The Self-contained compressed-air-operated breathing apparatus were designed in two different version with the following main characteristics:
Module | Max
Working
Pressure | Volume | Air Deposit | Using Time | Weight (Kg) | Packing Size (mm) | Working Temperature Range |
RHZK6 | 30 Mpa | 6 L | 1800 L | ≥60 min | ≤ 18 | 750 x 300 x 500 | -30 °C to 60 °C |
RHZK6.8 | 30 Mpa | 6.8 L | 2040 L | ≥60 min | ≤ 18 | 750 x 300 x 500 | -30 °C to 60 °C |
The main components list are as following:
Main Components List
Components | Model | Manufacturer |
Pressure Cylinder | 6 L or 6.8 L | Nanjing Banqiao Fire Equipment Co.,Ltd (6 L),
or Zhejiang Kaibo Pressure Vessel Co., Ltd (6.8 L) |
Air Cylinder Valve | KHF-30 | Taizhou Xiangqing Safeguard Equipment Co., Ltd |
Pressure Reducer | -- | assembled by Jiangsu Haituo Technology Co.,Ltd |
Air Supply Valve Assembly | -- | assembled by Jiangsu Haituo Technology Co.,Ltd |
Full-face Mask | -- | assembled by Jiangsu Haituo Technology Co.,Ltd |
Electrical Pressure Gauge and Rest Air Warning System, or
Mechanical Pressure Gauge and Rest Air Warning System | -- | assembled by Jiangsu Haituo Technology Co.,Ltd |
Back Frame and Harness | -- | assembled by Jiangsu Haituo Technology Co.,Ltd |
SCBA Box | -- | Jiangsu Haituo Technology Co.,Ltd |
 | ATTACHMENT TO
CERTIFICATE No. MED331226WS/001
Page 2 of 4 |
Continued:
Breathing Resistance at low temperatures:
The exhalation resistance of all types of apparatus shall not exceed 1.0 kPa.
Breathing Resistance at high temperatures:
The exhalation resistance shall not exceed 1.0 kPa.
Breathing Resistance (Inhalation resistance, Exhalation resistance) has been tested according to EN 13274-3, method 2 (settings E and H shall be used).
Field of Application
Self-contained compressed-air-operated breathing apparatus for shipboard use for fire-fighters.
Reference Documents
Technical Drawing of SCBA, approved by RINA with No.: SHFP-17921;
Material List of SCBA, approved by RINA with No.: SHFP-8749;
User Instruction and Maintenance Manual of SCBA , approved by RINA with No.: SHFP-18298;
Technical Data of SCBA, approved by RINA with No.: SHFP-18297;
Fireproof Lifeline Certificate (NTNHS) (Ref. No.: MED035818WS/012), filed by RINA with No.: SHFP-18296;
Gas Cylinder Certificate (6L) (Ref No.:Z-IS-DDG-MUC-12-08-790008-013-052), filed by RINA with No.: SHFP-8851;
Gas Cylinder Certificate (6.8L) (Ref No.: 03487/3/2012), filed by RINA with No.: SHFP-8852;
Tests Carried Out
Test Report (RHZK6, Ref No.:2018107) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances according to ISO 23269-2:2011 and filed by RINA with No.: SHFP-17917;
Test Report (RHZK6.8, Ref No.:2018108) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances according to ISO 23269-2:2011 and filed by RINA with No.: SHFP-17919;
Test Report (RHZK6.0/RHZK6.8, Ref No.: 2018107 ANNEX) issued by China Classification Society Wuhan Rules and Research Institute Testing Center of Marine Life-Saving Appliances according to ISO 23269-2:2011 & ISO 23269-3:2011 and filed by RINA with No.: SHFP-17918, attached with the Chemical Test Report (Test 4 &5) carried out by The Measure and Test Center of Shanxi Xinhua Chemical Limited Liability Company according to ISO 23269-2:2011 & ISO 23269-3:2011 and filed by RINA with No.: SHFP-18245;
Factory Inspection Report dated on 2026.06.16, and filled with RINA No. SHFP-37999.
 | ATTACHMENT TO
CERTIFICATE No. MED331226WS/001
Page 3 of 4 |
Continued:Remarks
Both types of SCBA have been designed in compliance with MSC.338(91) and MSC.339(91). And each type of SCBA can be provided with long-distance communication call device (made by Jiangsu Haituo Technology Co., Ltd), if requested by purchaser.
The SCBA can be equipped with different EC approved type Gas Cylinder of same capacity and Fireproof Lifeline in compliance with Directive 2014/90/EU as amended.
The breathing air shall comply with the requirements of EN 132. Each SCBA shall be marked according to
ISO 23269-2:2011(E), Para.9. The markings shall be as required by the specified standards and shall also include
the EC “Mark of Conformity" according to the Directive. The compressed air cylinder markings shall include the
charging pressure, capacity and the stamp of the authorized inspection body.
Additional information shall be supplied by the manufacturer according to EN 137:(2006), Par.9 after delivery. A set of manufacturer’s instructions shall accompany every unit and should be kept onboard. Manufacturer’s instructions for application / limitations, checks prior to use, donning and fitting, use, cleaning and disinfection, maintenance and storage shall be adhered to. Use and maintenance only by trained and qualified persons.
Use and maintenance only by trained and qualified persons.
Notes
Renewal of Previous EC Type Examination (Module B) Certificate No.:MED110121WS/001 dated June 22, 2021.
As declared, the initial conditions at the time of the approval are maintained.