ELE340626XT!009ENG- -  -  N- MGCH-FFR 0.6/1 kV -N- S- S- -13/10/2026- Prodotti Elettrici- - SN- N- - N-  - 369,823BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE340626XT/009- N-Oct 14, 2031369823
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE340626XT/009 - (ENG)
Certificate date 13/10/2026
Type Impianti Elettrici
Product CAVI ELETTRICI

Model or Denomin.
Items
MGCH-FFR 0.6/1 kV
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Place of requester MAKINE O.S.B. 6.CADDE, NO.4 DILOVASI  %  41455 KOCAELI  % TURKEY
Tel. N.,Fax, Email +90 262 722 9330, +90 262 722 9443, erdogan.malkoc@untel.com.tr
Standards DIN 89158, IEC 60092-350,IEC 60331-21
Expire date 14/10/2031
Head Office ISTANBUL
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE340626XT/009
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC CABLES
Type MGCH-FFR 0.6/1 kV
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Reference standards DIN 89158, IEC 60092-350,IEC 60331-21
  

 
 
   .   This Certificate is valid until October 14, 2031
_________________________________
RINA Services S.p.A.
Oytun Uzun
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE340626XT/009
Enclosure - Page 1 of 1
MGCH-FFR 0.6/1 kV
Materials/Components

Shipboard power cables, flame retardant, fire resistant, halogen free with low smoke emission, for ships and off-shore units installation.

Rated voltage: 0.6/1 kV

Type: MGCH-FFR

Marking: UNTEL DIN 89158 IEC 60092-353 MGCH-FFR n x s mm2 0.6/1 kV IEC 60332/3A IEC 60331


Construction:
conductor: stranded copper wire class 2 or 5, tinned on request

mica tape on the conductor
insulation: HF-EPR
bedding: halogen free compound
screen: plain copper braid wires tinned on request
sheath: SHF1

Max. conductor temperature: 90°C.

In accordance to rules DIN 89158; IEC 60228 ; IEC 60092-350; IEC 60092-353; IEC 60092-360; IEC 60331-21; IEC 60332-1-2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2.


Conductor size:

number of cores 1 - cross sectional area from 1.5 to 300 mm2
number of cores 2, 3, 4 - cross sectional area from 1 to 300 mm2
number of cores 5 - cross sectional area from 1 to 240 mm2
number of cores 7 - cross sectional area from 1 to 4 mm2
number of cores 10,12,14,16, 18, 19, 20, 21, 24, 25, 27, 30, 32, 34, 36, 37 - cross sectional
area from 1 to 2.5 mm2

Technical specification: data sheet N. FR 70-051 Rev1 dated 01/07/2011.



ISTANBUL 14/10/2026