General Description:
Halogen free, low smoke, shipboard instrumentation, control and telecommunication cables.
Rated voltage: 150/250 V
Type: NTKOXSekw 150/250 V (300 V)
NTKOXSekf/ekw 150/250 V (300 V)
FLAME-X 950 NTKOGsekw 150/250 V (300 V)
Marking: TF KABLE 1 - type - n X size - 150/250 V - IEC 60332-3 cat. A - year
Construction:
a.) conductor:
- circular stranded bare or tinned copper class 2 or 5 (NTKOXSekw and NTKOXSekf/ekw), acc. to IEC 60228;
- circular stranded bare or tinned copper class 2 (NTKOGsekw), acc. to IEC 60228.
b.) insulation:
- cross-linked polyethylene XLPE (NTKOXSekw and NTKOXSekf/ekw), acc. to IEC 60092-360,
- special cross-linked compound S 95 (NTKOGsekw), acc. to IEC 60092-360;
c.) inner covering: tape or extruded inner bedding (optional);
d.) screen: copper wire braiding with the metallic contact with a copper drain wire (optional);
e.) sheath: thermoplastic halogen free polyolefin compound type SHF1, acc. to IEC 60092-360;
f.) max. conductor temperature: 90°C;
g.) min. installation temperature: -15°C;
h.) fire resistance: NTKOGsekw only.
i.) conductor sizes: as per cable catalogue cards.
International standards:
IEC 60092-350:2020, IEC 60092-360:2021, IEC 60092-376:2025, IEC 60332-1-2:2025, IEC 60332-3-22 Cat. A (Ed. 1.1: 2009), IEC 60228:2023, IEC 60754-1:2019, IEC 60754-2:2019, IEC 61034-1 (Ed. 3.0: 2005), IEC 61034-2:2019,
IEC 60331-1:2018.
Technical specifications:
- NTKOXSekw: TT1-6347 v.6 14.06.2016,
- NTKOXSekf/ekw: TT1-6840 06.11.2015,
- NTKOGsekw: TT1-6407 v.5 09.01.2017.
Additional documentation:
Declaration ELE117821XP_001 dated 10.08.2026..pdf
The certificate annuls and supersedes the previous RINA certificate No. ELE117821/001. |
|