MED274525WS!001ENG- -  -  N- GTYQ-WRS81,GTYQ-WRS91,GQ-WRS81,GQ-WRS91 -N- S- S- -03/04/2026- Marine Equipment- - SN- S- - N-  - 2,343,060B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED274525WS/001- N-Apr 2, 20312343060
 
Form
  Marine Equipment(TO)
Certification N. MED274525WS/001 - (ENG)
Certificate date 03/04/2026
Type Protezione antincendio
Product Fixed oxygen analysis and gas detection equipment: (b) category 3 - explosive gas atmospheres
Item Nº MED/3.54b

Model or Denomin.
Items
GTYQ-WRS81,GTYQ-WRS91,GQ-WRS81,GQ-WRS91
Applicant WAROM TECHNOLOGY INCORPORATED COMPANY
Place of requester No.555, Baoqian Road, Jiading District, Shanghai (Shanghai)  % CHINA
Tel. N.,Fax, Email 19521327009, ---,cgyf@warom.com
Directive (EU) 2025/1533
Standards EN 50104:2019 incl. EN 50104:2019/A1:2023, EN IEC 60079-0:2018 incl. AC:2020-02, AND A11:2024, EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/a11:2022, IEC 60092-504:2016, IEC 60533:2015, For combined O2/HC systems, additionally: IMO MSC.1/Circ. 1370.
Reference Documents SOLAS Reg. II-2/4, SOLAS Reg. VI/3, IMO Res. MSC.98(73)-(FSS Code) 15. For combined O2/HC systems additionally: IMO MSC.1/Circ.1370.
Expire date 02/04/2031
Responsible Office SHANGHAI
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Zhi Yuan Tan S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED274525WS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.54b
Description Fixed oxygen analysis and gas detection equipment: (b) category 3 - explosive gas atmospheres
Type GTYQ-WRS81,GTYQ-WRS91,GQ-WRS81,GQ-WRS91
Applicant WAROM TECHNOLOGY INCORPORATED COMPANY
No.555, Baoqian Road, Jiading District, Shanghai (Shanghai),CHINA
Testing standards EN 50104:2019 incl. EN 50104:2019/A1:2023, EN IEC 60079-0:2018 incl. AC:2020-02, AND A11:2024, EN 60079-29-1:2016 incl. EN 60079-29-1:2016/A1:2022 and EN 60079-29-1:2016/a11:2022, IEC 60092-504:2016, IEC 60533:2015, For combined O2/HC systems, additionally: IMO MSC.1/Circ. 1370.
Reference standards SOLAS Reg. II-2/4, SOLAS Reg. VI/3, IMO Res. MSC.98(73)-(FSS Code) 15. For combined O2/HC systems additionally: IMO MSC.1/Circ.1370.
Issued in SHANGHAI on
This Certificate is valid until
April 3, 2026
April 2, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Zhi Yuan Tan
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED274525WS/001
Page 1 of 3
1. Product Description

Product contains the following types:

Model
GTYQ-WRS81
GTYQ-WRS91
GQ-WRS81
GQ-WRS91
Detection principle
Catalytic combustion type/Point-type infrared
Catalytic combustion type/Point-type infrared
Electrochemical
Electrochemical
Gas to be detected
Combustible gas
Combustible gas
O2
O2
Detection range
(3-100)%LEL
(3-100)%LEL
(0-25)%VOL
(0-25)%VOL
Power supply voltage
AC85V~AC265V、24VDC、12VDC、3.7VDC
Explosion protection
Ex db IIC T6 Gb; Ex tb IIIC T80℃ Db
Ingress Protection
IP65 / IP66
Operating temperature
-40°C ~ +55°C/-40°C~+70°C

This certificate covers models GTYQ-WRS81/82 and GQ-WRS91/92, with details available in the product model definition.













 



ATTACHMENT TO
CERTIFICATE No. MED274525WS/001
Page 2 of 3


2. Application/Limitation

Ex certification is not covered by this certificate, Applications in hazardous areas are to be approved in each case according to the Rules and Conditions for Safe Use specified in a valid Ex-Certificate issued by a Notified or Recognized Certification Body.

3. Design Assessment

The design assessment is based on SOLAS Reg. II-2/4, SOLAS Reg. VI/3, IMO Res. MSC.98(73)-(FSS Code)15. For combined O2/HC systems additionally: IMO MSC.1/Circ.1370.

4. Tests Carried Out

The test report, including environment test, EMC test and performance test, complies with EN 50104:2019, EN IEC 60079-0:2018 incl. AC:2020, EN 60079-29-1:2016, IEC 60092-504:2016, and IEC 60533:2015. For combined O2/HC systems,additionally: IMO MSC.1/Circ. 1370. Tests were conducted in authorized laboratory and comply with these standards. Reports are filed by RINA with drawing No.: SHEL-28794.



Inspection report (Date on 2025, July 25) edit by "WAROM TECHNOLOGY INCORPORATED COMPANY" and witnessed by RINA Surveyor. Filed by RINA with drawing No.:SHEL-29130.

5. Reference Documents
Analysis and assessment of risk, Filed by RINA with drawing No. SHEL-28799.
European Representative Authorization Letter. Filed by RINA with drawing No.SHEL-28797.
Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-28800.

Technical drawings and manuals approved and filed by RINA listed on Approval letter No.: SHEL/2026/297/JY001 and SHEL/2026/345/JY001.

6. Marking of Product

The product is to be indelibly marked with name and address of the manufacturer, type designation, batch or serial number or other elements allowing their identification and the MED Mark of Conformity.





ATTACHMENT TO
CERTIFICATE No. MED274525WS/001
Pages 3 of 3
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Zhi Yuan Tan
**** NOTICE: This is NOT an official certificate ****