Product description:
The SaCoS 5000 system is utilized as control, alarm and safety system for the management of all 4-stroke internal combustion engine types developed by MAN Diesel & Turbo SE for marine propulsion, genset, naval, offshore applications and SCR systems.
The SaCoS 5000 system involve the following modules with separate certificates:
Module types:
• Control Module (CM)
• Control Module Plus (CM+)
• CAN Repeater Module (CRM)
• Display Module Large (DML)
• Gateway Module (GCM)
• Injection Module (IM)
• Injection Module Plus (IM+)
• Cylinder Pressure Module (CPM)
• Knock Control Module (KCM)
Control Unit:
• Mounted on engine
• Consist of 2 independent control modules (alarm and safety system)
• Complete engine sensors and actuators
Injection Unit:
• Mounted on engine
• Consist of 1 or 2 injection modules, depending on application
• Redundant for single propulsion
• For common rail / dual fuel applications
• Connected to common rail related sensors and injectors
• Connected to control unit via redundant bus system
Local Operating Panel:
• Mounted on engine
• Consist of 1 or 2 touch screens depending on application
• Emergency control via separate buttons
• Connected to control unit and interface cabinet via bus or ethernet
Remote Operating Panel:
• Touch screen, functions are comparable to local operation panel
• Emergency control via separate buttons
• Connected to interface cabinet via bus or ethernet
• Optional panel, depending to application requirements
Interface / Auxiliary Cabinet:
• Interface and auxiliary cabinet stand alone at flexible locations
• Consist of PLC for communication, power supply components and devices for pumps and other auxiliary systems
• Application specific design
Redundancy:
• Redundant power supply 24V DC
• Fully redundant electronic fuel injection
• Redundant sensors
• Redundant control bus
• Redundant gateway
• Back-up operating panel
TYPE APPROVAL CERTIFICATE |
No. ELE277523XG |
Enclosure - Page 2 of 2 |
SaCoS 5000 System |
Documents:
Descriptions: - 01-1,1,SaCoS 5000 System,Documentation,V1.0; 01-2 SaCoS Safety Stop Concept V2,2,EN,Released; 01-2.1,Safety Stop Architecture ERA S5K ,en; 04-1 SaCoS.Common.HW.ProductSpec,en; 04-2 SaCoS.HW.IM,E1,ProductSpec,en; 04-3 SaCoS5000.DML,2.x,GCM,2.x.HW,ProductSpec,Internal,EN; 04-4 SaCoS.HW.CM,E1,ProductSpec,en; 04-5 SaCoS5000.HW.CRM,,ProductSpec,internal,en; 04-6 SaCoS.5000.BSB.ProductSpec,en; 05-1,S5K,49-60DF,6-5-1-0,M,OI,EN,V3.0; 05-2,S5K,32-44CR,8-5-0-0,M,OI,EN,V1.1; 05-3,S5K,ERA,100-5.0.0,IMI,EN,V1.0;
Drawings: - 01-2,2,SaCoS,5000,Safety-Design,Overview-Sketch,Marine-Plant,Medium,Speed,,Large-Bore,V1.5.5, (2021-12-15),EN; 01-2,3,Safety,Stop,Design,S5K,ERA;,Medium,Speed,,Large,Bore,,Marine,Application,V1.0.3,
(2022-03-28),EN; 02-1 LMC,master,S5k,6,5.0.0-RC7.1,4960DF,2021-11-15; 02-2 LMC,master,S5k,6,5.0.0-RC7.1, 3244CR,2021-11-15; 2.5,Safety,Stop,Design;,S5K,Release,10-5.0.0;,High,Speed,,Marine,Application,V1.8.1,(2023-06-20),EN; 02-1 LMC,master,S5k,10,5.0.0-175D,2021-11-15; 03-1,SaCoS,5000,,Power,Supply,Overview, Large-Bore,Marine,V2.3.0,(2021-06-14); 03,02,MAN,175D,S5K,Power,Supply,Overview,V5.0.2,(2023-02-24); 06-10-32,44,Control,Unit,DRW,HW9103,5-1-2; 06-11-32,44,Driver,Cabinet,DRW,HW5165,5-1-2HF1; 06-12-32,44,Injection,Unit,DRW,HW9105,5-1-2; 06-13-32,44,Injection,Unit,Singel,Prop,DRW,HW9107,5-1-2HF1; 06-14-32,44,Interface,Cabinet,DRW,HW5080,5-0-0; 06-15-32,44,Local,Operating,Panel,DRW,HW9101,5-1-2; 06-16-32,44,Remote Operating Panel,DRW,HW9987,5-1-2; 06-17-32,44,Wheelhouse,Operating,Panel,DRW,HW9989,5-1-2; 06-18-32,44,Data,Logging,Cabinet,DRW,HW0146,3-0-0HF3; 06-19-ERA,Cabinet,HW5041,5-0-0; 06-20-49,60,Auxiliary Cabinet,DRW,HW5050,5-2-0; 06-21-49,60,Control,Unit,DRW,HW9103,5-1-2; 06-22-49,60,Driver,Cabinet,DRW,HW5165,5-2-0; 06-23-49,60,Gas,valve,Unit,Cabinet,DRW,KS5071A,5-1-1; 06-24-49,60,Injection,Unit,HW9105,5-1-2,IM1; 06-25-49,60,Injection,Unit,Single,Prop,HW9107,5-1-2HF1; 06-26-49,60,Interface,Cabinet,HW5035,5-2-0; 06-27-49,60,Remote,Operating,Panel,HW9987,5-1-2; 06-28-49,60,Wheelhouse,Operating,Panel,HW9989,5-1-2; 06-29-49,60,Combustion,Control,Unit,HW9108,5-1-2; 06-30-49,60,Knock,Control,Unit,HW9109,5-1-2; 06-31-49,60,Local,Operating,PanelHW9101,5-1-1; 06,1,4960DF,1133000-6-5.1.0.SaCoS5000,HWSysArchitecture,1.0.2; 06,2,4960DF,6-5.2.0.SaCoS5000,HWSysArchitecture,1.0.2; 06,3,SaCoS,EEA,HW-System-Architecture,Rel.X.x.x,v.0.0.3; 06,4,3244CR.SaCoS5000,HWSysArchitecture,1.0.4; 06,5,175d,HWSysArchitecture,175D,10-5.0.0; 06-32-HW5182,5-1-0,CU (2); 06-33-HW5189,5-0-0,EC; 06-34-HW5184,5-0-0,ROP; 06-35-HW5186,5-0-0,WOP; 06-36-HW5183,5-0-1,LOP; 06,05,175D,10-5.0.0,SaCoS5000,HWSysArchitecture,1.0.4; 06-12-32,44,Injection,Unit,DRW,HW9105,5-1-2; 06-15-32,44,Local,Operating,Panel,DRW,HW9101,5-1-2; 06-18-32,44,Data,Logging,Cabinet,DRW,HW0146,3-0-0HF3; 06-20-49,60,Auxiliary Cabinet,DRW,HW5050,5-2-0; 06-21-49,60,Control,Unit,DRW,HW9103,5-1-2; 06-23-49,60,Gas,valve,Unit,Cabinet,DRW,KS5071A,5-1-1; 06-24-49,60,Injection,Unit,HW9105,5-1-2,IM1; 06-26-49,60,Interface,Cabinet,HW5035,5-2-0; 06-29-49,60,Combustion,Control,Unit,HW9108,5-1-2; 06-30-49,60,Knock,Control,Unit,HW9109,5-1-2; 06-32-HW5182,5-1-0,CU (2); 06-33-HW5189,5-0-0,EC;
Software: - 07-02 Software,Versioning,Version1.8; 07-1 Basic-design-principles,application-software,SaCoS,5000; 07-3 EEDSB.MAN,SaCoS.SW,DDS,EN; 07-4 DDS,Firmware,Build,Projects; 07-5 SaCoS,5000,CoDeSys,Library,Documentation,,Framework,Basic,LIB,ALM; 07-6 SaCoS,5000,CoDeSys,Library,Documentation,,Framework,Basic,LIB,OPV; 07-7 SaCoS,Function overviews,Customer-Licensees,EN; 07-8 S5k,8-5.0.0,Integration,Component,Distribution,List; x 07-9 SaCoS 5000 Product Structur Version List;
FMEA: - 08-01-FMEA S5K LB M V1,0 en Upd02; 08-02-FMEA ERA LB M V1,0 en Upd00;
Test reports:
Protocols: - 09-2 Integrationstest SaCoS5000 Denamark_Class Approval 091023; 2023-02-06_Signed Type Approval Test - SaCoS 5000 System; 2023-03-21_49_60_l-SafetyIntegrationTest_signed-ocr
Remarks:
- Approval valid for ships intended to be granted with the following additional class notations: AUT-UMS, AUT-CCS and AUT-PORT.
- The system is suitable as a crankcase monitoring device in connection with monitoring of main bearings.
- Documents relating to each application are to be submitted to the Society's examination prior fitting on board.
- All changes in software and hardware are to be recorded as long as the system is in use on board.
- The records of all changes are to be forwarded to RINA for evaluation and approval.
- Major changes in the software / firmware are to be approved before being installed on the programmed systems. |
|