SYMAP Products:
Digital protections relay and bay control units for generators, motors, transformers and power lines.
System voltage supply: 100 - 450 V AC
System current: 5 A
System aux. voltage supply: 24 V DC, 60 V AC/DC, 230 C AC/DC
SYMAP BC/BCG series
| Model | Function |
| CMA 190 | Controller PCB |
| CMA 191 | I/O Controller |
| CMA 192 | LED Controller |
| CMA 193 | Combi sensor module |
| CMA 195 | Power supply module |
| CMA 199 - xx | Analogue measuring input for protection functions |
SYMAP X/XG series
| Model | Function |
| CMA 200 | Controller PCB |
| CMA 201 | I/O Controller |
| CMA 202 - xx | Measuring transducer PCB |
SYMAP Y series (EC/ ECG/ F/ G/ LD/ M/ T)
| Model | Function |
| CMA 202 | Measuring transducer PCB |
| CMA 240 | Controller PCB |
| CMA 241 | I/O Controller |
| CMA 243 - xx | Power Supply, communication I/O |
| CMA 244 | Recording unit |
| CMA 245 | Voltage adaptation for binary input |
| CMA 246 | Voltage adaptation for additional binary inputs |
Common SYMAP modules
| Model | Function |
| CMA 194 | Fiber optic module, Profibus interface |
| CMA 198 | Independent short circuit detection |
| CMA 210 | Input module for 16 Pt100 sensors |
| CMA 211 | I/O module: digital 24 in/ 24 out and 16 Pt100 |
| CMA 212 | I/O module: digital 16 in/ 18 out |
| CMA 216 | extended board |
| CMA 217 | extended board: 6 Pt100, add on for CMA 216 |
| CMA 220 | AC/DC or DC/DC supply module (extension board) |
| CMA 221 | DC/DC supply |
TYPE APPROVAL CERTIFICATE
No. ELE248326XG
Enclosure - Page 2 of 2
SYMAP® BC / X / Y
The following functionality may be provided as defined by x the ANSI codes:
| 2 | Time relay starting or closing | 59 | Over voltage, instantaneous, def. time, IDMT |
| 12 | Overspeed | 64/59N | Ground over voltage/ residual over voltage |
| 14 | Underspeed | 66 | Number of starts |
| 15 | Matching | 67 | AC direction overcurrent, def. time |
| 24 | Over excitation protection | 67GS/GD | AC directional earth fault, def. time |
| 25/A | Automatic synchronizing | 78 | Vector surge supervision |
| 27 | Under voltage, instantaneous, definite time | 78S | Out of step tripping |
| 27B | Under voltage, def. time (bus 1 only) | 79 | Auto reclosing |
| 32 | Overload | 81 | Frequency supervision |
| 37 | Undercurrent | 81B | Bus frequency supervision |
| 46 | Reverse phase or phase balance current | 86 | Electrical lock out |
| 47 | Phase sequence voltage | 87LD | Line differential |
| 49 | Thermal overload protection | 87M | Motor differential |
| 50 | Overcurrent, instantaneous | 87T | Transformer differential |
| 50BF | Circuit-breaker failure | 87G | Generator differential |
| 50G/N | Current earth fault, instantaneous | 87N | Restrict earth fault |
| 51 | Overcurrent, def. time IDMT (6 curves) | 94 | Trip circuit supervision |
| 51G/N | Current earth fault, def. time, IDMT (6 curves) | 95i | Inrush blocking |
| 51 LR | Locked rotor | FF | Fuse failure |
| 51 VR | Voltage restrained overcurrent |
|
|
Software release:
- Control unit: 1.10
- Measuring unit: 1.10
- Recording unit: 1.10
Test reports:
Phoenix Test-Lab report. n.: S30097 (06/11/2003), E30097B (05/06/2003)
KERI report n. 02S1458 (05/12/2002)
Stucke Software function report n. GL_CMA190-200_0304031H (29/04/03)
General:
Data sheet: SYMAP Advance Digital Protection Relays
Remarks:
Installation on board of the above listed devices is subject to previous approval of the block diagram including a description of relevant functionalities.
The verification of the accuracy of protective triggering values is not part of this Certificate.
Depending on the specific application, independent protection may be required.