ELE171625CS!002ENGD- -  -  N- SH-CI-I-U, SH-CI-I-U SHF2, SH-CI-I-A, SH-CI-I-A SHF2, SH-CI-C-U, SH-CI-C-U SHF2, SH-CI-C-A, SH-CI-C-A EMC, SH-CI-C-A SHF2, SH-CI-C-A SHF2 EMC, SH-CI-U-A, SH-CI-U-A SHF2, SH-CI-U-U, SH-CI-U-U SHF2, SH-CI-IC-U, SH-CI-IC-U SHF2, SH-CI-IC-A, SH-CI-IC-A EMC, SH-CI-IC-A SHF2, SH-CI-IC-A SHF2 EMC, 150/250 V (300V) -N- S- S- -13/01/2025- Prodotti Elettrici- - SN- N- Luigi Benedetti- N-  - 192,935Luigi BenedettiBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE171625CS/002- N-Jan 13, 2030192935
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE171625CS/002 - (ENG)
Certificate date 13/01/2025
Type Impianti Elettrici
Product CAVI ELETTRICI

Model or Denomin.
Items
SH-CI-I-U, SH-CI-I-U SHF2, SH-CI-I-A, SH-CI-I-A SHF2, SH-CI-C-U, SH-CI-C-U SHF2, SH-CI-C-A, SH-CI-C-A EMC, SH-CI-C-A SHF2, SH-CI-C-A SHF2 EMC, SH-CI-U-A, SH-CI-U-A SHF2, SH-CI-U-U, SH-CI-U-U SHF2, SH-CI-IC-U, SH-CI-IC-U SHF2, SH-CI-IC-A, SH-CI-IC-A EMC, SH-CI-IC-A SHF2, SH-CI-IC-A SHF2 EMC, 150/250 V (300V)
Applicant UNIKA S.P.A.
Place of requester VIA LOMBARDIA, 15  %  37044 COLOGNA VENETA (VR)  % ITALY
Tel. N.,Fax, Email 0442 411791, 0442 419350, Giuseppe.demaria@unika.it
Standards RINA Rules for the Classification of Ships Pt C, Ch 2, Sec 9,IEC Standards (see Enclosure)
Expire date 13/01/2030
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE171625CS/002
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC CABLES
Type SH-CI-I-U, SH-CI-I-U SHF2, SH-CI-I-A, SH-CI-I-A SHF2, SH-CI-C-U, SH-CI-C-U
SHF2, SH-CI-C-A, SH-CI-C-A EMC, SH-CI-C-A SHF2, SH-CI-C-A SHF2 EMC, SH-CI-U-A,
SH-CI-U-A SHF2, SH-CI-U-U, SH-CI-U-U SHF2, SH-CI-IC-U, SH-CI-IC-U SHF2,
SH-CI-IC-A, SH-CI-IC-A EMC, SH-CI-IC-A SHF2, SH-CI-IC-A SHF2 EMC, 150/250 V
(300V)

Applicant UNIKA S.P.A.
VIA LOMBARDIA, 15
37044 COLOGNA VENETA (VR)
ITALY
Reference standards RINA Rules for the Classification of Ships Pt C, Ch 2, Sec 9,IEC Standards (see Enclosure)
  

 
 
   .   This Certificate is valid until January 13, 2030
_________________________________
RINA Services S.p.A.
Luigi Benedetti
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE171625CS/002
Enclosure - Page 1 of 1
SH-CI-I-U, SH-CI-I-U SHF2, SH-CI-I-A, SH-CI-I-A SHF2, SH-CI-C-U, SH-CI-C-U SHF2, SH-CI-C-A, SH-CI-C-A EMC, SH-CI-C-A SHF2, SH-CI-C-A SHF2 EMC, SH-CI-U-A, SH-CI-U-A SHF2, SH-CI-U-U, SH-CI-U-U SHF2, SH-CI-IC-U, SH-CI-IC-U SHF2, SH-CI-IC-A, SH-CI-IC-A EMC, SH-CI-IC-A SHF2, SH-CI-IC-A SHF2 EMC, 150/250 V (300V)
Materials/Components

Control and instrumentation cables:
unscreened, individually screened & collectively screened ,
armoured & unarmoured , low smoke, halogen free, for ships and offshore units.

Rated voltage: 150/250 V (300 V)
Type:

Sheath
SHF1SH-CI-I-U
SHF2SH-CI-I-U SHF2
SHF1SH-CI-C-U
SHF2SH-CI-C-U SHF2
SHF1SH-CI-I-A
SHF2SH-CI-I-A SHF2.
SHF1SH-CI-C-A; SH-CI-C-A EMC
SHF2SH-CI-C-A SHF2; SH-CI-C-A SHF2 EMC
SHF1SH-CI-U-A.
SHF2SH-CI-U-A SHF2.
SHF1SH-CI-U-U.
SHF2SH-CI-U-U SHF2.
SHF1SH-CI-IC-U
SHF2SH-CI-IC-U SHF2
SHF1SH-CI-IC-A; SH-CI-IC-A EMC
SHF2SH-CI-IC-A SHF2; SH-CI-IC-A SHF2 EMC

Maximum conductor temperature: 90°C

Marking:
UNIKA (Italy) - XX-XX-X-X (*) (EMC for EMC version) (SHF2 for SHF2 version) - 150/250 V - 90°C - (core number) x (cross-section) - IEC 60092-376 - IEC 60332-3-22 - treaceability code -meter marking

XX-XX-X-X (*)
SH-CI-I-U
SH-CI-C-U
SH-CI-I-A
SH-CI-C-A
SH-CI-U-A
SH-CI-U-U
SH-CI-IC-U
SH-CI-IC-A




Construction:
All Cable TypeConductor: bare or tinned copper conductor (according to IEC 60228 class 2 or class 5) or class 6)
insulation: HF-XLPE or HEPR

Single core assembly: each core assembled forming pairs or triples or quads (unit)
individual screen on each unit: aluminum/polyester or copper tape with drain wire (optional bare or tinned copper wire braid)

Unit Assembly: all units assembled in round formation with suitable fillers and non-hygroscopic tape(s)

Sheath: SHF1 or SHF2


SH-CI-I-A
SH-CI-IC-UIndividual screen on each unit: aluminium/polyester or copper tape with drain wire
SH-CI-C-U
SH-CI-IC-U
SH-CI-IC-ACollective screen: aliminium/polyester tape with drain wire
SH-CI-C-ACollective screen: aluminium/polyester tape with drain wire, aluminium or copper tapes for EMC version
SH-CI-C-A
SH-CI-IC-A
SH-CI-I-ANon hygroscopic tape(s)
SH-CI-I-A
SH-CI-C-A
SH-CI-U-A
SH-CI-IC-AArmouring: bare copper braid or tinned copper or galvanized steel wire braid

In accordance with: IEC 60228; IEC 60092-350; IEC 60092-376; IEC 60092-360; IEC 60332-1; IEC 60332-3-22 Cat.A; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2; RINA Rules for Ships; RINAMIL Rules; RINA Rules for FSRU; RINAMIL for FREMM.

Low temperature behaviour up to -50 °C according IEC 60811 - 504/505/506 for cable with SHF2 Sheat.
UV Resistance according UL 758 (720h) for SHF1 & SHF 2 Sheat

Tecnichal specification:
Data Sheet UNIKA N. 003 - 004 Rev.0, UNIKA N. 004 Rev.0 ; UNIKA N. 005 Rev.0; UNIKA N. 006 Rev.0; UNIKA N. 007 Rev.0; UNIKA N.008 Rev.0; UNIKA N.010 Rev.0 dated 07/08/2019
Minimum installation temperature: -15°C (-40°C with SHF2 sheath, according to IEC 60092-350 ann.E).
(SH-CI-C-A / SH-CI-IC-A) For EMC version only: transfer impedance ≤ 25 mohm/m (0-100 MHz) according to IEC 62153-4-3
Drilling fluid resistance according to IEC 60092-360 Tab.9-10 with sheath SHF2.
Low temperature behaviour up to -50 °C according IEC 60811 - 504/505/506 for cable with SHF2 Sheath
UV Resistance according UL 758 (720h) for SHF1 & SHF 2 Sheath

Test Reports:
IMQ N. CN14S0264212-01 dated 2014/06/12.
IMQ N. CN16-0006795-01 dated January 24, 2017.
UNIKA N. 001.2014 dated 2014/06/11 witnessed by RINA.
UNIKA n° TR 03-2025 dated 30/01/2025
UNIKA n° TR 012a-2024 dated 11/06/2024
UNIKA n° TR 012b-2024 dated 11/06/2024
IMQ N° CN25-0113126-01-TR dated 22/01/2025





Reference documents
TAO-APP dated 30/01/2025
Offer 2025/9993 dated 03/04/2025
The documents above-mentioned have been archived in the Leonardo Draw Plus portal under the project:
https://leodrawplus.rina.org/projects/57625/detail

Genoa June 25, 2025
**** NOTICE: This is NOT an official certificate ****