MED057326CSENG- -  -  N- VTN-FWD TYPE A60 FIRE DOORS -N- S- S- -29/04/2026- Marine Equipment- - SN- S- - N-  - 2,347,908B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED057326CS- N-Apr 28, 20312347908
 
Form
  Marine Equipment(TO)
Certification N. MED057326CS - (ENG)
Certificate date 29/04/2026
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
VTN-FWD TYPE A60 FIRE DOORS
Applicant Zhuhai VTN Yacht Equipment Co.,Ltd.
Place of requester Room 101, 1st Floor, No. 22 Yong'an Road, Lian'gang Industrial Zone, Hongqi Town, Jinwan District Zhuhai (Guangdong)  % CHINA
Tel. N.,Fax, Email +86 18138682208; fangyuan@vtninox.com
Directive (EU) 2025/1533
Standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ.1319
Reference Documents SOLAS 74 Reg. II-2/9,IMO MSC.1/Circ. 1511/Rev.1
Request 23/01/2026
Expire date 28/04/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED057326CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type VTN-FWD TYPE A60 FIRE DOORS
Applicant Zhuhai VTN Yacht Equipment Co.,Ltd.
Room 101, 1st Floor, No. 22 Yong'an Road, Lian'gang Industrial Zone, Hongqi Town, Jinwan District Zhuhai (Guangdong),CHINA
Testing standards IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.,IMO MSC.1/Circ.1319
Reference standards SOLAS 74 Reg. II-2/9; IMO MSC.1/Circ. 1511/Rev.1
Issued in Genoa on
This Certificate is valid until
April 29, 2026
April 28, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED057326CS
Page 1 of 2

Product description



Hinged door with a maximum clear opening of 1000 × 2100 mm. The leaf, having a maximum dimension of 1017 × 2171 mm and 70.5 mm thick, is composed, starting from the hinge side, of a 6 mm thick carbon steel plate, an insulation package consisting of: one layer of inorganic fireproof core board (Suzhou Youlian Ship Fitting Co., Ltd, type YB) with a thickness of 10 mm and a density of 1000 kg/m³; two layers, each 21.5 mm thick, of ceramic fiber (Yixing Ocean Ship Material Co., Ltd, type TG-II) having thickness of 30 mm and a density of 170 kg/m³ each; one layer of inorganic fireproof core board (Suzhou Youlian Ship Fitting Co., Ltd, type YB) with a thickness of 10 mm and a density of 1000 kg/m³; and a 1.5 mm thick carbon steel plate. The mineral wool is glued to the steel plate with 500g/m2 adhesive Shanghai Ningrui Adhesives Science & Technology development Co., Ltd type YB2002X.
On the 6 mm plate of the leaf, an L-shaped carbon steel stiffener of dimensions 100x63 mm and thickness 10 mm is welded along the perimeter; to this stiffener, the 1.5 mm carbon steel plate is bolted using carbon steel bolts M5 with a pitch of 270 mm. The L-shaped stiffener is insulated with a layer of inorganic fireproof core board (Suzhou Youlian Ship Fitting Co., Ltd, type YB) with a thickness of 10 mm and a density of 1000 kg/m³. Inside the leaf, four horizontal stiffeners are welded onto the 6 mm plate, with a pitch of 402 mm, consisting of a carbon steel flat bar with dimensions 53 × 12 mm. The door frame is made of an L-shaped carbon steel profile with dimensions 100 × 63 mm and a thickness of 10 mm, bolted to the bulkhead with M6 carbon steel bolts at a pitch of 160 mm. The frame is insulated on the exposed side, over 200 mm, with two layers of Zibo Huayuan New Maerials Co., Ltd ceramic fiber type HYSF Type Huayuan Marine Super Fireproof Wool, each having a density of 140 and a thickness of 30, fixed with pins having pitch from 160 to 340 mm.
Inside the shaped profile of the leaf on the hinge side, an EPDM gasket Hebei Meikui, type QH 01, with dimensions 45 × 20 mm is provided. Along the perimeter edge of the leaf, an intumescent gasket Shanghai Gallford, type YZ2004 with dimensions 20 × 8 mm is installed.
The leaf is equipped with three hinges (Zhuhai Vtn Yacht Equpment Co., Ltd type VTN-FWD-00-05-01 ) and a lever-operated locking system located on the side opposite the hinges, acting on 12 stainless steel bolts operated by a handwheel (Zhuhai Vtn Yacht Equpment Co., Ltd type VTN-FWD-00-05-01 ) positioned on both sides of the leaf.
Field of application

Fire resistant A-60 Class single leaf hinged door intended for general applications, in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.

In case of doors in compliance to the "Agreement between the European Community and the United States of America", the present certificate is valid at the following conditions:
- doors without windows;
- maximum door size tested;
- door used with a fire tested frame design.
Reference documents

Zhuhai Vtn Yacht Equpment Co., Ltd drawings No. VTN-FWD-T dated 07/02/2026 enclosed on Test report No. SDFTS25006648R01-1_EN dated 28/04/2026.
Tests carried out

Test as per SGS Laboratory report No.SDFTS25006648R01-1_EN dated 28/04/2026 issued according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED057326CS
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****