1. Product Description:
The S-Drive Converter Controlled Cabinet is mainly used to variable frequency electronic control, it adopts highly standardized electrical and structural designs, combined with a highly customizable control system. It simultaneously supports multiple solutions such as S-DE, S-Shaft, and S-Renewable. Electronic components and PLC modules other than the touch screen are installed inside the cabinet, and the touch screen can be installed on the cabinet or on other control consoles on board.
+ Power supplies: AC220V & DC24V
+ Main components and approval range as follow:
Item | Vendor | Product model | Firmware version | Application software and version |
Maser PLC | B&R | X20CP series; APC910 | N/A | Automation Studio, V4.9.4.92 SP |
Sub LC | B&R | X20CP series; APC910 | N/A | Automation Studio, V4.9.4.92 SP |
I/O module | B&R | X20 series I/O module | N/A | N/A |
Industrtrial Secure Router | Moxa | EDR-8010 series | N/A | EDR-8010, V3.19 |
Switch | Moxa | EDS-405A/EDS-40A series | N/A | EDS-405A/DS-408A, V3.14 |
HUB | B&R | 0AC808.9-1 | N/A | N/A |
HMI | Beijer | X2 eries | N/A | iX Developer,sp7 2.47.473 |
S-Link | SETH | S-Link-C | S-Link-Firmware, Ubuntu20.04-20240313 | HUGINN, 1.0 |
Converter power mdule | SETH | LM series | N/A | N/A |
ABB | ACS880 series | N/A | N/A |
Danfoss | NXA/NXP/NXB series | N/A | N/A |
2. Testing:
+ Integration tests for the subjected products have been conducted in a simulation environment in accordance with the requirements of
IACS UR E27, IEC 62443-3-3 SL1, and RINA Rules. The tests were carried out by CNAS laboratory or witnessed by a RINA Surveyor
and included the following items:
Item | Test standards IEC 62443-3-3 | Item | Test standards IEC 62443-3-3 |
1 | SR 1.1 – Human user identification and
authentication | 16 | SR 2.11 – Timestamps |
2 | SR 1.3 – Account management | 17 | SR 3.1 – Communication integrity |
3 | SR 1.4 – Identifier management | 18 | SR 3.2 – Malicious code protection |
4 | SR 1.5 – Authenticator management | 19 | SR 3.3 – Security functionality verification |
5 | SR 1.6 – Wireless access management(Not
applicable) | 20 | SR 3.6 – Deterministic output |
6 | SR 1.7 – Strength of password-based
authentication | 21 | SR 4.1 – Information confidentiality |
7 | SR 1.10 – Authenticator feedback | 22 | SR 4.3 – Use of cryptography |
8 | SR 2.1 – Authorization enforcement | 23 | SR 6.1 – Audit log accessibility |
9 | SR 2.2 – Wireless use control (Not applicable) | 24 | SR 7.1 – Denial of service protection |
10 | SR 2.3 – Use control for portable and mobile
devices | 25 | SR 7.2 – Resource management |
11 | SR 2.4 – Mobile code | 26 | SR 7.3 – System backup |
12 | SR 2.5 – Session lock | 27 | SR 7.4 – System recovery and reconstruction |
13 | SR 2.8 – Auditable events | 28 | SR 7.5 – Alternative power source |
14 | SR 2.9 – Audit storage capacity | 29 | SR 7.6 – Network and security configuration
settings |
15 | SR 2.10 – Response to audit processing
failures | 30 | SR 7.7 – Least Functionality |
TYPE APPROVAL CERTIFICATE |
No. ELE188526WS |
Enclosure - Page 2 of 2 |
S-Drive Converter Controlled Cabinet |
+ Additional security capabilities tests for the subjected products have been conducted in a simulation environment in accordance with the requirements of IACS UR E27, IEC 62443-3-3 SL1, and RINA Rules. The tests were carried out by CNAS laboratory or witnessed by a RINA Surveyor and included the following items:
Item | Test standards IEC 62443-3-3 | Item | Test standards IEC 62443-3-3 |
31 | SR 1.1 RE 2– Multifactor authentication for human users (Not applicable) | 37 | SR 2.6 – Remote session termination (Not applicable) |
32 | SR 1.2 – Software process and device identification and authentification | 38 | SR 3.1, RE1 – Cryptographic integrity protection (Not applicable) |
33 | SR 1.11 – Unsuccessful login attempts (Not applicable) | 39 | SR 3.5 – Input validation (Not applicable) |
34 | SR 1.12 – System use notification (Not applicable) | 40 | SR 3.8 – Session integrity (Not applicable) |
35 | SR 1.13 – Access via Untrusted Networks | 41 | SR 3.8, RE1 – Invalidation of session IDs after session termination (Not applicable) |
36 | SR 1.13, RE1 – Explicit access request approval |
| |
3. Reference Documents:
+ System asset inventory. Filed by RINA with drawing No. SHEL-31072.
+ System topology diagram. Filed by RINA with drawing No. SHEL-31079.
+ Description of system security capabilities. Filed by RINA with drawing No. SHEL-31080.
+ Test procedure of security Capabilities. Filed by RINA with drawing No. SHEL-31081.
+ Guidelines for hardening and configuration of security capabilities. Filed by RINA with drawing No. SHEL-31082.
+ Secure development lifecycle documents. Filed by RINA with drawing No. SHEL-c31083.
+ Plans for maintenance and verification. Filed by RINA with drawing No. SHEL -31084.
+ Information supporting incident response and recovery plans. Filed by RINA with drawing No. SHEL-31086.
+ Management of change plan. Filed by RINA with drawing No. SHEL-31087.
+ Test Report of a CNAS laboratory. Filed by RINA with drawing No. SHEL31073.
+ Test Report witnessed and signed by our attending Surveyor. Filed by RINA with drawing No. SHEL-31073.
4. Note/Remark:
+ The validity of this Certificate is subject to maintenance of the initial product conditions verified by RINA Services. Changes to the initial
conditions must be communicated to RINA Services which reserves the right to carry out further verification activity to confirm the
validity of this Certificate.
+ The rules, surveys and activities performed by RINA, reports, certificates and other documents issued by RINA are in no way intended to
replace the duties and responsibilities of other parties such as Governments, designers, ship builders, manufacturers, repairers, suppliers,
contractors or sub-contractors, owners, operators, charterers, underwriters, sellers or intended buyers of a ship or other product or system
surveyed. |
|