.pdf
- 51195-EN_Safety Maual Transistor_SIL.pdf
- 51196-EN_Safety Manual 2wire_SIL.pdff
Supplementary Tests
- 4-03_L _SIL_F1_Elmac_2013-3433-5360-RDEs_N_Aluminium Housing.pdf
- 4-03_L _SIL_F1_Elmac_2013-3433-5360-RDEs_Plastic Housing.pdf
- 4-04_L_SIL_F1_1_Alu-Geh_EN61000-4-4_Signal_coupling clamp_SIL.pdf
- 4-06_L_SIL_F1_1_EN61000-4-3_EN61326-2_AluGeh_Power Supply.pdf
- 4-06_L_SIL_F1_3_EN61000-4-3_EN61326-2_AluGeh_Grounding.pdf
- 4-06_Version L_SIL_F1_2_EN61000-4-6_Sensorltg_Dampfkesselzulassung_AluGe....pdf
- 4-06_Version L_SIL_F1_2_EN61000-4-6_Steam Boiler_Aluminium Housing.pdf
- 4-3_I_SIL_F1_Transistor version_Aluminium Housing.pdf
- 4-3_L_SIL_F1_1_Plastic Housing.pdf
- 4-3_L_SIL_F1_2_Aluminium Housing.pdf
- 4-3_S_SIL_F1_2013-3433-5361_Electronics_S_N_Aluminium Housing.pdf
- 4-3_S_SIL_F1_2013-3433-5361_Electronics_S_N_Plastic Housing.pdf
- 4-3_S_SIL_F1_2_Aluminium Housing.pdf
- 4-3_Version S_SIL_F1_3_Alu-Geh_Dampfkesselzulassung.pdf
- 4-4_I_SIL_F1_1_Electronics_I_on power supply.pdf
- 4-4_I_SIL_F1_2_Electronics_I_Transistor.pdf
- 4-4_S_SIL_F1_1_Electronics_S_Aluminuim Housing.pdf
- 4-6_I_SIL_F1_2_Electronics_I_additional Test for Steam Boiler Approval.pdf
- 4-6_I_SIL_F1_Electronics_I_Power Supply_Aluminium Housing.pdf
- 4-6_S_SIL_F1_1_Electronics_S_Aluminium Housing.pdf
- 4-6_S_SIL_F1_2_Electronics_S_Alu-Geh_additional Test for Steam Boiler Approval.pdf
TYPE APPROVAL CERTIFICATE
No. ELE143526XG
Enclosure - Page 3 of 3
Level Switch OPTISWITCH 5300 C
Test Reports_Hermes Hansecontrol and paconsult
- Paconsult 08-2268-Salt Mist Test representing Stainless Steel Housing.pdf
- Paconsult12-4518 Salt Mist Test for evaluation of Die Casting Housing Quality.pdf
- Paconsult 13-5074.pdf
- Paconsult 20-13294G
- Hermes Hansecontrol_13-L-00895-01R_EMC.pdf
- Hermes Hansecontrol_13-L-00896-01R_EMC.pdf
- Hermes Hansecontrol_13-L-00897-01R_EMC.pdf
- Hermes Hansecontrol_2001-0246001R08
VEGA Inhouse Test Reports
- 1-05_ OPTISWITCH 5300 C. (compact version).pdf
- 1-05_ OPTISWITCH 5300 C.-R_F4_1_Vibration-Sinus 1g_Ship_longer sensors.pdf
- 1-05_ OPTISWITCH 5300 C. standard version (with tube extension =500 mm).pdf
- 1-09_SIL_F1_1_Flammability Test_Plastic Housing.pdf
- 1-09_OPTISWITCH 5300 C_F4_1_Flammability Test.pdf
- 1-10_OPTISWITCH 5300 C_R_F4_1_PED
- 3-04_OPTISWITCH 5300 C-R_F4_1_Pressure Resistance
- 4-6_ OPTISWITCH 5300 C.T_F2_6_Steam Boiler Approval_Plastic Housing_screened cable.pdf
- Functional Test in liquid Nitrogen 2x8h_20131203.pdf
Remarks:
This approval is granted only on the basis of positive outcome of verifications on board to be carried out according to all above mentioned remarks and installation instructions as well as to all other applicable RINA Rules. |
|