| Equipment:
|
|
|
|
| AI.LMV-16 |
|
|
|
|
|
|
|
| Manufacturer |
|
|
|
| ASIT ITALIA SRL A SOCIO UNICO |
|
|
|
Place of Manufacturer |
|
|
|
Via Quintino Sella, 6 10020 Riva Presso Chieri (TO) ITALY |
|
|
|
|
|
|
|
| Technical documentation |
|
|
|
| Data sheet Magnetic Level Gauge; RINA Id. ELET/45037,Technical Datasheet: Dwg. No. 210114-01; Date: 14.01.2021; RINA Id. ELET/43639,Techincal Datasheet: Dwg. No. 210114-01-D; Date: 10.06.2021; RINA Id. ELET/43640,ISO 9001:2015 Certificate No. 38785/19/S; Date: 01.10.2025; RINA Id. ELET/43642,Technical justification for the Non-Applicability of some of the Tests Required by IACS UR E10; Date: 15/07/2026; RINA Id. ELET/45039 |
| |
Intended Service
|
|
Intended service according to the EU RO Mutual Recognition Technical Requirements for Level Gauges/Transmitter. |
|
Ratings
|
|
Degree of protection IP: 65, Process/ambient temperature: 5°C up to 70°C , Measurements type: Continuois measurement |
|
Restrictions
|
|
Level Gauge intended for marine use |
|
|
|
|
|
<font size="2" face="Calibri"><b>Product Information</b></font> <p></p> <br /> <font size="2" face="Calibri">Lever indicator based on a magnetic float in bypass chamber and two colours magnetic rolling display.</font><br /> <br /> <font size="2" face="Calibri"><b>Model:</b></font><br /> <font size="2" face="Calibri">AI.LMV-16 Magnetic level gauge</font><br /> <br /> <font size="2" face="Calibri"><b>Intended Service:</b></font><br /> <font size="2" face="Calibri">Intended use according to the valid and amended EU RO Mutual Recognition Technical Requirements for Level Gauges/Transmitter to be observed. </font><br /> <br /> <font size="2" face="Calibri"><b>Description:</b></font><br /> <font size="2" face="Segoe UI">Bypass-type magnetic level indicator for tanks and vessels, consisting of an external measuring chamber communicating with the vessel, an internal magnetic float, and a bi-color magnetic display providing continuous local indication of the fluid level, without direct contact and without electrical power supply.</font><br /> <br /> <br /> <br /> <font size="2" face="Calibri"><b> Ratings:</b></font><br /> <font size="2" face="Calibri"> Chamber Operating Pressure: up to 10 Bar</font><br /> <font size="2" face="Calibri"> Operating Temperature: 5°C up to 70°C</font><br /> <font size="2" face="Calibri"> Fluid Viscosity: <600 cP (mPa-s)</font><br /> <font size="2" face="Calibri"> Limiti Fluid Density ρ: 500 to 1500 kg/dm3 </font><br /> <font size="2" face="Calibri"> Liquid Measuring range: 0.3 to 5.5 m</font><br /> <font size="2" face="Calibri"> Measuring resolution: ± 10 mm</font><br /> <font size="2" face="Calibri"> IP roller flags display (according to IEC60529): 65</font><br /> <font size="2" face="Calibri"> Requires no auxiliary power source</font><br /> <br /> <font size="2" face="Calibri"><b>Application limitations:</b></font><br /> <font size="2" face="Calibri">The Level indicator is intended for marine use. Technical installation and operation manual to be provided for each delivery. Limitation according to the valid and amended EU RO Mutual Recognition Technical Requirements for Level Gauges/Transmitter to be observed. </font><br /> <br /> <font size="2" face="Calibri"><b>Test Reports</b></font><br /> <font size="2" face="Calibri">The Level Indicator has been verified for compliance with the EU Mutual Recognition Technical Requirements for LEVEL GAUGES/TRANSMITTERS Version 0.4 dated 1 July 2026.</font><br /> <font size="2" face="Segoe UI">Based on the equipment type and application, the following tests were considered not applicable, as stated in the document "</font><font size="2" face="Segoe UI"><i>Statement on the Non-Applicability of Some of the Tests Required by IACS UR E10</i></font><font size="2" face="Segoe UI">": Damp Heat, External Power Supply Failure, Insulation Resistance, High Voltage, Salt Mist, EMC, Cold Test.</font><br /> <br /> <font size="2" face="Calibri">Environmental and EMC conditions for which the equipment has been type tested:</font><br /> <font size="2" face="Calibri">- 56,9%RH @ 29.3°C, 101,6kPa AP, visual inspection</font><br /> <font size="2" face="Calibri">- 5Hz - 100Hz, ±1mm 5Hz-13.2Hz and 0.7g 13.2Hz-100Hz, Q>2, vibration sinusoidal test</font><br /> <font size="2" face="Calibri">- 70°C @ 16hrs, dry heat test</font><br /> <font size="2" face="Calibri">- 22,5°, static and dynamic inclination test</font><br /> <br /> <font size="2" face="Calibri">TesLab Test Report No. 213077A (RINA Id. ELET/44973): Environmental Test Report; Date: 25/05/2021</font><br /> <font size="2" face="Calibri">ASIT ITALIA Test Report no. 30009B.1 (RINA Id. ELET/44974): Visual Inspection and Performance Test; Witnessed by RINA; Date: 13/07/2026.</font><br /> <font size="2" face="Calibri">Kiwa Test Report No. 160901435 (RINA Id. ELET/45038): Degree of protection test on enclosures of level indicators (IEC 60529); Date: 10/2016.</font><br /> <br /> <font size="2" face="Calibri"><b>Other informations:</b></font><br /> <font size="2" face="Calibri">EU RO MR APP dated 13.04.2026 (RINA Id. ELET/43641)</font><br /> <font size="2" face="Calibri">Offer n. 2026/12981; Job Id. RS/2026/CS/01/2621</font><br /> <font size="2" face="Calibri">Initial Audit has been carried out at the production site in date 13/07/2026 (N.2026/MI/01/570)</font><br /> <font size="2" face="Calibri">The documents above-mentioned have been archived in the Leonardo Draw Plus portal under the projects:</font><br /> <a href="https://leodrawplus.rina.org/projects/81370/detail"><font size="3" face="serif">https://leodrawplus.rina.org/projects/81370/detail</font></a><br /> <a href="https://leodrawplus.rina.org/projects/81472/detail"><font size="3" face="serif">https://leodrawplus.rina.org/projects/81472/detail</font></a><br /> <font size="2" face="Calibri">On 29/05/2026, Certificate No. EMR262126CS superseded and renewed the previous Certificate No. ELE141120CS through an upgrade to an EU RO MR Type Approval Certificate.</font><br /> <br /> <br /> <br /> <font size="2" face="Calibri"><i>When a product is presented with this EU RO MR Type Approval Certificate for given application, its acceptability with regards to the limitations stated in the certificate conditions defined in 1b, 1c and 1d of the applied Technical Requirement will be evaluated by the EU RO in charge of classing the ship or being in charge of the unit/system certification.</i></font><br /> <font size="2" face="Calibri"><i>In accordance with Article 10 of Regulation (EC) No 391/2009 of the European Parliament and of the Council of 23 April 2009 "on common rules and standards for ship inspection and survey organizations", the following organizations, recognized by the EU on this date, have agreed on the technical and procedural conditions under which they will mutually recognize this certificate:</i></font><br /> <font size="2" face="Calibri"><i>• American Bureau of Shipping (ABS);</i></font><br /> <font size="2" face="Calibri"><i>• Bureau Veritas (BV);</i></font><br /> <font size="2" face="Calibri"><i>• China Classification Society (CCS);</i></font><br /> <font size="2" face="Calibri"><i>• Croatian Register of Shipping (CRS);</i></font><br /> <font size="2" face="Calibri"><i>• DNV;</i></font><br /> <font size="2" face="Calibri"><i>• Indian Register of Shipping (IRS);</i></font><br /> <font size="2" face="Calibri"><i>• Korean Register (KR);</i></font><br /> <font size="2" face="Calibri"><i>• Lloyd's Register Group Ltd. (LR);</i></font><br /> <font size="2" face="Calibri"><i>• Nippon Kaiji Kyokai General Incorporated Foundation (ClassNK);</i></font><br /> <font size="2" face="Calibri"><i>• Polish Register of Shipping (PRS);</i></font><br /> <font size="2" face="Calibri"><i>• RINA Services S.p.A. (RINA).</i></font><br /> <br /> <br /> <font size="2" face="Calibri"><i>The scheme for the mutual recognition of class certificates for materials, equipment and components laid down by Article 10(1) of Regulation (EC) No 391/2009 is only enforceable within the Union in respect of ships flying the flag of a Member State. As far as foreign vessels are concerned, the acceptance of relevant certificates remains at the discretion of relevant non-EU flag States in the exercise of their exclusive jurisdiction, notably under the United Nations Convention on the Law of the Sea (UNCLOS). (In accordance with COMMISSION IMPLEMENTING REGULATION (EU) No 1355/2014 amending Regulation (EC) No 391/2009 - recital (25)).</i></font><br /> <br /> <br /> <font size="2" face="Calibri"><b><i>Notes:</i></b></font><br /> <font size="2" face="Calibri"><i>1) Refer to the agreed MR Technical Requirements for additional MR TAC information that may be specifically applicable to certain products - </i></font><font size="2" color="#0000FF" face="Calibri"><i><a href="https://www.euromr.org/technical-requirements">https://www.euromr.org/technical-requirements</a></i></font><font size="2" face="Calibri"><i>;</i></font><br /> <font size="2" face="Calibri"><i>2) List of MR TACs issued by the EU ROs can be found by </i></font><font size="2" color="#0000FF" face="Calibri"><i><a href="https://www.euromr.org/links-to-mrcertificates">https://www.euromr.org/links-to-mrcertificates</a></i></font><font size="2" face="Calibri"><i>.</i></font><br /> <font size="2" face="Calibri"><i>3) As per clause 9 of the Terms & Conditions for Mutual Recognition of Type Approval, the manufacturer will be required to agree that it will fulfil the obligations arising out of its quality assurance scheme as approved during production. The manufacturer certifies it has kept the accredited certification body and the EU RO that issued the MR TAC duly informed of any intended design changes or updating of the production quality assurance scheme for its consideration with regard to the validity of the MR TAC. The manufacturer will apply annually for periodical assessment by the EU RO to show that the production under the MR TAC and the quality assurance scheme are being satisfactory maintained;</i></font><br /> <font size="2" face="Calibri"><i>4) The manufacturer should notify the RO issued the EU RO MR Certificate of any modification or changes to the equipment/ Firmware/ Operational System Software Version in order to obtain a valid Certificate.</i></font><br /> <font size="2" face="Calibri"><i>5) MR TACs are valid for a maximum of 5 years as per clause 10 of the Terms & Conditions for Mutual Recognition of Type Approval;</i></font><br /> <font size="2" face="Calibri"><i>6) For more information on the factors affecting the validity of MR TACs, see clause 11, 12 and 13 of the Terms & Conditions of Mutual Recognition of Type Approval.</i></font><br /> <font size="2" face="Calibri"><i>7) For implementation of the amendments to Appendix I of Version 10.0 of the Framework Document by the EU ROs into their internal procedures and MR TAC templates, an application period of 6 months as from 1 July 2019 applies</i></font> |
|