1. Production Description:
+ 150/250V shipboard control cables with following rating:
Type | Rated
Voltage (V) | Number of Core | Conductor
Cross-Section (mm2) | Max. Temp. (°C) |
CKJPJ、CKJPF、CKJ85、CKJ86、
CKJPF86、CKJPJ85、
CKJPF96、CKJPJ95、
CKJPF80、CKJPF90、CKJPJ80、CKJPJ90、
CKJPPJ、CKJPPF、CKJP85、CKJP86、
CKJPPF86、CKJPPJ85、
CKJPPF96、CKJPPJ95、
CKJPPF80、CKJPPF90、CKJPPJ80、CKJPPJ90
/DC, SC, NC(NSC), DA, SA, NA(NSA) | 150/250V
| 2~37
(See
Note )
| 0.75, 1.0,
1.5, 2.5
| 90 |
Note: “Number of Core” is selected from the following series of core number: 2, 4, 7, 12, 14, 19, 27, 37.
+Abbreviation:
CK: Product Series Code
J: Cross-linked Polyethylene Insulated
PJ: Cross-linked Polyolefin
PF: Polyolefin
P: Individual Screen
+Outer Protection:
8: Copper wire Braid
9: Galvanized steel wire braided
5: Cross-linked Polyolefin outer sheath (SHF2)
6: Thermal plastic Polyolefin outer sheath (SHF1)
0: Without outer sheath
TYPE APPROVAL CERTIFICATE |
No. ELE567024WS/002 |
Enclosure - Page 2 of 2 |
+Flammability Code:
DA: Single Core Flame Retardant
SA: Bunched Flame Retardant
NA(NSA): Bunched Flame Retardant and Fire Resistant
DC: Single Core Flame Retardant, Low Smoke, Halogen-Free
SC: Bunched Flame Retardant, Low Smoke, Halogen-Free
NC(NSC): Bunched Flame Retardant, Fire Resistant, Low Smoke, Halogen-Free
2. Reference Documents:
+ Specification of marine cables. Filed by RINA with drawing No. SHEL-23003.
+ Test Report: “Shanghai National center of testing and inspection for electrical cables and wire Co., Ltd” Report No.: CT23-03484-2GY1 and CT23-03484-1GY1. Filed by RINA with drawing No. SHEL-23006.
+ Routine test Report and Narrative report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-23005.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-223000.
+ Manufacturer's information, Filed by RINA with drawing No. SHEL-22001.
3. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment. |
|