1. Product Description
The Energy Management System (CAEV-EMS01-2P) is an essential component of the DC integrated power system. This
energy management system is suitable for electric vessels powered solely by batteries or hybrid energy sources. It is designed to monitor and optimize energy flow and consumption within the power system, ensuring stable operation of the power station. Additionally, it can receive propulsion control commands from the bridge or other control stations to manage propeller start/stop, speed/power adjustment, and other functions.
+ Power supplies : AC 220V, 60Hz & DC 24V
+ Main Components and approval range:
EMS main components list |
Item | Function | Device type | Brand |
1 | CPU | X20CP0484 | B&R |
2 | Digital input | X20DIF371 | B&R |
3 | Digital output | X20DOF322 | B&R |
4 | Analog input | X20AI4622 | B&R |
5 | Analog input(PT100/1000) | X20AT4222 | B&R |
6 | Analog output | X20AO4622 | B&R |
7 | 10' inch touch panel | 4PPC50.101E-13A | B&R |
8 | 1 channel CAN | X20CS1070 | B&R |
9 | CPU power module | X20PS9600 | B&R |
10 | CPU bus base | X20BB67 | B&R |
11 | Bus module | X20BM11 | B&R |
1 | Terminal block | X20TB12 | B&R |
13 | Terminal block | X20TB1F | B&R |
14 | Serial module | X20CS1030 | B&R |
15 | profinet | X20IF10E1-1 | B&R |
16 | Breaker | S202-C6 | ABB |
17 | Switch power | QUINT-PS/1AC/24DC/10 | Phoneix |
18 | Switch power | QUINT-PS/24DC/24DC/10 | Phoneix |
19 | Redundancy power | QUINT-ORING/24DC/2*10/1*20 | Phoneix |
20 | Management Switch | FL SWITCH 2206-2FX | Phoneix |
21 | Fuse | PTTB 4-HESILED 24 (5X20) | Phoneix |
22 | Terminal | PTTBV 2,5 | Phoneix |
23 | Relay | PLC-RPT- 24DC/21 | Phoneix |
24 | Ground terminal | PT 1,5/S/1P-PE | Phoneix |
25 | indicator light | AD16-22D/R23S | APT |
26 | buzzer | AD16-22M/r31 | APT |
27 | button | PB1S-11/w | APT |
Type approval certificate
No. ELE781226WS
Enclosure - Page 2 of 2
CAEV-EMS01-2P
2. Reference Documents
+ EMS technical documentation, Filed by RINA with drawings No.: SHEL-27392 to SHEL-37402.
+ Test Report test by authorized laboratory. Filed by RINA with drawing No. SHEL-27557 and SHL-27558.
+ Routine test Report and narrative report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-30525 and SHEL-30526.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-27555.
3. Note/Remark
+ For each configuration, the following documentation is to be submitted for approval:
- System description / scope of supply
- System block diagram
- Functional description
- External connection block diagram
- Power supply block diagram
- Factory Acceptance Test Procedure
+ Traceability of Hardware and Software is to be ensured for each installation and evidence is to be available on request.
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment.