The MAXI T Series are intended for installation onboard ships and other marine installation for the incineration of oil residue (sludge) or solid waste. The system also enables solid waste to be added to the incinerator when operating in oil residue (sludge) mode after the incinerator has warmed up. The solid waste is then burned with the assistance from the oil residue (sludge) burner when the heat from burning solid waste is insufficient. There is an additional mode where oil residue (sludge) and bilge oil can be fed into the incinerator together. In this mode incineration begins with feeding of oil residue (sludge) until the incinerator has warmed up, then bilge oil feeding begins using a separate bilge injection burner. The feeding rate of the oil residue (sludge) and bilge oil is controlled based on temperature in the primary combustion chamber so that the maximum capacity is not exceed.
The incinerators consist of a primary combustion chamber, a secondary combustion chamber and an after-burning chamber for burning out uncombusted exhaust gases. The combustion chambers are equipped with diesel oil burners.
Solid waste is fed into the incinerator through a door system with interlocks. This enables the waste packages to be loaded through the outer door and fed into the incinerators through the inner door when the outer door is closed in cycles (i.e., continuous feeding).
Ash accumulates in the combustion chambers and may be removed from the incinerator periodically when the incinerator is cold through the ash door.
A flue gas fan is fitted in the exhaust duct or on the incinerator module to pull a negative pressure in the combustion chamber. Cooling air is pulled through a jacket around the incinerator from the compartment the incinerator is located.
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 2 of 9 |
Application
Model(*) | T50SL WS | T100SL WS | T150SL WS |
Type of solid waste loading | Continuous feed | Continuous feed | Continuous feed |
Calorific capacity kW (kcal/h) | 465 (400,000) | 768 (660,000) | 988 (850,000) |
Solid waste (kg/h) | 100 | 100 | 150 |
Oil residue (sludge) (kg/h) | 47 | 77 | 99 |
Oil residue (sludge) (kg/h) with bilge water (l/h) (**) | 60
159 bilge water | 100
200 bilge water | 128
228 bilge water |
(*) Model code SL means equipped for burning Solid waste and Oil Residue (sludge) and WS means equipped with a sluice that can be continuously load.
(**) Oil Content in bilge water is 0%.
Electrical and control components
The units are controlled through automation systems of a type tested and accepted by a nationally recognized testing agency, according to international standards. Critical components are listed in the table below:
Component Type | Component Name and Model (**) | Maker |
Programmable Logic Controller (PLC) | MICROLOGIX 1400 Series | Allen-Bradley |
| SIMATIC S7-1200 Series | Siemens |
Human Machine Interface (HMI) | PV Plus 700 Series | Allen-Bradley |
| Pro-face GP4401 Series | Schneider Electric |
Flame Detection Replay | HRE-4X | Hyundai Marine Machinery Co., Ltd. |
Flame detector | Flame detection photocell QRB Series | Siemens AG |
(** ) The system can be configured with either a Allen-Bradley PLC and HMI or a Siemens PLC and HMI.
Change to these components are to be approved by RINA. Documentation confirming the approval are to be kept together with the certificate, or the certificate is to be updated.
The software and firmware editions are listed in the table below:
Component | Software/Firmware Edition | Date |
Allen-Bradley MICROLOGIX 1400 Series | Software : RS LOGIX 500V8.XX
Firmware : 1.X | 2016 |
Siemens SIMATIC S7-1200 | Software : TIA POTAL V13.XX
Firmware : 10.X | 2016 |
Allen-Bradley PV Plus 700 Series (HMI) | Software : FT VIEW STUDIO V7.XX
Firmware : 10.X | 2016 |
Schneider Electric Pro-face GP4401 Series (HMI) | Software : GP-Pro EX V4.XX
Firem 4.X | 2016 |
Changes in the software which can alter the performance of the systems is to be approved by RINA. Note that testing of the system with the revised software may be required. Documentation confirming the approval (and any testing) are to be kept together with the certificate, or the certificate is to be updated.
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 3 of 9 |
Basic of acceptance
Capacity and emissions testing according to IMO Res.MEPC.244(66) Annex I were carried out on the MAXI T50SL WS, MAXI T100SL AND MAXI T150SL WS models and the results are given in the Appendices to this certificate.
Electrical and mechanical control devices have been assessed according to IMO Res.MEPC.244(66) 3.14.1.7 based on certificate according to internal standards accepted by a national recognized testing agency. The control pannels for the MAXI T50SL WS, MAXI T100SL WS and MAXI T150SL WS models were each subjected to a function test in 2000 and the final test reports are listed in the "Test Reports" section of this certificate. The control system was changed from a relay type to a PLC type in 2008 and so a new function test on a MAXI T150SL WS was conducted. The test report is listed in the "Test Reports" section of this certificate. The MAXI T Series all use the same control system and so the test can be considered applicable to all models.
Inclination requirements according to IMO Res.MEPC.244(66) Section 6.2 were assessed during the testing of the MAXI T50SL WS, MAXI T100SL WS and MAXI T150SL WS models.
Prototype tests according to IMO Res.MEPC.244(66) Section 7.1 were carried out on the MAXI T150SL WS model and the final report is listed in the "Test Reports" section of this certificate. This test can be considered applicable to all models.
The series of incinerators with capacities from 465 kW to 989 kW use the same basic design. Therefore, testing presented in the Appendices is considered sufficient to cover all models
The testing described above for solid waste was done under the authority of Bureau Veritas who issued EU MED Module B certificate no. 09529/C2 EC. The testing described above for oil residue (sludge) for the other models was done under the authority of Korean Register on behalf of the Republic of Korea.
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 4 of 9 |
Technical Documentation
- Technical drawings and Manual, filed by RINA approved drawing no.PUMC-27813, 27814& 27816 as outlined below.
Drawing no. | Revision | Date | Description/name | Model |
VHS-T050SL WS-1 ~ 3 | R0 | 2016.04.12. | Main specification | MAXI T50SL WS |
VHS-T100SL WS-1 ~ 3 | R0 | 2016.04.12. | Main specification | MAXI T100SL WS |
VHS-T150SL WS-1 ~ 3 | R0 | 2016.04.12. | Main specification | MAXI T150SL WS |
VHS-LOCSA-STD-1 | R0 | 2016.04.12. | List of control /Safety / Automation | All Model |
VHS-PROCEDIA-STD-1 | R0 | 2016.04.12. | Process diagram incinerator | All Model |
HIE-P04020020 | R2 | 2016.03.24. | Piping diagram | MAXI T50SL WS |
HID-T052003 | R2 | 2016.03.24. | Outline dimension drawing | MAXI T50SL WS |
HID-BOD05203 | R7 | 2013.04.30. | Assembly drawing of Basis part | MAXI T50SL WS |
HMW-WT052001 ~ 5 | R1 | 2013.04.30. | Assembly drawing of Refractory Lining | MAXI T50SL WS |
HIE-WT102004 | R2 | 2016.03.24. | Piping diagram | MAXI T100SL WS |
HID-T1000203 | R2 | 2016.03.24. | Outline dimension drawing | MAXI T100SL WS |
HID-BOD100203 | R7 | 2013.04.30. | Assembly drawing of Basis part | MAXI T100SL WS |
HMW-WT102001 ~ 5 | R1 | 2013.04.30. | Assembly drawing of Refractory Lining | MAXI T100SL WS |
HIE-WT152004 | R2 | 2016.03.24. | Piping diagram | MAXI T150SL WS |
HID-T152003 | R2 | 2016.03.24. | Outline dimension drawing | MAXI T150SL WS |
HID-BOD15203 | R5 | 2013.04.30. | Assembly drawing of Basis part | MAXI T150SL WS |
HMW-WT152001 ~ 5 | R1 | 2013.04.30. | Assembly drawing of Refractory Lining | MAXI T150SL WS |
HID-VM1502210 | R0 | 2013.04.30. | Detail drawing of Cleaning cover | All Model |
HID-S12002010 | R1 | 2013.04.30. | Assembly drawing of Waste sluice | All Model |
AT-ABB0500 | R1 | 2008.01.01 | Outline of primary blower | MAXI T50SL WS |
AT-ABBT1500 | R1 | 2008.01.01. | Outline of primary blower | MAXI T100SL WS |
AT-ABBT1500 | R1 | 2008.01.01. | Outline of primary blower | MAXI T150SL WS |
HIF-NGTSTD002 ~ 4 | R2 | 2016.03.24 | ELECTRIC PANEL-LAYOUT/FRONT | All Model |
HIF-NGTSTD005 ~ 7 | R2 | 2016.03.24 | ELECTRIC PANEL-LAYOUT/FRONT | All Model |
HIF-NGTSTD008 | R2 | 2016.03.24 | ELECTRIC PANEL-CONTROL SOURCE | All Model |
HIF-NGTSTD015 ~ 24 | R2 | 2016.03.24 | ELECTRIC PANEL-CIRCUIT DIAGRAM | All Model |
HIF-NGTSTD025 | R2 | 2016.03.24 | ELECTRIC PANEL-CIRCUIT OPTION | All Model |
HIF-NGTSTD030 | R2 | 2016.03.24 | ELECTRIC PANEL-EXTERNAL SIGNAL | All Model |
HIF-NGTSTD040 ~ 43 | R2 | 2016.03.24 | ELECTRIC PANEL-PART LIST | All Model |
HIF-NGTSTD501 ~ 3 | R2 | 2016.03.24 | ELECTRIC PANEL-TERMINAL STRIP | All Model |
HNP-MAXINC-EPA7 | R7 | 2011.11.26 | MAIN NAME PLATE | All Model |
NP-SIMENS-OPAPLC-NGT | R7 | 2014.09.11 | OPERATION INSTRUCTION PLATE | All Model |
NP-WNPLC | R9 | 2014.09.11 | WARNING PLATE | All Model |
HINC-PGM-MAXIJAL | R0 | 2015.09.11 | PLC LADDER SYSTEM SOFTWARE QUALITY PLAN | All Model |
V13-NGDO(PLC_SIMENS) | R13 | 2015.06.03 | INSTRUCTION MANUAL (NG25 ~ NG150) | All Model |
V13-BIG(PLC_SIMENS) | R13 | 2015.06.03 | INSTRUCTION MANUAL (MAXI 1200, 1500) | All Model |
V13-TDO(PLC_SIMENS) | R13 | 2015.06.03 | V13-TDO(PLC_SIMENS) | All Model |
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 5 of 9 |
Capacity and Emission tests, and safety and control tests:
- Type approval test procedure & report for waste oil incinerator, MAXI T100 SL WS, Hyundai Marine Machinery Co., Ltd., document no.MEDHS10-06, Type Test Report No.HTTR-1314, dated 26 May 2000. (Witnessed by Bureau Veritas)
- Type approval test procedure & report for waste oil incinerator, MAXI T150 SL WS, Hyundai Marine Machinery Co., Ltd., document no.MEDHS10-06, Type Test Report No.HTTR-1259, dated 25 April 2000. (Witnessed by Bureau Veritas)
- MAXI type W.O. incinerator test report, Hyundai Marine Machinery Co., Ltd., report No.HFTR-IMOT50, dated 3 November 2008. (Witnessed by Korean Register on behalf of the Republic of Korea.)
- MAXI type W.O. incinerator test report, MAXI NG150SL WS, Hyundai Marine Machinery Co., Ltd., report HFTR-IMONG150 dated 13 Februray 2004. (Witnessed by Korean Register on behalf of the Republic of Korea.)
- Test reports, filed by RINA approved drawing no.PUMC-27815.
Safety and control tests (prototype tests according to IMO Res.MEPC.244(66) Section 7.1):
- Shipboard incinerator Final Test Report, Type MAXI T150SL WS (PLC Type), Hyundai Marine Machinery Co., Ltd., Test Report No.HTTR-S3617, dated 28 May 2008. (Witnessed by Bureau Veritas)
Marking of product
For traceability to this type approval, each incinerator is to be marked with:
- Manufacturer's name or trade mark
- Style, type, model or other manufacturer's designation for the incinerator (i.e., model name with serial number)
- Capacity (net design heat release)
Note
- This certificate annuls and replaces the certificate No. MED247225PU dated 01-04-2026 due to change of the applicant's
address.
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 6 of 9 |
Appendix - Tests on MAXI T50SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI T50SL WS |
Place and date of tests | Seoul, 3 November 2004. (Witnessed by Korean Register on behalf of the Republic of Korea) |
Max. capacity | 480 kW (with Oil Residue (sludge)) |
Oil Residue (sludge) | 51.4 l/h
34,160 KJ/kg (25% water content) |
Pilot Fuel Consumption (Oil Residue (sludge)) | 0 kg/h per burner |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Oil Residue (sludge) |
O2 average in combustion chamber / zone | 10.9 % |
CO average in flue gas | 21.2 mg/MJ |
Soot number average | Bacharach 1 |
Combustion chamber flue gas outlet temperature average | 899 °C |
Amount of unburned components in ashes | 0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Oil Residue (sludge) |
Temperature | 321 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 7 of 9 |
Appendix - Tests on MAXI T100SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI T100SL WS |
Place and date of tests | Seoul, 26 May 2000 (witnessed by Bureau Veritas) |
Max. capacity | 340 kW (with Solid Waste) |
Solid Waste | 103.5 kg/h IMO Class 2
11,776 KJ/kg |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner (2 burners) |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste |
O2 average in combustion chamber / zone | 10.0 % |
CO average in flue gas | 96.0 mg/MJ |
Soot number average | Bacharach 1 |
Combustion chamber flue gas outlet temperature average | 950 °C |
Amount of unburned components in ashes | 9.0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste |
Temperature | 320 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.
 | ATTACHMENT TO
CERTIFICATE No. MED193926PU
Page 8 of 9 |
Appendix - Tests on MAXI T150SL WS
Form of IMO Type Approval Certificate for Shipboard Incinerator with Capacities of up to 4,000 kW
This is to certify that the shipboard incinerator listed has been examined and tested in accordance with the Standard for Shipboard Incinerators for disposing of ship-generated waste, as amended by resolution MEPC.244(66), and as required by regulation 16.6.1 of MARPOL Annex VI.
Test Data:
Incinerator manufactured by: | Hyundai Marine Machinery Co., Ltd. |
Incinerator type and model | MAXI T150SL WS |
Place and date of tests | Seoul, 25 April 2000 (witnessed by Bureau Veritas) |
Max. capacity | 509 kW (with Solid Waste) |
Solid Waste | 150 kg/h IMO Class 2
11,776 KJ/kg |
Pilot Fuel Consumption (Solid Waste) | 14 kg/h per burner (2 burners) |
Combustion chamber and flue gas records:
Parameter / Type of Waste | Solid Waste |
O2 average in combustion chamber / zone | 10.3 % |
CO average in flue gas | 107 mg/MJ |
Soot number average | Bacharach 1 |
Combustion chamber flue gas outlet temperature average | 950 °C |
Amount of unburned components in ashes | 8.0 % |
Shock-cooling of Flue Gas:
Temperature of the flue gas should be shock-cooled to a maximum 350 °C within 2.5 m from the combustion chamber flue gas outlet:
Parameter | Solid Waste |
Temperature | 259 °C |
Distance | 2.5 m |
A copy of this certificate should be carried out on board a vessel fitted with this equipment at all times.