1. Product Description
150/250V shipboard control cables having following rating:
Type Designation | Number of Cores | Nominal Conductor
Cross-sectional Area [mm²] | Maximum rated
Conductor Temperature[℃] | Fire Property |
CKJ85/86
CKJP85/86
CKJPJ85/95
CKJPF86/96
CKJPJP85/95
CKJPFP86/96
/(SC/NSC) | 2~37 | 0.75~2.5 | 90 | Flame-retardant
-IEC 60332-1-2
-IEC 60332-3-22
Fire-resisting
- IEC 60331-1
- IEC 60331-2 |
Note: + “Number of Cores” is selected from the following series of core number:
2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 30, 33, 37.
+ “Nominal Conductor Cross-sectional Area” is selected from the following series of core number:
0.75, 1.0, 1.5, 2.5 mm2.
+ Conductor: Tinned copper conductors
+ Other properties’ suffix:
CK: Shipboard control cable
J : XLPE
P : Cores or twisted pairs with individually screen
PJ: Cross-linked polyolefin (SHF2)
PF: Polyolefin (SHF1)
85: Copper or Tinned copper wire braid ,cross-linked polyolefin outer sheath (SHF2)
95: Galvanized steel wire braid, cross-linked polyolefin outer sheath (SHF2)
86: Copper or Tinned copper wire braid, polyolefin outer sheath (SHF1)
96: Galvanized steel wire braid, polyolefin outer sheath (SHF1)
SC: Single cable flame retardant, Bunched cable flame retardant, Low-smoke, Halogen-free and Low-toxicity
NSC: Fire resistance, Single cable flame retardant, Bunched cable flame retardant, Low-smoke, Halogen-free and Low-toxicity
 | ATTACHMENT TO
CERTIFICATE No. MED893825WS/001
Page 2 of 3 |
2. Application
The control and instrumentation cables are approved used for fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, cabin balconies, machinery spaces and unattended machinery spaces in marine and offshore field.
3. Design Assessment
The design assessment is based on SOLAS 74 Reg. II-2/7, IMO Res. MSC.36(63)-(1994 HSC Code) 7, IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO Res. MSC.98(73)-(FSS Code) 9, IMO Res. MSC.391(95)-(IGF Code) 11, IMO MSC.1/Circ.1242.
Cable installation in ships, as applicable, comply with IEC standards: IEC 60092-504:2016, IEC 60533:2015, IEC 60332-1-2:2004 incl.A1:2015, IEC 60092-376:2017, IEC 60331-1:2018 or IEC 60331-2:2018.
4. Tests Carried Out
Test reports: “China National Centre for Quality Supervision and Test of Electric Wire and Cable”. Report No.: CT07-1214-12, CT07-1214-13 and CT07-2053-2, according to IEC 60092-350:2020; IEC 60092-360:2021, IEC 60092-376:2017; IEC 60331-1:2018, IEC 60331-2: 2018, IEC 60332-1-2:2004 incl.A1:2015, IEC 60332-3-22:2018. Filed by RINA with drawing No.: SHEL-28877.
Routine test Report witnessed and signed by RINA Surveyor. Filed by RINA with drawing No.: SHEL-28878.
5. Reference Documents
Technical drawings and manuals approved and filed by RINA listed on Approval letter No.: SHEL/2026/313/SD019 and No.: SHEL/2026/341/SD019. |