Bulkhead composed of two side by side bulkheads installed with, in between, a minimum air gap of 20 mm.
Each bulkhead, consisting of panels having height of 2500 mm and width of 600 mm, is composed starting to the side exposed to the fire of a steel sheet 0,7 mm thick and a steel sheet of 0,3 mm thick on the internal side. In between a mineral wool layer, 25 mm thick and having density of 100 kg/m3 named ULTIMATE U SEA PROTECT produced by SAINT-GOBAIN ISOVER (density of 100 kg/m3) or Rockwool SEAROX SL-420 WAV (density of 120 kg/m3) produced by ROCKWOOL is fitted and glued by means of 110 g/m2 of adhesive ICEMA 145/75. The joints between the panels are made by "L" steel profile bending on the edge of the blades with their respective joints and covered by two steel sheet boxed profile having length of 800 mm each, pitch of 470 mm and dimensions of 52,5x26,6 mm and thickness of 0,6 mm. Between omega and boxed profile a stripe of material type PROMAFLEX GM having dimensions of 2350x120 mm and thickness of 3 mm is fitted. The bulkhead made up of the aforementioned panels is provided on the perimeter of a āCā steel profiles 1,2 mm thick with dimensions of 33,5 x 21,5 mm, screwed to the panels on the exposed side to the fire, with pitch of 300 mm on lateral side and 200 mm on upper and lower side. Finaly the panels are provided on the perimeter of two opposing āLā profiles with dimensions of 70 x 30 mm and thickness of 2 mm fixed by tack welded on the bulkhead. Field of application Fire resisting B-15 Class bulkhead for general application.Reference documents De Wave drawing No. DC-01-K1-69 dated 10 May 2019, No. C-01-K1-69 Rev.00 dated 18 July 2020 and No. C-01-K1-42 dated 10 May 2019 approved on 12 April 2021, on 28 July 2020 and on 12 March 2020 respectively with endorsement No. LABS-2217, No. LABS-2063 and No. LABS-2005.Tests carried out Tests as per RINA Test Laboratory reports No. 2020CS012316/1 issued on 28 July 2020 and No. 2019CS011692/1 dated 12 March 2020 according to IMO 2010 FTP Code. |