ELE451425CSENGB- -  -  N- X-COM 3: modular data communication units -N- S- S- -11/12/2025- Prodotti Elettrici- - SN- N- Luigi Benedetti- N-  - 840,830Luigi BenedettiBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE451425CS- N-Dec 11, 2030840830
 
Form
  Prodotti Elettrici(TO)
ELE451425CS
Certification N. ELE451425CS - (ENG)
Certificate date 11/12/2025
Type Impianti di Automazione
Product Sistema di comando e controllo

Model or Denomin.
Items
X-COM 3:  modular data communication units
Applicant NACOS MARINE APSS S.R.L.
Place of requester VIA SAN SEBASTIANO, 16  %  12055 Diano D'Alba (CN)  % ITALY
Tel. N.,Fax, Email 0173 468468, 0173 468469, ---
Standards RINA Rules for the Classification of Ships Part C, - Machinery , Systems and Fire Protection - Ch. 3,Sect. 6,Tab. 1
Expire date 11/12/2030
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE451425CS
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Control and monitoring system
Type X-COM 3:  modular data communication units
Applicant NACOS MARINE APSS S.R.L.
VIA SAN SEBASTIANO, 16
12055 Diano D'Alba (CN)
ITALY
Reference standards RINA Rules for the Classification of Ships Part C, - Machinery , Systems and Fire Protection - Ch. 3,Sect. 8,Tab. 1
  

 
 
   .   This Certificate is valid until December 11, 2030
_________________________________
RINA Services S.p.A.
Luigi Benedetti
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE451425CS
Enclosure - Page 1 of 1
X-COM 3:  modular data communication units
System description

X-COM3 is a gateway data concentrator for RS485 and Ethernet connections. It has an optic-insulation of internal logic and serial lines from other serial lines and external power supply.

Motherboards MCU2-MB-XCH-X are available in different size, to allow the connection
of one up to four or ten modules:

X-COM 3 Data Concentrator unit and Communication module:
- two inputs from power supply, main and reserve. (18_32Vdc)
- includes 5x RS485 Serial Lines and 2x Ethernet ports 10/100 Network Interface LAN 1 and LAN 2.
- serial lines are optoisolated from each other and from the power supply
- LED indication for link activity, power supply, card watch dog.

Firmware for X-COM 3 module: Ver. V2.x

X-COM 3 is used to interfaced MCU I/O cards to the automation system through RS485 Serial line

Technical specifications:

Power Supply 18-32 Vdc Redundant
Power Consumption 2.8 W
Power supply supervision Yes
Communication 5 x RS485 and 2 x Ethernet
Installation DIN rail via motherboard

X-COM3-002 Technical Manual Rev. 4 (24/07/2025)
X-COM3-002 Datasheet Rev. 1 (24/07/2025)

Test reports:

TESLAB Report n. 20A248E (12/11/2020) (performance test for EMC Radiated immunity up to 6 GHz)
TESLAB Report n. 147113F rev1. (25-08-2015)

Reference Documents:
ISO 9001:2015 Certificate No. C672907 (Valid 07/2025 - 12/2026)
Offer 2025/25175
The documents above-mentioned have been archived in the Leonardo Draw Plus portal under the project:
https://leodrawplus.rina.org/projects/69428/detail
This Certificates annuls and replaces the previous Certificate No. ELE314320CS001.
Validity of this certificate is subject to satisfactory outcome of yearly audit as per RINA " Rules for Testing and Certification of Marine Materials and Equipment".


Genoa December 11, 2025