ELE277523XGENG- -  -  N- SaCoS 5000 System -N- S- S- -13/03/2024- Prodotti Elettrici- - SN- N- Giuseppe Russo- N-  - 736,608Giuseppe RussoBbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE277523XG- N-Mar 12, 2029736608
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE277523XG - (ENG)
Certificate date 13/03/2024
Type Impianti di Automazione
Product Sistema di sicurezza, comando e monitoraggio motori diesel

Model or Denomin.
Items
SaCoS 5000 System
Applicant MAN DIESEL & TURBO SE
Place of requester STADTBACHSTRASSE 1  %  86153 AUGSBURG  % GERMANY
Tel. N.,Fax, Email 0049 821 322 0, 0049 821 322 3382, ---
Standards Rules for the classification of ships.- Part C - Machinery, systems and fire protection. - Ch.3, Sect. 6, Table 1.
Expire date 12/03/2029
Head Office Hamburg
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE277523XG
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Diesel engine safety, control and monitoring system
Type SaCoS 5000 System
Applicant MAN DIESEL & TURBO SE
STADTBACHSTRASSE 1
86153 AUGSBURG
GERMANY
Reference standards Rules for the classification of ships.- Part C - Machinery, systems and fire protection. - Ch.3, Sect. 6, Table 1.
  

 
 
   .   This Certificate is valid until March 12, 2029
_________________________________
RINA Services S.p.A.
Giuseppe Russo
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE277523XG
Enclosure - Page 1 of 2
SaCoS 5000 System
Product description:
The SaCoS 5000 system is utilized as control, alarm and safety system for the management of all 4-stroke internal combustion engine types developed by MAN Diesel & Turbo SE for marine propulsion, genset, naval, offshore applications and SCR systems.

The SaCoS 5000 system involve the following modules with separate certificates:
Module types:
• Control Module (CM)
• Control Module Plus (CM+)
• CAN Repeater Module (CRM)
• Display Module Large (DML)
• Gateway Module (GCM)
• Injection Module (IM)
• Injection Module Plus (IM+)
• Cylinder Pressure Module (CPM)
• Knock Control Module (KCM)

Control Unit:
• Mounted on engine
• Consist of 2 independent control modules (alarm and safety system)
• Complete engine sensors and actuators

Injection Unit:
• Mounted on engine
• Consist of 1 or 2 injection modules, depending on application
• Redundant for single propulsion
• For common rail / dual fuel applications
• Connected to common rail related sensors and injectors
• Connected to control unit via redundant bus system

Local Operating Panel:
• Mounted on engine
• Consist of 1 or 2 touch screens depending on application
• Emergency control via separate buttons
• Connected to control unit and interface cabinet via bus or ethernet

Remote Operating Panel:
• Touch screen, functions are comparable to local operation panel
• Emergency control via separate buttons
• Connected to interface cabinet via bus or ethernet
• Optional panel, depending to application requirements

Interface / Auxiliary Cabinet:
• Interface and auxiliary cabinet stand alone at flexible locations
• Consist of PLC for communication, power supply components and devices for pumps and other auxiliary systems
• Application specific design

Redundancy:
• Redundant power supply 24V DC
• Fully redundant electronic fuel injection
• Redundant sensors
• Redundant control bus
• Redundant gateway
• Back-up operating panel


TYPE APPROVAL CERTIFICATE
No. ELE277523XG
Enclosure - Page 2 of 2
SaCoS 5000 System

Documents:
Descriptions: - 01-1,1,SaCoS 5000 System,Documentation,V1.0; 01-2 SaCoS Safety Stop Concept V2,2,EN,Released; 01-2.1,Safety Stop Architecture ERA S5K ,en; 04-1 SaCoS.Common.HW.ProductSpec,en; 04-2 SaCoS.HW.IM,E1,ProductSpec,en; 04-3 SaCoS5000.DML,2.x,GCM,2.x.HW,ProductSpec,Internal,EN; 04-4 SaCoS.HW.CM,E1,ProductSpec,en; 04-5 SaCoS5000.HW.CRM,,ProductSpec,internal,en; 04-6 SaCoS.5000.BSB.ProductSpec,en; 05-1,S5K,49-60DF,6-5-1-0,M,OI,EN,V3.0; 05-2,S5K,32-44CR,8-5-0-0,M,OI,EN,V1.1; 05-3,S5K,ERA,100-5.0.0,IMI,EN,V1.0;
Drawings: - 01-2,2,SaCoS,5000,Safety-Design,Overview-Sketch,Marine-Plant,Medium,Speed,,Large-Bore,V1.5.5, (2021-12-15),EN; 01-2,3,Safety,Stop,Design,S5K,ERA;,Medium,Speed,,Large,Bore,,Marine,Application,V1.0.3,
(2022-03-28),EN; 02-1 LMC,master,S5k,6,5.0.0-RC7.1,4960DF,2021-11-15; 02-2 LMC,master,S5k,6,5.0.0-RC7.1, 3244CR,2021-11-15; 2.5,Safety,Stop,Design;,S5K,Release,10-5.0.0;,High,Speed,,Marine,Application,V1.8.1,(2023-06-20),EN; 02-1 LMC,master,S5k,10,5.0.0-175D,2021-11-15; 03-1,SaCoS,5000,,Power,Supply,Overview, Large-Bore,Marine,V2.3.0,(2021-06-14); 03,02,MAN,175D,S5K,Power,Supply,Overview,V5.0.2,(2023-02-24); 06-10-32,44,Control,Unit,DRW,HW9103,5-1-2; 06-11-32,44,Driver,Cabinet,DRW,HW5165,5-1-2HF1; 06-12-32,44,Injection,Unit,DRW,HW9105,5-1-2; 06-13-32,44,Injection,Unit,Singel,Prop,DRW,HW9107,5-1-2HF1; 06-14-32,44,Interface,Cabinet,DRW,HW5080,5-0-0; 06-15-32,44,Local,Operating,Panel,DRW,HW9101,5-1-2; 06-16-32,44,Remote Operating Panel,DRW,HW9987,5-1-2; 06-17-32,44,Wheelhouse,Operating,Panel,DRW,HW9989,5-1-2; 06-18-32,44,Data,Logging,Cabinet,DRW,HW0146,3-0-0HF3; 06-19-ERA,Cabinet,HW5041,5-0-0; 06-20-49,60,Auxiliary Cabinet,DRW,HW5050,5-2-0; 06-21-49,60,Control,Unit,DRW,HW9103,5-1-2; 06-22-49,60,Driver,Cabinet,DRW,HW5165,5-2-0; 06-23-49,60,Gas,valve,Unit,Cabinet,DRW,KS5071A,5-1-1; 06-24-49,60,Injection,Unit,HW9105,5-1-2,IM1; 06-25-49,60,Injection,Unit,Single,Prop,HW9107,5-1-2HF1; 06-26-49,60,Interface,Cabinet,HW5035,5-2-0; 06-27-49,60,Remote,Operating,Panel,HW9987,5-1-2; 06-28-49,60,Wheelhouse,Operating,Panel,HW9989,5-1-2; 06-29-49,60,Combustion,Control,Unit,HW9108,5-1-2; 06-30-49,60,Knock,Control,Unit,HW9109,5-1-2; 06-31-49,60,Local,Operating,PanelHW9101,5-1-1; 06,1,4960DF,1133000-6-5.1.0.SaCoS5000,HWSysArchitecture,1.0.2; 06,2,4960DF,6-5.2.0.SaCoS5000,HWSysArchitecture,1.0.2; 06,3,SaCoS,EEA,HW-System-Architecture,Rel.X.x.x,v.0.0.3; 06,4,3244CR.SaCoS5000,HWSysArchitecture,1.0.4; 06,5,175d,HWSysArchitecture,175D,10-5.0.0; 06-32-HW5182,5-1-0,CU (2); 06-33-HW5189,5-0-0,EC; 06-34-HW5184,5-0-0,ROP; 06-35-HW5186,5-0-0,WOP; 06-36-HW5183,5-0-1,LOP; 06,05,175D,10-5.0.0,SaCoS5000,HWSysArchitecture,1.0.4; 06-12-32,44,Injection,Unit,DRW,HW9105,5-1-2; 06-15-32,44,Local,Operating,Panel,DRW,HW9101,5-1-2; 06-18-32,44,Data,Logging,Cabinet,DRW,HW0146,3-0-0HF3; 06-20-49,60,Auxiliary Cabinet,DRW,HW5050,5-2-0; 06-21-49,60,Control,Unit,DRW,HW9103,5-1-2; 06-23-49,60,Gas,valve,Unit,Cabinet,DRW,KS5071A,5-1-1; 06-24-49,60,Injection,Unit,HW9105,5-1-2,IM1; 06-26-49,60,Interface,Cabinet,HW5035,5-2-0; 06-29-49,60,Combustion,Control,Unit,HW9108,5-1-2; 06-30-49,60,Knock,Control,Unit,HW9109,5-1-2; 06-32-HW5182,5-1-0,CU (2); 06-33-HW5189,5-0-0,EC;
Software: - 07-02 Software,Versioning,Version1.8; 07-1 Basic-design-principles,application-software,SaCoS,5000; 07-3 EEDSB.MAN,SaCoS.SW,DDS,EN; 07-4 DDS,Firmware,Build,Projects; 07-5 SaCoS,5000,CoDeSys,Library,Documentation,,Framework,Basic,LIB,ALM; 07-6 SaCoS,5000,CoDeSys,Library,Documentation,,Framework,Basic,LIB,OPV; 07-7 SaCoS,Function overviews,Customer-Licensees,EN; 07-8 S5k,8-5.0.0,Integration,Component,Distribution,List; x 07-9 SaCoS 5000 Product Structur Version List;
FMEA: - 08-01-FMEA S5K LB M V1,0 en Upd02; 08-02-FMEA ERA LB M V1,0 en Upd00;

Test reports:
Protocols: - 09-2 Integrationstest SaCoS5000 Denamark_Class Approval 091023; 2023-02-06_Signed Type Approval Test - SaCoS 5000 System; 2023-03-21_49_60_l-SafetyIntegrationTest_signed-ocr

Remarks:
- Approval valid for ships intended to be granted with the following additional class notations: AUT-UMS, AUT-CCS and AUT-PORT.
- The system is suitable as a crankcase monitoring device in connection with monitoring of main bearings.
- Documents relating to each application are to be submitted to the Society's examination prior fitting on board.
- All changes in software and hardware are to be recorded as long as the system is in use on board.
- The records of all changes are to be forwarded to RINA for evaluation and approval.
- Major changes in the software / firmware are to be approved before being installed on the programmed systems.

Hamburg March 13, 2024
**** NOTICE: This is NOT an official certificate ****