MED459226CS!001ENGD- -  -  N- KERAPOXY -N- S- S- -04/09/2026- Marine Equipment- - SN- S- - N-  - 692,001B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED459226CS/001- N-Sep 3, 2031692001
 
Form
  Marine Equipment(TO)
Certification N. MED459226CS/001 - (ENG)
Certificate date 04/09/2026
Type Protezione antincendio
Product Surface materials and floor coverings with low flame-spread characteristics: (a) decorative veneers
Item Nº MED/3.18a
USCG Category N° 164.112

Model or Denomin.
Items
KERAPOXY
Applicant MAPEI SPA
Place of requester VIA CARLO CAFIERO, 22  %  20158 Milano (MI)  % ITALY
Tel. N.,Fax, Email 023767371, 0237673214, leoni@mapei.it
Directive (EU) 2026/1434
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg. II-2/3, SOLAS 74 Reg. II-2/5, SOLAS 74 Reg. II-2/6, SOLAS 74 Reg. X/3, IMO Res. MSC.36(63)-(1994 HSC Code) 7,IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO MSC/Circ.1120.
Request 31/07/2026
Expire date 03/09/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED459226CS/001

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2026/1434.
MED Item Nº MED/3.18a
USCG Category Nº 164.112
Description Surface materials and floor coverings with low flame-spread characteristics: (a) decorative veneers
Type KERAPOXY
Applicant MAPEI SPA
VIA CARLO CAFIERO, 22,20158 Milano (MI),ITALY
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg. II-2/3, SOLAS 74 Reg. II-2/5, SOLAS 74 Reg. II-2/6, SOLAS 74 Reg. X/3, IMO Res. MSC.36(63)-(1994 HSC Code) 7,IMO Res. MSC.97(73)-(2000 HSC Code) 7, IMO MSC/Circ.1120.
Issued in Genoa on
This Certificate is valid until
September 4, 2026
September 3, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED459226CS/001
Page 1 of 2

Product description

Adhesive / sealing paste deposited on a non-combustible support.
  • Composition: 71% Sand - 18% Epoxy resins - 9% Amines - 1% Pigments - 1% Benzyl Alcohol.
  • Thickness: 0.25 mm;
  • Weight: 370 g/m2 (± 5%);
  • Density: 1550 kg/m3.
Field of application

As finishing material for all exposed interior and concealed or inaccessible surfaces (decorative veneer).

The product may be applied to any non-combustible (non metallic) support having a thickness equal to or greater than 25 mm and a density ³ 712.5 kg/m3.

Gross calorific Value results to be considered whenever the prescription to be less than 45 MJ/m2 is applicable.
The compliance is valid for the Kerapoxy by MAPEI having weight of 370 g/m2 and the relevant tolerance of ± 5% may be applied on the percentages of the components.
Tests carried out

Tests as per LAPI Laboratory Reports No. 944.4IM0080/11, No. 944.4IM0090/11 and No. 944.4IM0100/11 dated 7 September 2011 issued according to:
  • IMO 2010 FTP Code Part. 5;
  • IMO 2010 FTP Code Part. 2:
  • ISO 1716:2010.




ATTACHMENT TO
CERTIFICATE No. MED459226CS/001
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****