ELE625524WSENGD- -  -  N- GCS800 -N- S- S- -31/12/2024- Prodotti Elettrici- - SN- N- - N-  - 1,242,053BbisProdotti ElettriciNumero Pratica,NumDich,Norma,NumBusta,Richiesta,Validità- ELE625524WS- N-Dec 30, 20291242053
 
Form
  Prodotti Elettrici(TO)
Certification N. ELE625524WS - (ENG)
Certificate date 31/12/2024
Type Impianti Elettrici
Product Integrated Gauging, Monitoring-Alarm and Controlling System

Model or Denomin.
Items
GCS800
Applicant AQUASYNC INNOVATION (ZHEJIANG)CO.,LTD.
Place of requester Room 308, Building 4, No. 209 Gaoerfu Road, Dongzhou Sub-district, Fuyang District Hangzhou (Zhejiang)  % CHINA
Tel. N.,Fax, Email +86 18930831035, ---,William.Wu@aquasync.tech
Standards IACS UR E27 Rev.1 Cyber Resilience of On-board systems and equipment, RINA Rules for Classification of Ships Pt C, Ch 3,Sec 4 & 5.
Expire date 30/12/2029
Responsible Office SHANGHAI
Interrut.senza Dettaglio ENG
Vuoto Querysave
S
TYPE APPROVAL CERTIFICATE
No. ELE625524WS
This is to certify that the product below is found to be in compliance with the applicable requirement of the RINA type approval system.

Description Integrated Gauging, Monitoring-Alarm and Controlling System
Type GCS800
Applicant AQUASYNC INNOVATION (ZHEJIANG)CO.,LTD.
Room 308, Building 4, No. 209 Gaoerfu Road, Dongzhou Sub-district, Fuyang District Hangzhou (Zhejiang)
CHINA
Reference standards IACS UR E27 Rev.1 Cyber Resilience of On-board systems and equipment, RINA Rules for Classification of Ships Pt C, Ch 3,Sec 4 & 5.
  

 
 
   .   This Certificate is valid until December 30, 2029
_________________________________
RINA Services S.p.A.
Hai Wen Zhang
This certificate consists of this page and 1 enclosure
**** NOTICE: This is NOT an official certificate ****

TYPE APPROVAL CERTIFICATE
No. ELE625524WS
Enclosure - Page 1 of 3
GCS800
1. PRODUCT DESCRIPTION:

+ Integrated Gauging, Monitoring Alarm and Controlling System is based on modular design using standard modules,mainly composed by power units,operator workstations,displays,Ethernet switches,communication modules,PLC and I/O modules.It mainly includes the following functions:


1.Monitoring and Alarm(Including Engineer Alarm).
2.Control System for Valve/Motor/Fan/Cargo/Other aux.machineries and Level Gauging.
3.Pressure, Temperature and Liquid Level Measurement.

+ Main Components and approval range:
No.
Name
Mode
Manufacturer
1
PLC & I/O Modules
S7-1200 series
Siemens
2
PLC & I/O Modules
S7-1500 series
Siemens
3
PLC & I/O Modules
ET200SP series
Siemens
4
Operator Station
Elite SFF 800 G9 Desktop PC
HP
5
Monitor
E24 G5 FHD Monitor
HP
6
Touch Screen
X2pro series
Beijer
7
Extend Alarm Board
SEP-A07
ASI
8
Switch Power Supply
PRO MAX Series
Weidmuller
9
Power Redundancy Module
PRO RM Series
Weidmuller
10
Industry Switch
XC200 series
Siemens
11
Industry Switch
SUP-5216
ASI
12
Industry Switch
SIE-1008
ASI
13
Firewall
SO-MFW-100M
ASI
14
Alarm Board
EAP-12/EAP-16/EAP-24
ASI
15
UPS
UPS2000-A-1KTTS 1KVA
HUAWEI
16
UPS
UPS2000-A-2KTTS 2KVA
HUAWEI
17
UPS
UPS2000-A-3KTTS 3KVA
HUAWEI
18
DMAS Start/stop and Reset Push Buttons
PB-01
ASI
19
Extended Alarm Buzzer
BUZ-01
ASI
20
Hydraulic Pump Station
HPU-150/HPU-250
ASI
21
Solenoid Valve Box
SV1800
ASI
22
Heeling Alarm Panel
ALM-01
ASI
23
Audible and Visual Warning Light
SED/SESA
ASI
24
Temperature Sensor
WZP Series
ASI
25
Float Level Switch
SL20 Series
ASI
26
Radar Level Transmitter
SL901/SL906/SL906S
ASI
27
Pressure Transmitter
SMP131 Series, LMP633 Series, CXT Series
ASI



TYPE APPROVAL CERTIFICATE
No. ELE625524WS
Enclosure - Page 2 of 3



+ Main Components and approval range:
No.
Name
Mode
Manufacturer
28
Alarm printer
LQ-300 series
EPSON
29
Laser 150 Printer series
HP
30
Laser 103a series
HP
31
Safety Barrier
F1-DI1-1111
ASI
32
F2-AI1-CCCC
ASI
33
F2-TP1-99CC
ASI
34
HD5516
ASI
35
HD5544
ASI
36
HD5573
ASI

+ Software version
Software components
name
Revision
Operating System
Windows 10&11 professional
1809&22H2
Industrial terminal protection software
Marine defender system
V2.20.00.00
PLC Monitoring Software
WinCC 8.0&8.1
8.0&8.1
PLC Configuration Software:
TIA Portal
V19&V20
2. Testing:

+ Integration testing of the GCS800 has been carried out on a Simulation environment according to requirements of IACS UR E27, IEC 62443-3-3 SL1 and RINA Rules, witnessed by RINA on 28 Oct 2024. The test program included the following tests:
No.
Test standards IEC 62443-3-3
No,
Test standards IEC 62443-3-3
1
SR 1.1 – Human user identification and authentication .
17
SR 2.10 – Response to audit processing failures
2
SR 1.3 – Account management
18
SR 2.11 – Timestamps
3
SR 1.4 – Identity management
19
SR 3.2 – Malicious Code Protection
4
SR 1.5 – Authorization Enforcement
20
SR 3.3 – Safety Function Verification
5
SR 1.7 – Strength of password-based authentication
21
SR 3.5 – Input validation
6
SR 1.10 – Authenticator feedback
22
SR 3.6 – Deterministic output
7
SR 1.11 – Failed login attempt
23
SR 4.3 – Using encryption
8
SR 1.12 – System usage notification
24
SR 6.1 – Audit log accessibility
9
SR 2.1 – Authorization Implementation
25
SR 7.1 – Anti Denial of Service Attack
10
SR 2.2 – Wireless usage control
26
SR 7.2 – Resource management
11
SR 2.3 – Control of the use of portable and mobile devices
27
SR 7.3 – System backup
12
SR 2.4 – Mobile Code
28
SR 7.4 – Control system recovery and reconstruction
13
SR 2.5 – Session lock
29
SR 7.5 – Power supply
14
SR 2.6 – Remote session termination
30
SR 7.6 – Network and security configuration settings
15
SR 2.8 – Auditable events
31
SR 7.7 – Least functionality
16
SR 2.9 – Audit storage capacity

TYPE APPROVAL CERTIFICATE
No. ELE625524WS
Enclosure - Page 3 of 3

2. REFERENCE DOCUMENTS:

+ GCS800-CS-01_1_Secure development lifecycle. Filed by RINA with drawing No. SHEL 21480.
+ GCS800-CS-02_1_Description of system security capabilities. Filed by RINA with drawing No. SHEL 21481.
+ GCS800-CS-03_1_System security configuration. Filed by RINA with drawing No. SHEL 21482.
+ GCS800-CS-04_1_Management of change plan. Filed by RINA with drawing No. SHEL 21483.
+ GCS800-CS-05_1_Information supporting incident response and recovery plans. Filed by RINA with drawing No. SHEL 21484.
+ GCS800-CS-06_1_Plans for maintenance and verification. Filed by RINA with drawing No. SHEL 21485.
+ GCS800-NE-06_2_System asset inventory. Filed by RINA with drawing No. SHEL 21486.
+ GCS800-NE-07_1_System topology diagram. Filed by RINA with drawing No. SHEL 21487.
+ Test Report witnessed and signed by our attending Surveyor on date October, 28, 2024. Filed by RINA with drawing No. SHEL21492.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-21490.
+ System documentation. Filed by RINA with drawing No. SHEL-21824, SHEL-21826 and SHEL-21827.
+ Software documentation. Filed by RINA with drawing No. SHEL-21830, SHEL-21831 and SHEL-21832.

3. Note/Remark:
+ The validity of this Certificate is subject to maintenance of the initial product conditions verified by RINA Services.
Changes to the initial conditions must be communicated to RINA Services which reserves the right to carry out further verification activity to confirm the validity of this Certificate.
+ The rules, surveys and activities performed by RINA, reports, certificates and other documents issued by RINA
are in no way intended to replace the duties and responsibilities of other parties such as Governments, designers,
ship builders, manufacturers, repairers, suppliers, contractors or sub-contractors, owners, operators, charterers,
underwriters, sellers or intended buyers of a ship or other product or system surveyed.

SHANGHAI December 31, 2024