Form
  Marine Equipment(TO)
Certification N. MED193926PU - (ENG)
Certificate date 13/09/2026
Type Prevenzione dell'inquinamento marino
Product Inceneritori di bordo
Item Nº MED/2.7

Model or Denomin.
Items
MAXI T50SL WS, T100SL WS, T150SL WS
Applicant HYUNDAI MARINE MACHINERY CO., LTD.
Place of requester 154-63 Gimhae-daero 916beon-gil, Hallim-myeon,  %  50850 Gimhae-Si (Gyeongsangnam-do)  % REPUBLIC OF KOREA
Tel. N.,Fax, Email +82 55 670 9060, +82 55 633 7937, qa@hmmco.co.kr
Directive (EU) 2026/1434
Standards IMO Res. MEPC.244(66),IMO Res. MEPC.368(79)
Reference Documents Annex VI, Regulation 16 of Marpol 73 / 78 as amended
Expire date 31/03/2031
Head Office RINA Korea Marine
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Jin Young Kim S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED193926PU

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Marine-Pollution prevention requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2026/1434.
MED Item Nº MED/2.7
Description Shipboard incinerators
Type MAXI T50SL WS, T100SL WS, T150SL WS
Applicant HYUNDAI MARINE MACHINERY CO., LTD.
154-63 Gimhae-daero 916beon-gil,Hallim-myeon,50850 Gimhae-Si (Gyeongsangnam-do),REPUBLIC OF KOREA
Testing standards IMO Res. MEPC.244(66),IMO Res. MEPC.368(79)
Reference standards Annex VI, Regulation 16 of Marpol 73 / 78 as amended
Issued in RINA Korea Marine on
This Certificate is valid until
September 14, 2026
March 31, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Jin Young Kim
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED193926PU
Page 1 of 9

Product Description


The MAXI T Series are intended for installation onboard ships and other marine installation for the incineration of oil residue (sludge) or solid waste. The system also enables solid waste to be added to the incinerator when operating in oil residue (sludge) mode after the incinerator has warmed up. The solid waste is then burned with the assistance from the oil residue (sludge) burner when the heat from burning solid waste is insufficient. There is an additional mode where oil residue (sludge) and bilge oil can be fed into the incinerator together. In this mode incineration begins with feeding of oil residue (sludge) until the incinerator has warmed up, then bilge oil feeding begins using a separate bilge injection burner. The feeding rate of the oil residue (sludge) and bilge oil is controlled based on temperature in the primary combustion chamber so that the maximum capacity is not exceed.

The incinerators consist of a primary combustion chamber, a secondary combustion chamber and an after-burning chamber for burning out uncombusted exhaust gases. The combustion chambers are equipped with diesel oil burners.

Solid waste is fed into the incinerator through a door system with interlocks. This enables the waste packages to be loaded through the outer door and fed into the incinerators through the inner door when the outer door is closed in cycles (i.e., continuous feeding).

Ash accumulates in the combustion chambers and may be removed from the incinerator periodically when the incinerator is cold through the ash door.

A flue gas fan is fitted in the exhaust duct or on the incinerator module to pull a negative pressure in the combustion chamber. Cooling air is pulled through a jacket around the incinerator from the compartment the incinerator is located.










ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 2 of 9
Application
Model(*)
T50SL WS
T100SL WS
T150SL WS
Type of solid waste loading
Continuous feed
Continuous feed
Continuous feed
Calorific capacity kW (kcal/h)
465 (400,000)
768 (660,000)
988 (850,000)
Solid waste (kg/h)
100
100
150
Oil residue (sludge) (kg/h)
47
77
99
Oil residue (sludge) (kg/h) with bilge water (l/h) (**)
60
159 bilge water
100
200 bilge water
128
228 bilge water
(*) Model code SL means equipped for burning Solid waste and Oil Residue (sludge) and WS means equipped with a sluice that can be continuously load.
(**) Oil Content in bilge water is 0%.

Electrical and control components

The units are controlled through automation systems of a type tested and accepted by a nationally recognized testing agency, according to international standards. Critical components are listed in the table below:

Component Type
Component Name and Model (**)
Maker
Programmable Logic Controller (PLC)
MICROLOGIX 1400 Series
Allen-Bradley

SIMATIC S7-1200 Series
Siemens
Human Machine Interface (HMI)
PV Plus 700 Series
Allen-Bradley

Pro-face GP4401 Series
Schneider Electric
Flame Detection Replay
HRE-4X
Hyundai Marine Machinery Co., Ltd.
Flame detector
Flame detection photocell QRB Series
Siemens AG
(** ) The system can be configured with either a Allen-Bradley PLC and HMI or a Siemens PLC and HMI.

Change to these components are to be approved by RINA. Documentation confirming the approval are to be kept together with the certificate, or the certificate is to be updated.

The software and firmware editions are listed in the table below:

Component
Software/Firmware Edition
Date
Allen-Bradley MICROLOGIX 1400 Series
Software : RS LOGIX 500V8.XX
Firmware : 1.X
2016
Siemens SIMATIC S7-1200
Software : TIA POTAL V13.XX
Firmware : 10.X
2016
Allen-Bradley PV Plus 700 Series (HMI)
Software : FT VIEW STUDIO V7.XX
Firmware : 10.X
2016
Schneider Electric Pro-face GP4401 Series (HMI)
Software : GP-Pro EX V4.XX
Firem 4.X
2016
Changes in the software which can alter the performance of the systems is to be approved by RINA. Note that testing of the system with the revised software may be required. Documentation confirming the approval (and any testing) are to be kept together with the certificate, or the certificate is to be updated.



ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 3 of 9

Basic of acceptance

Capacity and emissions testing according to IMO Res.MEPC.244(66) Annex I were carried out on the MAXI T50SL WS, MAXI T100SL AND MAXI T150SL WS models and the results are given in the Appendices to this certificate.

Electrical and mechanical control devices have been assessed according to IMO Res.MEPC.244(66) 3.14.1.7 based on certificate according to internal standards accepted by a national recognized testing agency. The control pannels for the MAXI T50SL WS, MAXI T100SL WS and MAXI T150SL WS models were each subjected to a function test in 2000 and the final test reports are listed in the "Test Reports" section of this certificate. The control system was changed from a relay type to a PLC type in 2008 and so a new function test on a MAXI T150SL WS was conducted. The test report is listed in the "Test Reports" section of this certificate. The MAXI T Series all use the same control system and so the test can be considered applicable to all models.

Inclination requirements according to IMO Res.MEPC.244(66) Section 6.2 were assessed during the testing of the MAXI T50SL WS, MAXI T100SL WS and MAXI T150SL WS models.

Prototype tests according to IMO Res.MEPC.244(66) Section 7.1 were carried out on the MAXI T150SL WS model and the final report is listed in the "Test Reports" section of this certificate. This test can be considered applicable to all models.

The series of incinerators with capacities from 465 kW to 989 kW use the same basic design. Therefore, testing presented in the Appendices is considered sufficient to cover all models

The testing described above for solid waste was done under the authority of Bureau Veritas who issued EU MED Module B certificate no. 09529/C2 EC. The testing described above for oil residue (sludge) for the other models was done under the authority of Korean Register on behalf of the Republic of Korea.





















ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 4 of 9
Technical Documentation
  • Technical drawings and Manual, filed by RINA approved drawing no.PUMC-27813, 27814& 27816 as outlined below.
  • Drawing no.
    Revision
    Date
    Description/name
    Model
    VHS-T050SL WS-1 ~ 3
    R0
    2016.04.12.
    Main specification
    MAXI T50SL WS
    VHS-T100SL WS-1 ~ 3
    R0
    2016.04.12.
    Main specification
    MAXI T100SL WS
    VHS-T150SL WS-1 ~ 3
    R0
    2016.04.12.
    Main specification
    MAXI T150SL WS
    VHS-LOCSA-STD-1
    R0
    2016.04.12.
    List of control /Safety / Automation
    All Model
    VHS-PROCEDIA-STD-1
    R0
    2016.04.12.
    Process diagram incinerator
    All Model
    HIE-P04020020
    R2
    2016.03.24.
    Piping diagram
    MAXI T50SL WS
    HID-T052003
    R2
    2016.03.24.
    Outline dimension drawing
    MAXI T50SL WS
    HID-BOD05203
    R7
    2013.04.30.
    Assembly drawing of Basis part
    MAXI T50SL WS
    HMW-WT052001 ~ 5
    R1
    2013.04.30.
    Assembly drawing of Refractory Lining
    MAXI T50SL WS
    HIE-WT102004
    R2
    2016.03.24.
    Piping diagram
    MAXI T100SL WS
    HID-T1000203
    R2
    2016.03.24.
    Outline dimension drawing
    MAXI T100SL WS
    HID-BOD100203
    R7
    2013.04.30.
    Assembly drawing of Basis part
    MAXI T100SL WS
    HMW-WT102001 ~ 5
    R1
    2013.04.30.
    Assembly drawing of Refractory Lining
    MAXI T100SL WS
    HIE-WT152004
    R2
    2016.03.24.
    Piping diagram
    MAXI T150SL WS
    HID-T152003
    R2
    2016.03.24.
    Outline dimension drawing
    MAXI T150SL WS
    HID-BOD15203
    R5
    2013.04.30.
    Assembly drawing of Basis part
    MAXI T150SL WS
    HMW-WT152001 ~ 5
    R1
    2013.04.30.
    Assembly drawing of Refractory Lining
    MAXI T150SL WS
    HID-VM1502210
    R0
    2013.04.30.
    Detail drawing of Cleaning cover
    All Model
    HID-S12002010
    R1
    2013.04.30.
    Assembly drawing of Waste sluice
    All Model
    AT-ABB0500
    R1
    2008.01.01
    Outline of primary blower
    MAXI T50SL WS
    AT-ABBT1500
    R1
    2008.01.01.
    Outline of primary blower
    MAXI T100SL WS
    AT-ABBT1500
    R1
    2008.01.01.
    Outline of primary blower
    MAXI T150SL WS
    HIF-NGTSTD002 ~ 4
    R2
    2016.03.24
    ELECTRIC PANEL-LAYOUT/FRONT
    All Model
    HIF-NGTSTD005 ~ 7
    R2
    2016.03.24
    ELECTRIC PANEL-LAYOUT/FRONT
    All Model
    HIF-NGTSTD008
    R2
    2016.03.24
    ELECTRIC PANEL-CONTROL SOURCE
    All Model
    HIF-NGTSTD015 ~ 24
    R2
    2016.03.24
    ELECTRIC PANEL-CIRCUIT DIAGRAM
    All Model
    HIF-NGTSTD025
    R2
    2016.03.24
    ELECTRIC PANEL-CIRCUIT OPTION
    All Model
    HIF-NGTSTD030
    R2
    2016.03.24
    ELECTRIC PANEL-EXTERNAL SIGNAL
    All Model
    HIF-NGTSTD040 ~ 43
    R2
    2016.03.24
    ELECTRIC PANEL-PART LIST
    All Model
    HIF-NGTSTD501 ~ 3
    R2
    2016.03.24
    ELECTRIC PANEL-TERMINAL STRIP
    All Model
    HNP-MAXINC-EPA7
    R7
    2011.11.26
    MAIN NAME PLATE
    All Model
    NP-SIMENS-OPAPLC-NGT
    R7
    2014.09.11
    OPERATION INSTRUCTION PLATE
    All Model
    NP-WNPLC
    R9
    2014.09.11
    WARNING PLATE
    All Model
    HINC-PGM-MAXIJAL
    R0
    2015.09.11
    PLC LADDER SYSTEM SOFTWARE QUALITY PLAN
    All Model
    V13-NGDO(PLC_SIMENS)
    R13
    2015.06.03
    INSTRUCTION MANUAL (NG25 ~ NG150)
    All Model
    V13-BIG(PLC_SIMENS)
    R13
    2015.06.03
    INSTRUCTION MANUAL (MAXI 1200, 1500)
    All Model
    V13-TDO(PLC_SIMENS)
    R13
    2015.06.03
    V13-TDO(PLC_SIMENS)
    All Model




ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 5 of 9

Capacity and Emission tests, and safety and control tests:
  • Type approval test procedure & report for waste oil incinerator, MAXI T100 SL WS, Hyundai Marine Machinery Co., Ltd., document no.MEDHS10-06, Type Test Report No.HTTR-1314, dated 26 May 2000. (Witnessed by Bureau Veritas)
  • Type approval test procedure & report for waste oil incinerator, MAXI T150 SL WS, Hyundai Marine Machinery Co., Ltd., document no.MEDHS10-06, Type Test Report No.HTTR-1259, dated 25 April 2000. (Witnessed by Bureau Veritas)
  • MAXI type W.O. incinerator test report, Hyundai Marine Machinery Co., Ltd., report No.HFTR-IMOT50, dated 3 November 2008. (Witnessed by Korean Register on behalf of the Republic of Korea.)
  • MAXI type W.O. incinerator test report, MAXI NG150SL WS, Hyundai Marine Machinery Co., Ltd., report HFTR-IMONG150 dated 13 Februray 2004. (Witnessed by Korean Register on behalf of the Republic of Korea.)
  • Test reports, filed by RINA approved drawing no.PUMC-27815.

Safety and control tests (prototype tests according to IMO Res.MEPC.244(66) Section 7.1):

  • Shipboard incinerator Final Test Report, Type MAXI T150SL WS (PLC Type), Hyundai Marine Machinery Co., Ltd., Test Report No.HTTR-S3617, dated 28 May 2008. (Witnessed by Bureau Veritas)


Marking of product

For traceability to this type approval, each incinerator is to be marked with:

  • Manufacturer's name or trade mark
  • Style, type, model or other manufacturer's designation for the incinerator (i.e., model name with serial number)
  • Capacity (net design heat release)


Note
  • This certificate annuls and replaces the certificate No. MED247225PU dated 01-04-2026 due to change of the applicant's
address.














ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 6 of 9
Appendix - Tests on MAXI T50SL WS

Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW

This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.



Test Data:
Incinerator manufactured by:
Hyundai Marine Machinery Co., Ltd.
Incinerator type and model
MAXI T50SL WS
Place and date of tests
Seoul, 3 November 2004. (Witnessed by Korean Register on behalf of the Republic of Korea)
Max. capacity
480 kW (with Oil Residue (sludge))
Oil Residue (sludge)
51.4 l/h
34,160 KJ/kg (25% water content)
Pilot Fuel Consumption (Oil Residue (sludge))
0 kg/h per burner

Combustion chamber and flue gas records:
Parameter / Type of Waste
Oil Residue (sludge)
O2 average in combustion chamber / zone
10.9 %
CO average in flue gas
21.2 mg/MJ
Soot number average
Bacharach 1
Combustion chamber flue gas outlet temperature average
899 °C
Amount of unburned components in ashes
0 %

Shock-cooling of Flue Gas:

Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:

Parameter
Oil Residue (sludge)
Temperature
321 °C
Distance
2.5 m

A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.







ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 7 of 9
Appendix - Tests on MAXI T100SL WS

Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW

This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.



Test Data:
Incinerator manufactured by:
Hyundai Marine Machinery Co., Ltd.
Incinerator type and model
MAXI T100SL WS
Place and date of tests
Seoul, 26 May 2000 (witnessed by Bureau Veritas)
Max. capacity
340 kW (with Solid Waste)
Solid Waste
103.5 kg/h IMO Class 2
11,776 KJ/kg
Pilot Fuel Consumption (Solid Waste)
14 kg/h per burner (2 burners)

Combustion chamber and flue gas records:
Parameter / Type of Waste
Solid Waste
O2 average in combustion chamber / zone
10.0 %
CO average in flue gas
96.0 mg/MJ
Soot number average
Bacharach 1
Combustion chamber flue gas outlet temperature average
950 °C
Amount of unburned components in ashes
9.0 %

Shock-cooling of Flue Gas:

Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:

Parameter
Solid Waste
Temperature
320 °C
Distance
2.5 m

A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.







ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 8 of 9
Appendix - Tests on MAXI T150SL WS

Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW

This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.

Test Data:

Incinerator manufactured by:
Hyundai Marine Machinery Co., Ltd.
Incinerator type and model
MAXI T150SL WS
Place and date of tests
Seoul, 25 April 2000 (witnessed by Bureau Veritas)
Max. capacity
509 kW (with Solid Waste)
Solid Waste
150 kg/h IMO Class 2
11,776 KJ/kg
Pilot Fuel Consumption (Solid Waste)
14 kg/h per burner (2 burners)

Combustion chamber and flue gas records:
Parameter / Type of Waste
Solid Waste
O2 average in combustion chamber / zone
10.3 %
CO average in flue gas
107 mg/MJ
Soot number average
Bacharach 1
Combustion chamber flue gas outlet temperature average
950 °C
Amount of unburned components in ashes
8.0 %

Shock-cooling of Flue Gas:

Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:

Parameter
Solid Waste
Temperature
259 °C
Distance
2.5 m

A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.




ATTACHMENT TO
CERTIFICATE No. MED193926PU
Pages 9 of 9
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Jin Young Kim
**** NOTICE: This is NOT an official certificate ****