MED160926CSENG- -  -  N- NEMEA EME DOOR -N- S- S- -20/04/2026- Marine Equipment- - SN- S- - N-  - 781,145B2bisMarine EquipmentNumero Pratica,Direttiva,Norma,Schema,Richiesta,Validità,EmailR- MED160926CS- N-Apr 19, 2031781145
 
Form
  Marine Equipment(TO)
Certification N. MED160926CS - (ENG)
Certificate date 20/04/2026
Type Protezione antincendio
Product Porte tagliafuoco
Item Nº MED/3.16
USCG Category N° 164.136

Model or Denomin.
Items
NEMEA EME DOOR
Applicant OLCESE RICCI S.R.L.
Place of requester VIA E. CAORSI 49 A  %  16030 Sori (GE)  % ITALY
Tel. N.,Fax, Email 0185700425; d.oteri@olcesericci.com
Directive (EU) 2025/1533
Standards IMO MSC.1/Circ.1319,IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference Documents SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Request 06/03/2026
Expire date 19/04/2031
EC TYPE-EXAMINATION (MODULE B) ENG
Vuoto Querysave
Enrico Cabella S

EC TYPE EXAMINATION (MODULE B)
CERTIFICATE No. MED160926CS

This is to certify that RINA Services S.p.A. (Notified Body No. 0474) did undertake the relevant type approval procedures for the equipment identified below, which was found to be in compliance with the Fire Protection requirements of Marine Equipment Directive (MED) 2014/90/EU, including the requirements and testing standards of Regulation (EU) 2025/1533.
MED Item Nº MED/3.16
USCG Category Nº 164.136
Description Fire doors
Type NEMEA EME DOOR
Applicant OLCESE RICCI S.R.L.
VIA E. CAORSI 49 A,16030 Sori (GE),ITALY
Testing standards IMO MSC.1/Circ.1319,IMO Res. MSC.307(88)-(2010 FTP  Code), as amended.
Reference standards SOLAS 74 Reg.II-2/9, IMO MSC.1/Circ.1511/Rev.1
Issued in Genoa on
This Certificate is valid until
April 20, 2026
April 19, 2031
This Certificate consists of this sheet plus an attachment

________________________________________
Enrico Cabella
RINA Services S.p.A.
**** NOTICE: This is NOT an official certificate ****

ATTACHMENT TO
CERTIFICATE No.  MED160926CS
Page 1 of 2

Product description

Hinged door installed on an aluminum bulkhead, with a clear view of 900 x 1900 mm. The leaf, having dimensions of 1017 x 2017 mm and a thickness of 86 mm, is composed, starting from the side opposite the hinges, of a 3 mm thick stainless steel sheet, an insulation package consisting of a layer of mineral wool Rockwool SeaRox SL 640 with a density of 130 kg/m³ and thickness of 30 mm, a layer of PROMAGUARDALU with thickness 10 mm and density 240 kg/m³, a further layer of mineral wool Rockwool SeaRox SL 640 with density 130 kg/m³ and thickness 30 mm, and a 4 mm thick carbon steel sheet. On the 4 mm sheet of the leaf, the following stiffeners are provided: 5 horizontal stiffeners, with a variable pitch from 118 to 552 mm, made of a shaped carbon steel profile with dimensions 75x20x4 mm; the connection between the external and internal sheets is achieved by means of stainless steel screws with a diameter of 6 mm and a variable pitch from 140 mm to 180 mm, fixed to an “L”-shaped carbon steel profile with thickness 4 mm and dimensions 79x30 mm, which forms the internal perimeter of the leaf. The door frame consists of an “L”-shaped carbon steel profile with dimensions 90 x 88 mm and thickness 8 mm, fixed to the aluminum bulkhead by means of M10 stainless steel bolts with a pitch of 50 mm. The frame is insulated on both the exposed and unexposed sides, for 150 mm, with two layers of mineral wool Rockwool SeaRox SL620 each having thickness 30 mm(#) and density 100 kg/m³, fixed with pins at a variable pitch from 100 to 350 mm. On the folded rebate edge of the leaf, hinge side, a gasket EME Gasket CSI 400 FF with dimensions 35x20 mm is provided; on the side opposite the hinges, a gasket EME Gasket CSI 400 FF with Soliani EMC sleeve with dimensions 30x15 mm is provided. Along the perimeter edge of the leaf, an intumescent gasket Promaseal LSK is provided, with a width of 60 mm and thickness of 2.5 mm. The leaf is equipped with 3 hinges and a lever-operated closing system positioned outside the door, acting on 3 stainless steel bolts operated by a central handle provided on both sides, and a stainless-steel lock of type Olcese Ricci lock. The door is also fitted with a window having a clear view of 400x300 mm, composed of AGC Pyrobel 25 EI60 glass with a total thickness of 26.6 mm, consisting of 5 laminated glass panes with an interlayer of intumescent gel. The glass is contained within a “Z”-shaped stainless-steel profile with dimensions 27x30x28 mm and thickness 2 mm, fastened with 8 M5 bolts with a pitch of 200 mm. Between the frame and the glass, and along the perimeter of the glass, a layer of silicate Superwool Plus Blanket with thickness 6 mm and density 96 kg/m³ is provided, together with a bead, on each side, of silicone Promat Systemglas Sealant placed between the end of the gasket and the end of the frame.
Field of application
Fire resistant A-60 Class single leaf hinged door installed on aluminum bulkhead.
The door is also in compliance with IMO MSC.1/Circ. 1319 dated 11 June 2009. In this case the dimensions relevant to the height and width of the door may be increased of 15% provided that the surface area is not increased of more than 10%.
In case of doors in compliance to the "Agreement between the EEA EFTA States and the United States of America", the present certificate is valid at the following conditions:
- doors without windows or with total window area no more than 645 cm2 in the door leaf;
- maximum door size tested;
- door used with a fire tested frame design.
Reference documents
Olcese Ricci drawing No. "Nemea EME Door 27548" Rev. 00 dated 05/03/2026 enclosed on Test Report N.2026CS011609 dated 20/04/2026 .
Tests carried out
Tests as per RINA Test Laboratory Report No. 2026CS011609 dated 20/04/2026 issued according to IMO 2010 FTP Code Part 3.




ATTACHMENT TO
CERTIFICATE No. MED160926CS
Pages 2 of 2
The mark of conformity may only be affixed to the above type approved equipment and a Manufacturer's Declaration of Conformity issued when the production control phase module (D, E or F) of Annex II of the Directive is fully complied with a written inspection agreement with a Notified Body
XXXX/YY
"WHEELMARK FORMAT"

XXXX
Notified Body number undertaking surveillance module
YY
Last two digits of year mark affixed
     
______________________________________________
General conditions for the approval
a) The initial conditions verified by RINA at the time of the approval are to be maintained
b) Any changes to the initial conditions are to be promptly communicated to RINA, which reserves the right to repeat the relevant assessment
c) This certificate will no be valid if the manufacturer makes any changes or modifications to the approved equipment, which have not been notified to, and agreed with RINA
d) RINA personnel are to be allowed to witness during the performances of activities, upon their request
e) The activities are to be carried out in compliance with the RINA Rules and/or other applicable Rules

f) Should the specified regulations or standards be amended during the validity of this certificate, the product is to be reapproved prior to it being placed on board vessels to which the amended regulations or standards apply. 


__________________________________________
Enrico Cabella
**** NOTICE: This is NOT an official certificate ****