Single leaf hinged door whose maximum clear opening size is 800 mm wide and 1800 mm high. The door leaf, having maximum width of 864 mm, height of 1864 mm and thickness of 111 mm, is composed moving from the exposed side, of a 3 mm thick carbon steel plate, an 8 mm thick layer of inorganic fireproof board, four layers of ceramic fiber thick 20 mm each, a 8 mm thick layer of inorganic fireproof board and an 8 mm thick carbon steel plate having the edges bended to the rabbet. Between the two steel plates are provided stiffeners, welded to the 8 mm thick steel plate, composed by four horizontal “L” steel profiles 50x50x6 mm and one vertical steel plate 50x9 mm. The 3 mm thick steel plate is fixed with 26 screws M6x12mm. Inside the leaf is fitted an insulation composed by two external layer of inorganic fireproof board (certified not combustible in conformity to the requirements of the IMO FTP Code), with a thickness of 8 mm each having density of 1200 kg/m3 and between them four layers of ceramic fiber (certified not combustible in conformity to the requirements of the IMO FTP Code), 20 mm thick each having density of 170 kg/m3. The door frame, welded to the unexposed side of the bulkhead, is composed by a carbon steel “L” profile having dimensions of 100x100x10 mm and a carbon steel “L” profile 38x25x6 mm on which, in the inner side, are provided fireproof sealing strips 38x4 mm provided by Shanghai Jiar Fu Decoration Material Company Ltd; on the lateral side are installed three steel hinges. The door is equipped with a lever closing device that acts on six points, fitted on the side exposed to the fire and actuated by a handle. The closure is made tight with flame retardant gaskets, provided by Jiangyin Haida-Rubber And Plastic Co., Ltd, having dimensions of 38x20 mm fitted along the perimeter between the frame and the leaf rabbet.
Field of application Fire resistant A-60 Class single leaf hinged door in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and with of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in each door leaf
- maximum door size tested
- door used with a fire tested frame design
Reference documents Nanjing Lishui Yisheng Ship Fitting Factory drawing No. 124YS01-19-00-NHSG attached to the Far East Fire Testing Centre (FEFTC) Test Report No. FT12252 issued on 17 October 2012.
Tests carried out Tests as per Far East Fire Testing Centre (FEFTC) Test Report No. FT12252 issued on 17 October 2012 according to 2010 FTP Code Annex 1, Part 3. |