1. Product Description
150/250V shipboard communication and instrumentation cables having following rating:
Type
Designation | Rated
Volt.
[V] | Number of
pair or triple | Nominal Conductor
Cross-sectional
Area [mm²] | Maximum rated
Conductor
Temperature [℃] | Fire Property |
CHJV, CHJV80|90|82|92, CHJ82|92
CHJVP, CHJVP80|90|82|92, CHJP82|92 (/SA, /NA )
CHJPF, CHJPF80|90|86|96, CHJ86|96
CHJPFP, CHJPFP80|90|86|96, CHJP86|96
CHJPJ, CHJPJ80|90|85|95, CHJ85|95
CHJPJP, CHJPJP80|90|85|95, CHJP85|95
(/SC, /NC, /NSC) | 150/250 | (1~48) ×2
(1~48) ×3
| 0.5~2.5
| 90 | Flame-retardant
- IEC 60332-1
- IEC 60332-3-22
Fire-resistant
- IEC 60331-1
- IEC 60331-2 |
CHEV, CHEV80|90|82|92
CHEVP, CHEVP80|90|82|92
CHEF, CHEF80|90|82|92
CHEFP, CHEFP80|90|82|92
(/SA, /NA )
CHEPF, CHEPF80|90|86|96
CHEPFP, CHEPFP80|90|86|96
CHEPJ, CHEPJ80|90|85|95
CHEPJP, CHEPJP80|90|85|95
(/SC, /NC, /NSC) |
Note: +“Conductor Cross-section” is selected from the following series of conductor size:
0.5, 0.75,1.0, 1.5, 2.5 mm2
+“Number of Core” is selected from the following series of pair or triple number:
1, 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 24, 27, 30, 33, 37, 43, 48.
+Conductor: Stranded bare or tinned annealed copper - Class 2 or 5
+Insulation: Cross-linked polyethylene -XLPE(J)
Ethylene Propylene Rubber - EPR (E)
+Inner Sheath: (Option):
Thermoset compound – SE1 (F)
Thermoplastic compound - ST2 (V)
Halogen Free Thermoplastic compound - SHF1 (PF)
Halogen Free Thermoset compound - SHF2 (PJ)
Enclosure - Page 2 of 2
CHJ Series, CHE Series
+Armor:
8: Copper wire braided
9: Steel wire braided
+Outer Sheath:
0: None
2: Thermoplastic Compound - ST2
5: Halogen Free Thermoset Compound - SHF2
6: Halogen Free Thermoplastic Compound - SHF1
+Other properties’ suffix:
CH: Shipboard communication cable
P: Individual screen
+Flammability Code:
SA: Bunched flame retardant cable, comply with IEC 60332-3, IEC 60332-1.
NA: Fire resistant cable, comply with IEC60332-3, IEC 60332-1, IEC60331
SC: Halogen-free Low-smoke bunched flame retardant cable, comply with IEC 60332-3,IEC 60332-1, IEC60754, IEC61034
NC: Halogen-free Low-smoke bunched flame retardant fire resistant cable, comply with IEC 60332-3, IEC 60332-1, IEC60331, IEC 60754, IEC61034
NSC: Halogen-free Low-smoke bunched flame fire resistant cable, comply with IEC 60332-3, IEC 60332-1,IEC60331, IEC 60754, IEC 61034.
2. Reference Documents:
+ Specification of marine power cables. Filed by RINA with drawing No.SHEL-11300.
+ Test Report: “Shanghai Intelligent Service and Technology Co., Ltd” Report No.: TN21-0731E, TN20-4808E, TN20-4809E, TN20-4811E. Filed by RINA with drawing No. SHEL-11303 and SHEL-11304.
+ Routine test Report signed by RINA Surveyor. Filed by RINA with drawing No.SHEL-11302.
+ Asbestos-free Declaration: Filed by RINA with drawing No. SHEL-11299.
3. Notes/Remarks:
+ The product is subject to the compliance with RINA Rules and Standards mentioned on the certificates.
+ Type Approval certifies that a representative sample of the product has been found to meet the applicable design criteria.
+ Any modification or change shall not be valid until approval is granted by RINA as a result of due assessment. |
|