ELE340626XT!006ENG- -  -  N- MGH 0.6/1 kV -N- S- S- -13/10/2026- Prodotti Elettrici- - SN- N- - N-  - 369,823BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE340626XT/006- N-Oct 14, 2031369823
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE340626XT/006 - (ENG)
Certificate date 13/10/2026
Type Impianti Elettrici
Product CAVI ELETTRICI

Model or Denomin.
Items
MGH 0.6/1 kV
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Place of requester MAKINE O.S.B. 6.CADDE, NO.4 DILOVASI  %  41455 KOCAELI  % TURKEY
Tel. N.,Fax, Email +90 262 722 9330, +90 262 722 9443, erdogan.malkoc@untel.com.tr
Standards DIN 89160, IEC 60092-350
Expire date 14/10/2031
Head Office ISTANBUL
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE340626XT/006
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description ELECTRIC CABLES
Type MGH 0.6/1 kV
Applicant UNTEL KABLOLARI SANAYI VE TICARET A.S.
Reference standards DIN 89160, IEC 60092-350
  

 
 
   .   This Certificate is valid until October 14, 2031
_________________________________
RINA Services S.p.A.
Oytun Uzun
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE340626XT/006
Enclosure - Page 1 of 1
MGH 0.6/1 kV
Materials/Components

Shipboard power cables, flame retardant, halogen free with low smoke emission, for ships and off-shore units installation.

Rated voltage: 0.6/1 kV

Type: MGH

Marking: UNTEL DIN 89160 IEC 60092-353 MGH n x s mm2 0.6/1 kV IEC 60332/3A


Construction:
conductor: stranded copper wire class 2 or 5, tinned on request

insulation: HF-EPR
bedding: halogen free compound
sheath: SHF1

Max. conductor temperature: 90°C.

In accordance to rules DIN 89160; IEC 60228 ; IEC 60092-350; IEC 60092-353; IEC 60092-360; IEC 60332-1-2; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034-1; IEC 61034-2.


Conductor size:

number of cores 1 - cross sectional area from 1.5 to 300 mm2
number of cores 2, 3, 4 - cross sectional area from 1 to 300 mm2
number of cores 5 - cross sectional area from 1 to 240 mm2
number of cores 7 - cross sectional area from 1 to 4 mm2
number of cores 10,12,14,16, 18, 19, 20, 21, 24, 25, 27, 30, 32, 34, 36, 37 - cross sectional
area from 1 to 2.5 mm2

Technical specification: data sheet N. FR 70-040 Rev1 dated 01/07/2011.



ISTANBUL 14/10/2026
**** NOTICE: This is NOT an official certificate ****