Penetration of metallic pipes having diameter ranging from 6 mm up to 170 mm installed in A-Class aluminium bulkheads and decks. These transits are composed of EPDM cylindrical body, stainless steel discs on the extremities and screws for the expander mechanism, fitted inside a circular aluminium coaming welded in the middle, on both sides, to the deck or bulkhead plate. The transits are insulated, on both sides, with two layers of mineral wool type SeaRox SL 620 or PAROC Fire Slab 100, having density of 100 kg/m3 and, each, thickness of 60 mm; the mineral wool panels, having dimensions ranging from 240x240 mm up to 420x420 mm, are fixed to the bulkhead or deck plate by means of bi-metallic pins and washers welded with pitch ranging from 150 up to 200 mm. The pipes are insulated, on both sides, by means of a two layers of mineral wool cylinder type ProRox WM 960, 30 mm thick each and having density of 100 kg/m3 and length 350 mm for the steel pipes and of 450 mm for other metallic pipes.
|
ATTACHMENT TO
CERTIFICATE Nr. MED194722CS/001
Page 2 of 3 |
Field of application
Fire resistant metallic pipes penetrations through aluminium bulkheads and decks as per following tables:
Transit type | pipe type | Minimum diameter (mm) | Maximum diameter (mm) | Class |
WR | Only steel | 6 | 170 | A-60 |
WR | All metallic pipes | 6 | 133 | A-60 |
Reference documents
WallMax drawing Nos. 5500002002, 5500001004 and 5500001003 dated 25 April 2017 approved on 27 april 2017 and 3 May 2017 respectively with endorsement Nos. LABS-1455, LABS-1456 and LABS-1459.
Tests carried out
Tests as per RINA Test Laboratory Reports No. 2017CS01761/1 dated 3 May 2017, No. 2017CS01761/2 dated 27 April 2017 and No. 2017CS01761/4 dated 27 April 2017 issued according to Appendix 1 of IMO 2010 FTPC Part 3 - A.III Pipe and Duct Penetration |